Explosion Proof LED Linear Light - Ex d Zone 1 Zone 21 - 50W 60W 80W 100W

0.6m Length, Flameproof Type, IECEx ATEX Certificated, Zone 1, Ex db op is IIC T5/T6 Gb, Zone 21, Ex tb op is IIC T94°C/T89°C/T84°C

 

Applications:

• Wastewater treatment,oil and gas refineries, drilling rigs, petrochemical facilities, food and beverage facilities, tunnels, outdoor wall and stanchion mounted general area lighting, and where flammable vapors, gases, ignitable dusts, fibers or flyings are present.
• Applies to hazardous locations of Zone 1 and Zone2 with explosive gas atmosphere.
• Applies to hazardous locations of Zone 21 and Zone22 with explosive dust atmosphere.

ATEX: EN IEC 60079-0-2018 ; EN 60079-1-2014; EN 60079-28-2015; EN 60079-31-2014;
IECEx: IEC 60079-0-2017; IEC 60079-1-2014; IEC 60079-28-2015; IEC 60079-31-2013;

IECEx & ATEX :

  • “CAUTION-USEFASTENER WITH YIELD STRESS ≥ 640 MPa”;
  • “WARNING – DO NOT OPEN WHEN ENERGIZED”;
  • “WARNING – DO NOT OPEN WHEN AN EXPLOSIVE ATMOSPHERE IS PRESENT”;
  • “WARNING – ONLY USE CABLES SUITABLE FOR 85°C”;
  • " WARNING - DETAILED TEMPERATURE CLASS - SEE INSTRUCTIONS”;
  • “THE FLAMPROOF JOINTS ARE NOT INTENDED TO BE REPAIRED”;
  • End user shall use certified cable gland or conduit with suitable type of protection for final installation purpose;
  • External earthing wire shall be connected when used and the cross-sectional areashall be more than 4mm2 or 10AWG;
  • Under rating condition, maximum temperature on the luminaire’s shell shall not be higher than 130℃ for T4.Temperature at cable inlet shall not be higher than allowable limit of the cable applied, to ensure the cable operation normally. The branch point is 83.6℃ and cable entry point is 69.4℃

Features

  • Industry-leading efficacy: 130lm/W±5
  • -40°C to +45°C /50°C /55°CAmbient operating temperature
  • Mounting: U-bracket
  • Wide optics for uniform illumination
  • 5 years warranty
  • Entry Size: M25Χ1.5 or NPT 3/4”-14
  • Housing –Aluminum alloy (ADC12 )
  • Lens – tempered glass (10mm)
  • Beam angle: 8°, 15°, 35°, 60°, 90°, 120°

Parameters

  •  Power: 50W / 60W / 80W/ 100W
  •  Input voltage: AC100-240/277V, 50/60Hz
  •  Power factor: 0.97
  •  Lumen flux: 6000LM / 7200LM / 9600LM / 12000LM
  •  CCT: 2700K - 6500K (Optional)
  •  LEDs: 3030 / 3535
  •  LED Driver: Meanwell HLG series
  •  Dimension: 617mm x 155mm x 148mm
  •  Weight: 11.4KG

Certificate & Standard

Have certified CES-EX-LN fixtures with the IECEX and ATEX standards for hazardous location and environments.

ATEX:
  • II 2G Ex db op is IIC T5…T6 Gb
  • II 2D Ex tb op is IIIC T94°C…T89°C …T84°C Db
  • IP66
  • Certificate No:SEV 19 ATEX 0332 X
IECEx:
  • Ex db op is IIC T5…T6 Gb
  • Ex tb op is IIIC T94°C…T89°C …T84°C Db
  • IP66
  • Certificate No:IECEx SEV 19.0039

Amounting

Versatile mounting options:

  • Flush mount
  • Swivel/surface mount
  • Pole mount
  • Mounting Angle:0°to ±90°;

 