IECEx ATEX Certified Explosion proof LED Lights - Zone 1 Zone 2 Hazardous Area Lighting

CESP Zone 1 Zone 2 hazardous location LED lights are in accordance with International Protection Techniques (Equipment Protection Levels), including IEC/EN 60079-0 (General Requirement), IEC/EN 60079-1 (Flameproof Enclosure), IEC/EN 60079-7 (Increased Safety), IEC/EN 60079-11 (Intrinsic Safety), IEC/EN 60079-15 (Type of Protection), IEC/EN 60079-18, IEC/EN 60079-28, IEC/EN 60079-31. If you are not sure about the Classified of your lighting application environment, please contact our technical department for the solution.
 

For Zone 1 Zone 2, Zone 21 Zone 22 hazardous area led lighting, 20W - 200W, 130lm/W,aluminum alloy + 8mm tempered glass, multi-installation for different projects, such as light tower, canopy light, marine grade.

Flameproof enclosure, Ex db op is IIC T6 Gb, Zone 1 & Zone 21 with explosive gas atmosphere, Zone 21 and Zone22 with explosive dust atmosphere, 10mm temered glass, 7J impact resistance,up to 26000lm.

Flameproof enclosure, Ex db op is IIC T6 Gb, IP68 protection grade, tempered glass 10mm, withstand impacts up to 10J, 2 foot and 4 foot Length, 50Watt- 240Watt, 130lm/W light efficacy.

Zone 1 & Zone 21, 1ft, 2ft, 3ft, 4ft length can be selected, replace the traditional explosion-proof three-proof lamp, explosion-proof fluorescent tube, anti-corrosion, anti-glare, anti-drop, competitive price.

Flameproof LED hand lamp for Zone 1 & Zone 21 hazardous areas, 10mm tempered glass, pass the multi-angle drop test, 10W, 20W, 30W Power, can be connected to the cable, emergency power box.

The CES-EX-SF series explosion-proof ceiling lamp has a strong shell, with features such as impact resistance, vibration resistance, and corrosion resistance. It can be used in hazardous environments of Zone 1&21, Zone 2&22.

CES-EX-JX Series is your go-to solution for illuminating hazardous Zone 1 and Zone 21 areas. With ATEX approval, these Explosion-proof LED Flood Lights offer unbeatable safety standards.

Discover the pinnacle of safety and illumination with our CES-EX-GBX Series Explosion-proof LED High Bay Lights. Designed for hazardous Zone 1 and Zone 21 areas, these lights boast ATEX approval, ensuring the highest safety standards.

GB-02 explosion-proof lights are made of alloy aluminum and tempered glass, with shock resistance and anti-vibration performance. The luminaires have passed the ATEX IECEx standards test, from 30W to 80W for hazardous area lighting.

LN-02 explosion-proof lights obtained an IECEx ATEX certificate, it's safe for the Zone 1 and Zone 2 hazardous locations. The copper-free aluminum alloy body is powder-coated to increase durability and beautiful appearance, are able to withstand violent shaking and shock resistance.

an innovative line of LED hazardous area lighting products, specifically designed for use in potentially explosive atmospheres (Zone 1/21 & 2/22) within harsh industrial settings such as coal mines and oil & gas facilities.

Explosion-proof safety exit lamps are for personnel evacuation, and fire operations to provide lighting fire emergency lamps! It usually uses an external power supply, when the power automatically switches to the battery power state!

 

Luminaires: CES-EX-LN-02P, 2FT Class 1 Div 2 LED Light, UL844 Hazardous Loction Approved.

Location: United State.

 

The control room is the command center for production scheduling of the whole plant. The staff can obtain information through various monitoring equipment for scheduling instructions. It is a densely populated area. Working for a long time, especially late at night, people is easy to lose concentration, quality comfortable lighting environment is conducive to relieve visual fatigue, concentration. Considering the environmental characteristics of the central control room and the need for green lighting, we generally recommend CES-EX-LN-02P ceiling-mounted line lights to provide lighting for the central control room. The explosion-proof lights uses a new generation of high brightness LED light source, light efficiency up to 120lm/W, high efficiency, energy saving, uniform light, no stabs, using PC cover can also be anti-glare, good visual effect, conducive to the work site to create a comfortable light environment.

If you need to Dialux Lighting Solution for your control room, please provide us with the CAD drawings, or the dimensions of the room.

 

 

Published in Our Cases

Explosion Proof LED Linear Light - ATEX IECEx Zone 1 Zone 2 - 200W 240W 300W

 

Applications

Wastewater treatment,oil and gas refineries, drilling rigs, petrochemical facilities, food and beverage facilities, tunnels, outdoor wall and stanchion mounted general area lighting, and where flammable vapors, gases, ignitable dusts, fibers or flyings are present.

Standard :
ATEX: EN IEC 60079-0-2018; EN 60079-7-2015; EN 60079-31-2014;
IECEx: IEC 60079-0-2017; IEC 60079-7-2015; IEC 60079-31-2013;

Warning

IECEx& ATEX :

  • “WARNING – DO NOT OPEN WHEN ENERGIZED”;
  • “WARNING – DO NOT OPEN WHEN AN EXPLOSIVE ATMOSPHERE IS PRESENT”;
  • “WARNING – Potential Electrostatic Charging Hazard –Please wipe with a damp cloth when cleaning”;
  • End user shall use certified cable gland suitable type of protection for final installation purpose;
  • External earthing wire shall be connected when used and the cross-sectional area shall be more than 4mm²or 10AWG;
  • Under rating condition, maximum temperature on the luminaire’s shell shall not be higher than 165℃ for T3. Temperature at cable inlet shall not be higher than allowable limit of the cable applied, to ensure the cable operation normally. For CES-EX-LN-02-80、CES-EX-LN-02-100、CES-EX-LN-02-120、CES-EX-LN-02-150, the branch point is 78.4℃ and cable entry point is 66.8℃

Features

  • Luminous flux: 26000LM / 31200LM / 39000LM
  • -40°C to + 50°C Ambient operating temperature
  • 5 years warranty
  • Entry Size: M25 X 1.5
  • Housing – Aluminum alloy (ADC12 and 6063)
  • Lens – Tempered glass
  • LED Driver: Meanwell HLG series

Parameters

  • Power: 200W / 240W / 300W
  • Input voltage: AC100-240/277V, 50/60Hz
  • Power factor: 0.97
  • Light efficacy: 120 - 140lm/W
  • CCT: 3000K/4000K/5000K/5700K/6500K
  • LEDs: 3030
  • Bean angle: 90° or 110°
  • Dimension: 564*202*112mm (Single Fixture)
  • Weight: 10.6KG

Certificate & Standard

IECEx Certificate No. :  IECEx UL 22.0091X

  •  Ex ec IIC T *Gc
  •  Ex tb IIIC T *°C Db
  •  IP66

IECEx Certificate No. : ATEX Certificate No.: UL 22 ATEX 2543X, UL 22 ATEX 2544X

  •  II 3G Ex ec IIC T*Gc
  •  II 2D Ex tb IIIC T*Db
  •  IP66

Mounting

Versatile mounting options:

  • Ceiling mount
  • Drop mount
  • Wall Mount
  • Mounting Angle:0°to ±90°

Explosion Proof LED Linear Light - ATEX IECEx Zone 1 Zone 2 - 80W 100W 120W 150W

 

Applications

Wastewater treatment,oil and gas refineries, drilling rigs, petrochemical facilities, food and beverage facilities, tunnels, outdoor wall and stanchion mounted general area lighting, and where flammable vapors, gases, ignitable dusts, fibers or flyings are present.

Standard :
ATEX: EN IEC 60079-0-2018; EN 60079-7-2015; EN 60079-31-2014;
IECEx: IEC 60079-0-2017; IEC 60079-7-2015; IEC 60079-31-2013;

Warning

IECEx& ATEX :

  • “WARNING – DO NOT OPEN WHEN ENERGIZED”;
  • “WARNING – DO NOT OPEN WHEN AN EXPLOSIVE ATMOSPHERE IS PRESENT”;
  • “WARNING – Potential Electrostatic Charging Hazard –Please wipe with a damp cloth when cleaning”;
  • End user shall use certified cable gland suitable type of protection for final installation purpose;
  • External earthing wire shall be connected when used and the cross-sectional area shall be more than 4mm²or 10AWG;
  • Under rating condition, maximum temperature on the luminaire’s shell shall not be higher than 165℃ for T3. Temperature at cable inlet shall not be higher than allowable limit of the cable applied, to ensure the cable operation normally. For CES-EX-LN-02-80、CES-EX-LN-02-100、CES-EX-LN-02-120、CES-EX-LN-02-150, the branch point is 78.4℃ and cable entry point is 66.8℃

Features

  • Luminous flux: 10400LM / 13000LM / 15600LM / 19500LM
  • -40°C to +50°C Ambient operating temperature
  • 5 years warranty
  • Entry Size: M25 X 1.5
  • Housing – Aluminum alloy (ADC12 and 6063)
  • Lens – tempered glass
  • LED Driver: Meanwell HLG series

Parameters

  • Power:80W/100W/120W / 150W
  • Input voltage: AC100-240/277V, 50/60Hz
  • Power factor: 0.97
  • Light efficacy: 120 - 140lm/W
  • CCT: 3000K/4000K/5000K/5700K/6500K
  • LEDs: 3030
  • Bean angle: 90° or 110°
  • Dimension: 564*202*112mm
  • Weight: 10.6KG

Certificate & Standard

IECEx Certificate No. :  IECEx UL 22.0091X

  •  Ex ec IIC T *Gc
  •  Ex tb IIIC T *°C Db
  •  IP66

IECEx Certificate No. : ATEX Certificate No. : UL 22 ATEX 2543X, UL 22 ATEX 2544X

  •  II 3G Ex ec IIC T*Gc
  •  II 2D Ex tb IIIC T*Db
  •  IP66

Mounting

Versatile mounting options:

  • Ceiling mount
  • Drop mount
  • Wall Mount
  • Mounting Angle:0°to ±90°

Explosion Proof LED Linear Light - ATEX IECEx Zone 1 Zone 2 - 40W 50W 60W

 

Applications

Wastewater treatment,oil and gas refineries, drilling rigs, petrochemical facilities, food and beverage facilities, tunnels, outdoor wall and stanchion mounted general area lighting, and where flammable vapors, gases, ignitable dusts, fibers or flyings are present.

Standard :
ATEX: EN IEC 60079-0-2018; EN 60079-7-2015; EN 60079-31-2014;
IECEx: IEC 60079-0-2017; IEC 60079-7-2015; IEC 60079-31-2013;

Warning

IECEx& ATEX :

  • “WARNING – DO NOT OPEN WHEN ENERGIZED”;
  • “WARNING – DO NOT OPEN WHEN AN EXPLOSIVE ATMOSPHERE IS PRESENT”;
  • “WARNING – Potential Electrostatic Charging Hazard –Please wipe with a damp cloth when cleaning”;
  • End user shall use certified cable gland suitable type of protection for final installation purpose;
  • External earthing wire shall be connected when used and the cross-sectional area shall be more than 4mm²or 10AWG;
  • Under rating condition, maximum temperature on the luminaire’s shell shall not be higher than 165℃ for T3. Temperature at cable inlet shall not be higher than allowable limit of the cable applied, to ensure the cable operation normally. For CES-EX-LN-02-40、CES-EX-LN-02-50、CES-EX-LN-02-60, the branch point is 61.8℃ and cable entry point is 57.5℃.
 

Features

  • Luminous flux: 5200LM / 6500LM / 7800LM
  • -40°C to +50°C Ambient operating temperature
  • 5 years warranty
  • Entry Size: M25 X 1.5
  • Housing –Aluminum alloy (ADC12 and 6063)
  • Lens –tempered glass
  • LED Driver: Meanwell HLG series

Parameters

  • Power:40W/50W/60W
  • Input voltage: AC100-240/277V, 50/60Hz
  • Power factor: 0.97
  • Light efficacy: 120 - 140lm/W
  • CCT: 3000K/4000K/5000K/5700K/6500K
  • LEDs: 3030
  • Bean angle: 90° or 110°
  • Dimension: 596*126*114mm
  • Weight: 7.5KG

Certificate & Standard

IECEx Certificate No. :  IECEx UL 22.0091X

  •  Ex ec IIC T *Gc
  •  Ex tb IIIC T *°C Db
  •  IP66

IECEx Certificate No. : ATEX Certificate No. : UL 22 ATEX 2543X, UL 22 ATEX 2544X

  •  II 3G Ex ec IIC T*Gc
  •  II 2D Ex tb IIIC T*Db
  •  IP66

Mounting

Versatile mounting options:

  • Ceiling mount
  • Drop mount
  • Wall Mount
  • Mounting Angle:0°to ±90°

Luminaires: CES-EX-LN-02P, 2 Feet explosion proof linear lights

Italy - these luminaries are installed in explosion-proof boxes

 

Explosion-proof box is generally used in the hazardous area of gas explosion or dust explosion environment, so the explosion-proof box itself uses explosion-proof structure. For the second area, in accordance with common sense, the electrical components inside the explosion-proof box (online monitoring instruments, distribution box equipment,) do not need to explosion-proof function, but in the use and maintenance process if the internal electrical components are ordinary, it will cause great difficulties in the maintenance and repair of the equipment.

For example, in the normal operation of the explosion-proof box, suddenly there is a problem in the online monitoring equipment, maintenance personnel need to enter the internal maintenance, then the explosion-proof box needs to be treated with power off, after the power off the air conditioning system in the box, lighting system will lose effect, in the hot summer or night maintenance is very inconvenient, so the explosion-proof box is best made of internal and external explosion-proof type.

 

Published in Our Cases

Luminaires: CES-EX-LN-02P

2ft explosion proof linear light used for the shipping container.

For the project, a total of 12 containers, with 6 lamps installed in each container.

If you would like to know more, please contact us any time.

Published in Our Cases

Testing!!! in Singapore.


EX-proof Fluorescent lamp VS CES-EX-LN-02P-40 Ex-proof linear luminaries.

 explosion proof lights

Published in Our Cases

Hazardous Location LED Linear Light - Combination Installation - 160W 200W 240W 300W

 

Applications

Wastewater treatment,oil and gas refineries, drilling rigs, petrochemical facilities, food and beverage facilities, tunnels, outdoor wall and stanchion mounted general area lighting, and where flammable vapors, gases, ignitable dusts, fibers or flyings are present.

Warning

CUL for Hazloc:

  • SUITABLE FOR WET LOCATIONS;
  • THIS LUMINAIRE IS ACCEPTABLE FOR OPERATION IN AMBIENT CONDITIONS NOT EXCEEDING 50°C;
  • FOR SUPPLY CONNECTION, USE WIRES RATED FOR AT LEAST90°C;
  • NO SERVICEABLE PARTS” OR “NO USER SERVICEABLE PARTS. DO NOT OPEN FOR CLEANING.;
  • CAUTION - ″TO REDUCE THE RISK OF IGNITION OF HAZARDOUS ATMOSPHERES, DISCONNECT THE LUMINAIRE FROM THE SUPPLY CIRCUIT BEFORE OPENING. KEEP TIGHTLY CLOSED WHEN IN OPERATION.″;
  • THIS PRODUCT MUST BE INSTALLED IN ACCORDANCE WITH THE APPLICABLE INSTALLATION CODE BY A PERSON FAMILIAR WITH THE CONSTRUCTION AND OPERATION OF THE PRODUCT AND THE HAZARDS INVOLVED;
  • CAUTION – RISK OF SHOCK” and “DISCONNECT POWER BEFORE SERVICING”.
 

Features

  • Luminous flux: 19200LM / 24000LM / 28800LM / 36000LM
  • -40°C to +50°C Ambient operating temperature
  • Wide optics for uniform illumination
  • 5 years warranty
  • Entry Size: NPT 3/4”-14 ;
  • Housing –Aluminum alloy (ADC12 and 6063)
  • Lens –tempered glass

Parameters

  • Power:160W / 200W / 240W / 300W
  • Input voltage: AC100-240/277V, 50/60Hz
  • Power factor: 0.97
  • Light efficacy: 120 - 140lm/W
  • CCT: 3000K/4000K/5000K/5700K/6500K
  • LEDs: 3030 (6V)
  • LED Driver: Meanwell HLG series
  • Weight: 21.2KG

Certificate & Standard

Have certified CES-EX-LN-02 fixtures with the NEC and CEC standards for hazardous location and environments

  •  Class I, Division 2, Groups A, B, C and D;
  •  Class II, Division 2, Groups F and G
  •  Class III
  •  T-Class: T *(T3C/T4A/T5)
  •  Wet Location

Certificate No:E475887
US: UL 844; UL 1598; 
Canada: CSA C22.2 No. 137; CSA C22.2 No. 250.0

 

Mounting

Versatile mounting options:

  • Ceiling mount
  • Mounting Angle:0°to ±90°
  • When installing in ignitable dusts, fibers or flyings, do not allow the lamp cover to be installed upwards.

Hazardous Location LED Linear Light - Class 1 Division 2 - 80W 100W 120W 150W

 

Applications

Wastewater treatment,oil and gas refineries, drilling rigs, petrochemical facilities, food and beverage facilities, tunnels, outdoor wall and stanchion mounted general area lighting, and where flammable vapors, gases, ignitable dusts, fibers or flyings are present.

When installing models CES-EX-LN-02-150, CES-EX-LN-02-120, CES-EX-LN-02-100, CES-EX-LN-02-80 in ignitable dusts, fibers or flyings, do not allow the lamp cover to be installed upwards.

Warning

CUL for Hazloc:

  • SUITABLE FOR WET LOCATIONS;
  • THIS LUMINAIRE IS ACCEPTABLE FOR OPERATION IN AMBIENT CONDITIONS NOT EXCEEDING 50°C;
  • FOR SUPPLY CONNECTION, USE WIRES RATED FOR AT LEAST90°C;
  • NO SERVICEABLE PARTS” OR “NO USER SERVICEABLE PARTS. DO NOT OPEN FOR CLEANING.;
  • CAUTION - ″TO REDUCE THE RISK OF IGNITION OF HAZARDOUS ATMOSPHERES, DISCONNECT THE LUMINAIRE FROM THE SUPPLY CIRCUIT BEFORE OPENING. KEEP TIGHTLY CLOSED WHEN IN OPERATION.″;
  • THIS PRODUCT MUST BE INSTALLED IN ACCORDANCE WITH THE APPLICABLE INSTALLATION CODE BY A PERSON FAMILIAR WITH THE CONSTRUCTION AND OPERATION OF THE PRODUCT AND THE HAZARDS INVOLVED;
  • CAUTION – RISK OF SHOCK” and “DISCONNECT POWER BEFORE SERVICING”.
 

Features

  • Luminous flux: 10400LM / 13000LM / 15600LM / 19500LM
  • -40°C to +50°C Ambient operating temperature
  • Wide optics for uniform illumination
  • 5 years warranty
  • Entry Size: NPT 3/4”-14 ;
  • Housing –Aluminum alloy (ADC12 and 6063)
  • Lens –tempered glass

Parameters

  • Power:80W / 100W / 120W / 150W
  • Input voltage: AC100-240/277V, 50/60Hz
  • Power factor: 0.97
  • Light efficacy: 120 - 140lm/W
  • CCT: 3000K/4000K/5000K/5700K/6500K
  • LEDs: 3030 (6V)
  • LED Driver: Meanwell HLG series
  • Dimension: 564 mmx202mmx112mm
  • Weight: 10.6KG

Certificate & Standard

Have certified CES-EX-LN-02 fixtures with the NEC and CEC standards for hazardous location and environments

  •  Class I, Division 2, Groups A, B, C and D;
  •  Class II, Division 2, Groups F and G
  •  Class III
  •  T-Class: T *(T3C/T4A/T5)
  •  Wet Location

Certificate No:E475887
US: UL 844; UL 1598
Canada: CSA C22.2 No. 137; CSA C22.2 No. 250.0

 

Mounting

Versatile mounting options:

  • Ceiling mount
  • Drop mount
  • Wall Mount
  • Mounting Angle:0°to ±90°

Hazardous Location LED Linear Light - Class 1 Division 2 - 40W 50W 60W

 

Applications

Wastewater treatment,oil and gas refineries, drilling rigs, petrochemical facilities, food and beverage facilities, tunnels, outdoor wall and stanchion mounted general area lighting, and where flammable vapors, gases, ignitable dusts, fibers or flyings are present.

Warning

CUL for Hazloc:

  • SUITABLE FOR WET LOCATIONS;
  • THIS LUMINAIRE IS ACCEPTABLE FOR OPERATION IN AMBIENT CONDITIONS NOT EXCEEDING 50°C;
  • FOR SUPPLY CONNECTION, USE WIRES RATED FOR AT LEAST90°C;
  • NO SERVICEABLE PARTS” OR “NO USER SERVICEABLE PARTS. DO NOT OPEN FOR CLEANING.;
  • CAUTION - ″TO REDUCE THE RISK OF IGNITION OF HAZARDOUS ATMOSPHERES, DISCONNECT THE LUMINAIRE FROM THE SUPPLY CIRCUIT BEFORE OPENING. KEEP TIGHTLY CLOSED WHEN IN OPERATION.″;
  • THIS PRODUCT MUST BE INSTALLED IN ACCORDANCE WITH THE APPLICABLE INSTALLATION CODE BY A PERSON FAMILIAR WITH THE CONSTRUCTION AND OPERATION OF THE PRODUCT AND THE HAZARDS INVOLVED;
  • CAUTION – RISK OF SHOCK” and “DISCONNECT POWER BEFORE SERVICING”.
 

Features

  • Luminous flux: 5200LM / 6500LM / 7800LM
  • -40°C to +50°C ambient operating temperature
  • Wide optics for uniform illumination
  • 5 years warranty
  • Entry Size: NPT 3/4”-14 ;
  • Housing –Aluminum alloy (ADC12 and 6063)
  • Lens –tempered glass

Parameters

  • Power:40W/50W/60W
  • Input voltage: AC100-240/277V, 50/60Hz
  • Power factor: 0.97
  • Light efficacy: 120 - 140lm/W
  • CCT: 3000K/4000K/5000K/5700K/6500K
  • LEDs: 2835
  • LED Driver: Meanwell HLG series
  • Dimension: 596*126*114mm
  • Weight: 7.5KG

Certificate & Standard

Have certified CES-EX-LN-02 fixtures with the NEC and CEC standards for hazardous location and environments

  •  Class I, Division 2, Groups A, B, C and D;
  •  Class II, Division 2, Groups F and G
  •  Class III
  •  T-Class: T *(T3C/T4A/T5)
  •  Wet Location
Certificate No:E475887
US: UL 844; UL 1598
Canada: CSA C22.2 No. 137; CSA C22.2 No. 250.0

Mounting

Versatile mounting options:

  • Ceiling mount
  • Drop mount
  • Wall Mount
  • Mounting Angle:0°to ±90°