Zone 21 Explosion Proof LED Light  - ATEX IECEx - 60W 80W

 

Applications

Wastewater treatment,oil and gas refineries, drilling rigs, petrochemical facilities, food and beverage facilities, tunnels, outdoor wall, and stanchion mounted general area lighting, and where flammable vapors, gases, ignitable dusts, fibers or flyings are present.

Standard :
ATEX: EN IEC 60079-0-2018; EN 60079-7-2015; EN 60079-31-2014;
IECEx: IEC 60079-0-2017; IEC 60079-7-2015; IEC 60079-31-2013;

Warning

IECEx& ATEX :

  • “WARNING – DO NOT OPEN WHEN ENERGIZED”;
  • “WARNING – DO NOT OPEN WHEN AN EXPLOSIVE ATMOSPHERE IS PRESENT”;
  • “WARNING – Potential Electrostatic Charging Hazard –Please wipe with a damp cloth when cleaning”;
  • End user shall use certified cable gland suitable type of protection for final installation purpose;
  • External earthing wire shall be connected when used and the cross-sectional area shall be more than 4mm² or 10AWG;
  • Under rating condition, maximum temperature on the luminaire’s shell shall not be higher than 130℃ for T4. Temperature at cable inlet shall not be higher than allowable limit of the cable applied, to ensure the cable operation normally. For CES-EX-GB-02-60、CES-EX-GB-02-80,The branch point is 58.2℃ and cable entry point is 52.6℃;

Features

  • Luminous flux: 7800lm / 10400lm
  • -40°C to +50°C ambient operating temperature
  • Wide optics for uniform illumination
  • 5 years warranty
  • Entry Size: M25 * 1.5
  • Housing – Aluminum alloy (ADC12)
  • Lens – tempered glass
  • Dimension: 300*204mm
  • Weight: 7KG

Parameters

  • Power: 60W / 80W
  • Input voltage: AC100-240/277V, 50/60Hz
  • Power factor: 0.97
  • Light efficacy: 120 - 140lm/W
  • CCT: 3000K/4000K/5000K/5700K/6500K
  • LEDs: 3030
  • LED Driver: Meanwell HBG series

Certificate & Standard

Certifications and compliances for hazardous location.

  • IECEx Certificate No. :  IECEx UL 22.0091X
    • Ex ec IIC T *Gc
    • Ex tb IIIC T *°C Db;
    • IP66;

  • ATEX Certificate No. :  UL 22 ATEX 2543X, UL 22 ATEX 2544X
    • II 3G Ex ec IIC T*Gc;
    • II 2D Ex tb IIIC T*Db;
    • IP66;

Mounting

Versatile mounting options:

  • Ceiling mount
  • Pole mount

Related items

  • Explosion Proof High Bay LED Light 240W - 300W
  • Explosion Proof High Bay LED Light 120W - 200W
  • Explosion Proof High Bay LED Light 60W - 100W
  • Explosion Proof High Bay LED Light 30W - 50W
  • Explosion Proof LED Light - IECEx ATEX Zone 21 - 30W 40W

    Zone 21 Explosion Proof LED Light  - ATEX IECEx - 30W 40W

     

    Applications

    Wastewater treatment,oil and gas refineries, drilling rigs, petrochemical facilities, food and beverage facilities, tunnels, outdoor wall, and stanchion mounted general area lighting, and where flammable vapors, gases, ignitable dusts, fibers or flyings are present.

    Standard :
    ATEX: EN IEC 60079-0-2018; EN 60079-7-2015; EN 60079-31-2014;
    IECEx: IEC 60079-0-2017; IEC 60079-7-2015; IEC 60079-31-2013;

    Warning

    IECEx& ATEX :

    • “WARNING – DO NOT OPEN WHEN ENERGIZED”;
    • “WARNING – DO NOT OPEN WHEN AN EXPLOSIVE ATMOSPHERE IS PRESENT”;
    • “WARNING – Potential Electrostatic Charging Hazard –Please wipe with a damp cloth when cleaning”;
    • End user shall use a certified cable gland suitable type of protection for final installation purpose;
    • External earthing wire shall be connected when used and the cross-sectional area shall be more than 4mm² or 10AWG;
    • Under rating conditions, the maximum temperature on the luminaire’s shell shall not be higher than 130℃ for T4. Temperature at cable inlet shall not be higher than allowable limit of the cable applied, to ensure the cable operation normally. For CES-EX-GB-02-30、CES-EX-GB-02-40,The branch point is 57.3℃ and the cable entry point is 52.3℃.

    Features

    • Luminous flux: 3900lm / 5200lm
    • -40°C to +50°C ambient operating temperature
    • Wide optics for uniform illumination
    • 5 years warranty
    • Entry Size: M25*1.5
    • Housing – Aluminum alloy (ADC12)
    • Lens – tempered glass
    • Dimension: 200*157mm
    • Weight: 3KG

    Parameters

    • Power: 30W / 40W
    • Input voltage: AC100-240/277V, 50/60Hz
    • Power factor: 0.97
    • Light efficacy: 120 - 140lm/W
    • CCT: 3000K/4000K/5000K/5700K/6500K
    • LEDs: 3030
    • LED Driver: Meanwell HBG series

    Certificate & Standard

    Certifications and compliances for hazardous location.

    • IECEx Certificate No. :  IECEx UL 22.0091X
      • Ex ec IIC T *Gc
      • Ex tb IIIC T *°C Db;
      • IP66;

    • ATEX Certificate No. :  UL 22 ATEX 2543X, UL 22 ATEX 2544X
      • II 3G Ex ec IIC T*Gc;
      • II 2D Ex tb IIIC T*Db;
      • IP66;

    Mounting

    Versatile mounting options:

    • Ceiling mount
    • Pole mount
     
  • Marine Lighting - Anti-corrosion & Anti-explosive - UL1598A Listed for Marine

    Marine Lighting | Corrosion Prevention | Explosion Prevention |  Zone 1 Zone 21 | 100W 120W 150W 180W 200W |

     

    CESP marine-grade lights comply with China Classification Society (CCS) standards and have obtained UL1598A marine certificate. They can be used for the most demanding exterior lighting marine environments, including sea bridges, offshore drilling platforms, ships, seaside refineries, seaside shipyards, docks, or other acid rain, seawater and salt spray corrosive environments.

    Product process:

    CESP marine-grade LED lighting fixtures, through electrophoresis technology, are coated with a non-metallic paint-like coating on the surface of the lamp body, which makes the appearance of the lamp flat, smooth, corrosion-resistant and impact-resistant. Then, apply multiple coats of marine anti-corrosion paint to enhance corrosion resistance. In addition, the mounting brackets and accessories are made of 304 stainless steel to protect the lamps and lanterns from long-term harsh salt water and atmospheric corrosion in the marine environment.

    Remark: Electrophoresis (EP) is the abbreviation of electrophoresis, which refers to the phenomenon in which charged particles move toward electrodes with opposite electrical properties under the action of an electric field. The technology that uses charged particles to move at different speeds in an electric field to achieve separation is called electrophoresis.

     

    Explosion-proof standard:

    Applies to hazardous locations of Zone 1 and Zone2 with explosive gas atmosphere, and hazardous locations of Zone 21 and Zone22 with explosive dust atmosphere.

    ATEX: EN IEC 60079-0-2018; EN 60079-1-2014; EN 60079-28-2015; EN 60079-31-2014;
    IECEx: IEC 60079-0-2017; IEC 60079-1-2014; IEC 60079-28-2015; IEC 60079-31-2013;

    IECEx & ATEX :

    • “CAUTION-USEFASTENER WITH YIELD STRESS ≥ 640 MPa”;
    • “WARNING – DO NOT OPEN WHEN ENERGIZED”;
    • “WARNING – DO NOT OPEN WHEN AN EXPLOSIVE ATMOSPHERE IS PRESENT”;
    • “WARNING – ONLY USE CABLES SUITABLE FOR 85°C”;
    • " WARNING - DETAILED TEMPERATURE CLASS - SEE INSTRUCTIONS”;
    • “THE FLAMPROOF JOINTS ARE NOT INTENDED TO BE REPAIRED”;
    • End user shall use certified cable gland or conduit with suitable type of protection for final installation purpose;
    • External earthing wire shall be connected when used and the cross-sectional areashall be more than 4mm2 or 10AWG;
    • Under rating condition, maximum temperature on the luminaire’s shell shall not be higher than 130℃ for T4.Temperature at cable inlet shall not be higher than allowable limit of the cable applied, to ensure the cable operation normally. The branch point is 83.6℃ and cable entry point is 69.4℃

    Features

    • Industry-leading efficacy: up to 130lm/W±5
    • -40°C to +45°C /50°C /55°CAmbient operating temperature
    • Mounting: U-bracket
    • Wide optics for uniform illumination
    • 5 years warranty
    • Entry Size: M25Χ1.5 or NPT 3/4”-14
    • Housing –Aluminum alloy (ADC12 )
    • Lens – tempered glass (10mm)
    • Beam angle: 120°

    Parameters

    •  Power: 100W / 120W / 150W/ 180W / 200W
    •  Input voltage: AC100-240/277V, 50/60Hz
    •  Power factor: 0.97
    •  Lumen flux: 13000LM / 15600LM / 19500LM / 23400LM / 26000LM
    •  CCT: 2700K - 6500K (Optional)
    •  LEDs: 3030
    •  LED Driver: Meanwell HLG series
    •  Dimension: Φ460 x 243(287)mm
    •  Weight: 14.3KG

    Certificate & Standard

    Have certified CES-EX-GB fixtures with the IECEX and ATEX standards for hazardous location and environments.

    ATEX:
    • II 2G Ex db op is IIC T4…T5…T6 Gb
    • II 2D Ex tb op is IIIC T103°C…T98°C …T93°C Db
    • Certify No:SEV 19 ATEX 0334 X
    IECEx:
    • Ex db op is IIC T4…T5…T6 Gb
    • Ex tb op is IIIC T103°C…T98°C …T93°C Db
    • Certify No:IECEx SEV 19.0040X

Send Your Iquiry

Make sure you enter all the required information, indicated by an asterisk (*). HTML code is not allowed.