The main task of the steelmaking plant is to desulfurize, dephosphorize, decarburize, and deoxidize the molten iron, and then cast the molten steel into steel billets. The hot rolling plant is an important step in the production of steel bars. It will make the steel embryos through hot rolling or cold rolling again after heating and rolling for several times, and then cut the edge and correct them to finally become steel plates.
Many hot-rolling workshops use relatively old-fashioned metal halide lamps. The lamps have low light efficiency, high power consumption, high failure rate, and large after-sales maintenance. They cannot guarantee the lighting needs of on-site production. In order to solve the lighting problems, our company is based on the actual situation. Summarize and solve the lighting problem of the hot rolling plant from the fundamental problem.
The recommended lighting level in each area of the steel rolling workshop
no. |
workshop and workplace |
average illumination(lux) |
|
1 |
soaking furnace |
furnace top platform and meter room platform |
75 |
slag conveying corridor, platforms on all floors under the furnace, steel ingot car and motorcycle tunnel |
30 |
||
coke powder corridor, coke powder room |
30 |
||
rectifier room |
100 |
||
2 |
heating furnace |
beside heating furnaces such as thin plate, cold drawn, steel pipe workshops, etc., transport hot steel areas |
75 |
push the steel machine |
50 |
||
platforms on each floor of the basement of the heating furnace |
30 |
||
3 |
rolling mill area |
general ground |
75 |
rolling mill, hot saw, shearing machine place |
150 |
||
depress the screw indicator and hole pattern |
300 |
||
on the roller table of the rolling line, on the hot steel conveyor |
150 |
||
cooling bed |
75 |
||
4 |
main electrical room |
electrical room |
200 |
air-duct |
30 |
||
main control room |
500 |
||
5 |
operating room |
300 |
|
6 |
steel billet and finished product warehouse |
on the ground |
75 |
billet cutting location |
100 |
||
grinding machine, billet dressing station and slab pre-selection location |
300 |
||
printing, inspection, precision classification and acceptance |
500 |
||
finished product packaging location |
50 |
||
7 |
oil depot and general transmission basement |
50 |
|
8 |
correction machine |
50 |
|
9 |
spot welding location |
50 |
|
10 |
welding location |
100 |
|
11 |
heat treatment |
annealing |
50 |
pickling room |
100 |
- Slab library
Position Title |
Slab library |
|
The function and role of the post |
Numbering slabs, and stacking different slabs in different areas |
|
On-site characteristics |
Characteristics of building structure |
The plant is relatively spacious |
Features of the equipment |
Main equipment driving |
|
Characteristics of the environment |
Indoor environment, very high temperature, vibration |
|
Lamp requirements |
① The lamp is well sealed and has anti-vibration design. ② Lighting accessories (sealing ring etc. can withstand high temperature). ③ The electrical appliances have high temperature resistance and are easy to use inductive ballasts. ④ It is recommended to use split installation, place the electrical part on the side of the visitor channel, and the principle of hot steam dense area; |
|
Recommended lamps |
The CEX-EX-J explosion-proof LED flood light adopts a sealed structure with high waterproof and anti-corrosion performance. It meets UL1598A marine-level certification. The excellent heat dissipation structure design allows the efficiency and service life of the tube to withstand higher mechanical strength and temperature changes. The power cavity and the light source cavity are separated separately, and the explosion-proof performance is reliable. It is a cost-effective hazardous area floodlight with ATEX\IECEX\UL certification. |
- Heating furnace
Position Title |
Heating furnace |
|
The function and role of the post |
Heat the slab to about 1200 degrees and send it to the rolling line |
|
On-site characteristics |
Characteristics of building structure |
The plant is relatively spacious |
Features of the equipment |
The main equipment is the vaporization cooling heating furnace system. It is mainly divided into: water supplement system, circulation system, sewage system, cooling water system, complex structure, vibration, and part of the equipment is in the basement. |
|
Characteristics of the environment |
Indoor environment, with a lot of steam, very high temperature, humidity, vibration, gas, flammable, explosive and toxic gas. |
|
Lamp requirements |
① The ceiling lamps are sealed to at least IP65, and have anti-vibration and anti-corrosion design. ② Lamp fittings (sealing ring, etc. can withstand high temperature). ③ The lighting equipment close to the furnace body such as corridor lighting, platform lighting, etc. needs to use explosion-proof lamps. ④ Electrical appliances have high temperature resistance and are easy to use inductive ballasts. |
|
Recommended lamps |
CES-EX-LN02 explosion-proof LED linear lamp has extremely sturdy circuit devices and completely sealed electrical components, and has IP66 and WF2 anti-corrosion grades. In addition to being able to withstand severe vibration and vibration, it can also prevent any corrosion that may cause electrical failure . Hazardous areas Linear lights also have multi-voltage capabilities. They can operate under 100-277 VAC, 50/60Hz, without additional special ballasts. |
- Rolling line
Position Title |
Rolling line |
|
The function and role of the post |
Rolling slabs into strips of different thicknesses |
|
On-site characteristics |
Characteristics of building structure |
The plant is relatively spacious |
Features of the equipment |
(Main equipment: dephosphorization box, vertical roll, roughing mill, hot coil box, flying shear, finishing dephosphorization machine, small vertical roll, finishing mill, laminar cooling roller table, underground coiler), there are many links, Continuous operation, vibration. |
|
Characteristics of the environment |
Indoor operations are corrosive and have certain vibrations. The equipment should be flushed with water. |
|
Lamp requirements |
① The ceiling lamps are sealed to at least IP65, and have anti-vibration and anti-corrosion design. ② Electrical appliances have high temperature resistance and are easy to use inductive ballasts. ③ It is recommended to adopt a split installation, and place the electrical part on the side of the visitor channel, where the principle is hot steam dense area. |
|
Recommended lamps |
The internal electrical components of the CEX-EX-LN explosion-proof LED linear lamp are completely sealed and can work underwater (3 meters, we have a long-term hydraulic test and heavy pressure test). The light source room is completely separated from the power source, effectively avoiding electrical sparks. The impact of components or optical components, the hazardous area linear lamp has IP66 waterproof rating, 10mm thick tempered glass + ADC12 and 6063 aluminum housing, shock and vibration resistance, can withstand 7J impact, suitable for salt water and corrosive environments. |
- Finishing
Position Title |
Finishing |
|
The function and role of the post |
1. Reshape the strip. 2. Adjust the length, width, and weight of the strip according to customer needs. |
|
On-site characteristics |
Characteristics of building structure |
The plant is relatively spacious |
Features of the equipment |
Equipment (including uncoiler, straightening machine, cutting machine, hydraulic shears), there is vibration, there are large motors and control parts, there are electric meters for motor operation, etc. There are many occasions where there are camera monitoring. |
|
Characteristics of the environment |
Indoors, it is corrosive, the temperature is high, and there is a certain amount of vibration. |
|
Lamp requirements |
① The ceiling lamps are sealed to at least IP65, and have anti-vibration and anti-corrosion design. ② Lamp fittings (sealing ring, etc. can withstand high temperature). ③ Electrical appliances have high temperature resistance and are easy to use inductive ballasts. ④ It is recommended to adopt a split installation, and place the electrical part on the side of the visitor channel, in an area with dense hot steam. |
|
Recommended lamps |
CES-EX-GB explosion-proof high bay light is a high-power explosion-proof lamp. The flameproof shell design can prevent the electric spark generated in the lamp from being transmitted to the outside. Its protection level is IP66/67, can withstand 7J shock and vibration, and its explosion-proof performance is better than HPS Explosion-proof lamps, metal halide lamps, halogen lamps, etc. are more reliable. The wiring cavity, power supply cavity, light source cavity and other cavities are independently divided into cavities. The explosion-proof performance is reliable and it is very corrosive and high-temperature environment. |
- Curl and pack
Position Title |
Coil library |
|
The function and role of the post |
Roll the flattened steel and pack it out of the warehouse. |
|
On-site characteristics |
Characteristics of building structure |
The steel coil warehouse has a large area. |
Features of the equipment |
The main equipment is a coiler and a crane for packing and storing carbon steel and stainless steel after sorting and sorting. |
|
Characteristics of the environment |
Indoors, the temperature is high and there is a certain amount of vibration. |
|
Lamp requirements |
① The ceiling lamps are sealed to at least IP65, and have anti-vibration and anti-corrosion design. ② Lamp fittings (sealing ring, etc. can withstand high temperature) ③ Electrical appliances have high temperature resistance and are easy to use inductive ballasts. ④ It is recommended to adopt a split installation, and place the electrical part on the side of the visitor channel, in an area with dense hot steam. |
|
Recommended lamps |
The unique installation module design of CES-EX-GB02 explosion-proof high bay light enables the light to achieve 90-degree aiming and efficient ballast. The device has EOL protection function, which can eliminate potential accidents. Each cavity, such as the wiring cavity, the power supply cavity and the light source cavity, is independently divided into cavities, and the explosion-proof performance is reliable. The IP66/67 protection level, durability, anti-vibration and impact resistance make the lamp more efficient and safer. |
- Roller repair room
Position Title |
Roller room |
|
The function and role of the post |
Check and trim the accuracy of rolls, store all kinds of rolls |
|
On-site characteristics |
Characteristics of building structure |
The workshop is spacious. |
Features of the equipment |
The main equipment is driving. |
|
Characteristics of the environment |
Indoors, there is a certain amount of vibration. |
|
Lamp requirements |
① The ceiling lamps are well sealed and have anti-vibration design. ② It is recommended to use split installation, and place the electrical part on the side of the visitor channel to reduce the weight of the lamp. |
|
Recommended lamps |
The CES-EX-SF explosion-proof LED canopy lamp has a sturdy shell, and the internal electrical components are completely sealed. It has the characteristics of impact resistance, vibration resistance and corrosion resistance. The PC mask diffuses to reduce glare, can withstand 6J pressure, and the maximum temperature does not exceed T4, which is much lower than the traditional The temperature of the lamp. Energy efficiency is 80% higher than that of metal halides. The service life is up to 50,000 hours, making it maintenance-free for almost many years. |
- Electrical room
Position Title |
Electrical room |
|
The function and role of the post |
The control center of electric equipment such as motors in the hot rolling area. |
|
On-site characteristics |
Characteristics of building structure |
Spacious workshop |
Features of the equipment |
The main equipment is electrical cabinets and control cabinets. |
|
Characteristics of the environment |
Indoor, conventional environment. |
|
Lamp requirements |
① No special requirements. ② Conventional fluorescent lamps or ceiling lamps can satisfy lighting requirements without glare. ③ The choice of lamp type depends on the structure and height of the workshop plant. |
|
Recommended lamps |
CES-EX-LN-02P explosion-proof linear light design replaces the traditional explosion-proof fluorescent lamp, explosion-proof tri-proof lamp, anti-glare-micro optics can reduce direct visual contact with the light source. The slim and streamlined design of linear lights in hazardous areas allows access to limited spaces at a low installation height, and is IP66 waterproof and dustproof, with a life span of more than 50,000 hours. |
Shenzhen CESP Co., Ltd. focuses on the field of special industrial lighting. It is a high-tech enterprise integrating design, R&D, production and sales. The complete management team covers the lighting fields of China's electric power, metallurgy, oil refining, railways, large industrial and mining enterprises, marine ships, etc. Provide professional lighting supporting solutions, and also provide advanced technical support and product supporting services for internationally renowned companies.
At the same time, CESP is also ATEX certified led manufacturer, UL led manufacturers and IECEX certified led supplier. The company’s products include explosion proof LED flood light, explosion proof led highbay light, explosion proof led canopy light, explosion proof led linear light, explosion proof portable hand light etc. If you have explosion-proof lighting needs, you can click on the page to contact us, or call our hotline +86-755-83509822.