For Zone 1 Zone 2, Zone 21 Zone 22 hazardous area led lighting, 20W - 200W, 130lm/W,aluminum alloy + 8mm tempered glass, multi-installation for different projects, such as light tower, canopy light, marine grade.
Flameproof enclosure, Ex db op is IIC T6 Gb, Zone 1 & Zone 21 with explosive gas atmosphere, Zone 21 and Zone22 with explosive dust atmosphere, 10mm temered glass, 7J impact resistance,up to 26000lm.
Flameproof enclosure, Ex db op is IIC T6 Gb, IP68 protection grade, tempered glass 10mm, withstand impacts up to 10J, 2 foot and 4 foot Length, 50Watt- 240Watt, 130lm/W light efficacy.
Zone 1 & Zone 21, 1ft, 2ft, 3ft, 4ft length can be selected, replace the traditional explosion-proof three-proof lamp, explosion-proof fluorescent tube, anti-corrosion, anti-glare, anti-drop, competitive price.
Flameproof LED hand lamp for Zone 1 & Zone 21 hazardous areas, 10mm tempered glass, pass the multi-angle drop test, 10W, 20W, 30W Power, can be connected to the cable, emergency power box.
The CES-EX-SF series explosion-proof ceiling lamp has a strong shell, with features such as impact resistance, vibration resistance, and corrosion resistance. It can be used in hazardous environments of Zone 1&21, Zone 2&22.
CES-EX-JX Series is your go-to solution for illuminating hazardous Zone 1 and Zone 21 areas. With ATEX approval, these Explosion-proof LED Flood Lights offer unbeatable safety standards.
Discover the pinnacle of safety and illumination with our CES-EX-GBX Series Explosion-proof LED High Bay Lights. Designed for hazardous Zone 1 and Zone 21 areas, these lights boast ATEX approval, ensuring the highest safety standards.
GB-02 explosion-proof lights are made of alloy aluminum and tempered glass, with shock resistance and anti-vibration performance. The luminaires have passed the ATEX IECEx standards test, from 30W to 80W for hazardous area lighting.
LN-02 explosion-proof lights obtained an IECEx ATEX certificate, it's safe for the Zone 1 and Zone 2 hazardous locations. The copper-free aluminum alloy body is powder-coated to increase durability and beautiful appearance, are able to withstand violent shaking and shock resistance.
an innovative line of LED hazardous area lighting products, specifically designed for use in potentially explosive atmospheres (Zone 1/21 & 2/22) within harsh industrial settings such as coal mines and oil & gas facilities.
Explosion-proof safety exit lamps are for personnel evacuation, and fire operations to provide lighting fire emergency lamps! It usually uses an external power supply, when the power automatically switches to the battery power state!
The use of LED lamps in marine environments has increased significantly in recent years. This is due to the many advantages offered by LED technology over traditional lighting technologies, including energy efficiency, durability, and environmental friendliness. However, there are some specific challenges that must be considered when designing and using LED lamps in marine environments. In this article, we will analyze the various aspects of LED lamps used in marine environments in detail.
Marine environments are harsh environments with various factors that can affect the performance of LED lamps. Some of the environmental factors that can affect LED lamps in marine environments are:
Salinity: Salinity is a critical factor that can affect the performance of LED lamps in marine environments. High salt content in seawater can corrode LED lamps, leading to premature failure.
Moisture: Moisture can also affect the performance of LED lamps in marine environments. The high humidity levels in marine environments can cause condensation inside the LED lamps, which can lead to short circuits and corrosion.
Temperature: Temperature fluctuations in marine environments can also affect the performance of LED lamps. Extreme temperature changes can cause thermal stress on LED lamps, leading to failure.
UV Radiation: UV radiation is another environmental factor that can affect LED lamps in marine environments. Prolonged exposure to UV radiation can cause the yellowing of LED lamps' lenses, leading to a decrease in light output.
To ensure the reliable performance of LED lamps in marine environments, it is essential to consider the following design considerations:
Enclosure: LED lamps used in marine environments must be enclosed in a durable, waterproof, and corrosion-resistant housing. The housing should be designed to protect the internal components of the LED lamp from exposure to saltwater, moisture, and other environmental factors.
Heat Dissipation: LED lamps generate heat during operation, and it is essential to dissipate this heat to ensure their reliable performance. In marine environments, it is essential to consider the cooling system's design to prevent corrosion and damage to the LED lamps' internal components.
Optics: Optics is an essential design consideration for LED lamps used in marine environments. The optics must be designed to ensure that the LED lamps' light output is directed precisely where it is needed, minimizing light pollution and maximizing efficiency.
Power Supply: LED lamps require a power supply to operate, and the power supply's design is critical to their reliable performance. In marine environments, it is essential to consider the power supply's waterproofing, corrosion resistance, and protection from voltage fluctuations.
LED lamps find numerous applications in marine environments, including:
Navigation Lights: Navigation lights are essential in marine environments to ensure the safe navigation of vessels. LED lamps are ideal for navigation lights due to their high efficiency, reliability, and long life.
Underwater Lighting: LED lamps are increasingly being used for underwater lighting in marine environments. Underwater LED lamps offer several advantages, including low power consumption, durability, and high color rendering index.
Deck Lighting: LED lamps are also commonly used for deck lighting in marine environments. LED deck lights offer several advantages over traditional deck lights, including energy efficiency, long life, and low maintenance.
Flood Lighting: LED floodlights find numerous applications in marine environments, including lighting up docks, harbors, and marinas. LED floodlights offer high efficiency, low power consumption, and long life, making them ideal for these applications.
In conclusion, LED lamps are increasingly being used in marine environments due to their many advantages over traditional lighting technologies. However, it is essential to consider the various environmental factors that can affect LED lamps'
We are pleased to tell that our 4 series (CES-J Series Explosion Proof LED Flood Light, CES-EX-LN-02P Series Explosion Proof Linear Light (Cost Efficiency), CES-EX-LN-02 Series Explosion Proof LED Linear (High Power), CES-EX-GB-02 Series Explosion Proof LED High Bay) of LED lights have obtained UL1598A certification for use in marine environments. This certification is a testament to our commitment to providing high-quality LED lighting solutions that are not only energy-efficient and durable but also safe and reliable in marine environments.
Our LED lights are specifically designed to withstand the harsh conditions of marine environments, including saltwater corrosion, high humidity, and extreme temperature fluctuations. With UL1598A certification, you can trust that our LED lights have undergone rigorous testing to ensure their performance and safety in marine environments.
Our LED lights are suitable for a wide range of marine applications. With our UL1598A certified LED lights, you can enjoy the benefits of high-quality LED lighting solutions that offer low power consumption, long life, and minimal maintenance requirements.
At our company, we remain committed to providing innovative and reliable LED lighting solutions for our customers in marine environments. With our UL1598A certified LED lights, you can trust that you are getting the best in class lighting solutions that meet the highest safety standards.
Thank you for choosing our LED lights for your marine applications. If you have any questions or require further information, please do not hesitate to contact us.
GB/T3836-2021 refer to China Explosion-Proof standards
IEC60079 refer to International Explosion-Proof standards
With the release and implementation of the new GB/T3836-2021 standard, China's explosion-proof standards are further in line with international explosion-proof standards. The new version of the national explosion-proof standard in the original GB12476, GB25286 standards on the basis of covering the explosive environment equipment design, manufacturing, inspection, selection, installation, inspection, maintenance, repair and site classification and other aspects, using the form of partial standards, including but not limited to the following parts.
GB/T 3836.1-2021 Explosive atmospheres - Part 1: General requirements for equipment
Corresponding IEC 60079-0:2017 Explosive atmospheres - Part 0: General requirements for equipment
GB/T 3836.2-2021 Explosive atmospheres - Part 2: Equipment protected by flameproof enclosure "d"
Corresponding IEC standard: IEC 60079-1:2014 Explosive atmospheres - Part 1: Equipment protected by flameproof enclosure "d"
GB/T 3836.3-2021 Explosive atmospheres Part 3: Equipment protected by increased safety type "e"
Corresponding IEC standard: IEC 60079-7:2015 Explosive atmospheres Part 7: Equipment protected by increased safety type "e"
GB/T 3836.4-2021 Explosive atmospheres - Part 4: Equipment protected by intrinsic safety type "i"
Corresponding IEC standard: IEC 60079-11:2011 Explosive atmospheres Part 11: Equipment protected by intrinsic safety type "i"
GB/T 3836.5-2021 Explosive atmospheres - Part 5: Equipment protected by positive pressure enclosure "p"
Corresponding IEC standard: IEC 60079-2:2014 Explosive atmospheres Part 2: Equipment protected by positive pressure enclosure "p"
GB/T 3836.6-2017 Explosive atmospheres Part 6: Equipment protected by oil immersion type "o"
Corresponding IEC standard: IEC 60079-6:2015 Explosive atmospheres Part 6: Equipment protected by Oil immersion type "o"
GB/T 3836.7-2017 Explosive atmospheres Part 7: Equipment protected by Powder Filling type "q"
Corresponding IEC standard: IEC 60079-5:2015 Explosive atmospheres Part 5: Equipment protected by power filling type "q"
GB/T 3836.8-2021 Explosive atmospheres Part 8: Equipment protected by type "n"
Corresponding IEC standard: IEC 60079-15:2017 Explosive atmospheres Part 15: Equipment protected by type "n"
GB/T 3836.9-2021 Explosive atmospheres Part 9: Equipment protected by Encapsulation type "m"
Corresponding IEC standard: IEC 60079-18:2014 Explosive atmospheres Part 18: Equipment protected by Encapsulation type "m"
GB/T 3836.11-2017 Explosive atmospheres - Part 11: Classification of properties of gases and vapors - Test methods and data
Corresponding IEC standard: IEC 60079-20-1: 2010 Explosive atmospheres Part 20-1: Classification of properties of gases and vapors Test methods and data
GB/T 3836.12-2019 Explosive Atmospheres Part 12: Combustible Dust Substance Properties Test Method
Corresponding IEC Standard: ISO/IEC 80079-20-2:2016 Explosive Atmospheres Part 20-2: Material Properties - Test Method for Combustible Dust
GB/T 3836.13-2021 Explosive atmospheres - Part 13: Repair, overhaul, restoration and modification of equipment
Corresponding IEC standard: IEC 60079-19:2019 Explosive atmospheres Part 19: Repair, overhaul and restoration of equipment
GB 3836.14-2014 Explosive Atmospheres Part 14: Classification of Locations Explosive Gas Atmospheres
Corresponding IEC Standard: IEC 60079-10-1:2008 Explosive Atmospheres Part 10-1: Classification of Hazardous Locations Explosive Gas Atmospheres
GB/T 3836.15-2017 Explosive atmospheres Part 15: Design, selection and installation of electrical installations
Corresponding IEC standard: IEC 60079-14:2007 Explosive atmospheres Part 14: Design, selection and installation of electrical installations
GB/T 3836.16-2017 Explosive atmospheres Part 16: Inspection and maintenance of electrical installations
Corresponding IEC standard: IEC 60079-17:2007 Explosive atmospheres Part 16: Inspection and maintenance of electrical installations
GB/T 3836.17-2019 Explosive atmospheres - Part 17: Equipment protected by positive pressure room "p" and artificial ventilation room "v"
Corresponding IEC standard: IEC 60079-13:2017 Explosive atmospheres Part 13: Equipment protected by positive pressure room "p" and artificial ventilation room "v"
GB/T 3836.18-2017 Explosive atmospheres Part 18: Intrinsically safe electrical systems
Corresponding IEC standard: IEC 60079-25:2010 Explosive atmospheres Part 25: Intrinsically safe electrical systems
GB 3836.20-2010 Explosive Atmospheres Part 20: Equipment with Equipment Protection Level (EPL) Ga
Corresponding IEC standard: IEC 60079-26:2006 Explosive atmospheres Part 26: Equipment with Equipment Protection Level (EPL) Ga
GB/T 3836.21-2017 Explosive atmospheres Part 21: Application of quality system for equipment production
Corresponding IEC standard: ISO/IEC 80079-34:2011 Explosive atmospheres Part 34: Application of equipment production quality system
GB/T 3836.22-2017 Explosive atmospheres Part 22: Protection measures for optical radiation equipment and transmission systems
Corresponding IEC standard: IEC 60079-28:2006 Explosive atmospheres Part 28: Protection measures for optical radiation equipment and transmission systems
GB/T 3836.23-2017 Explosive atmospheres Part 23: Class I EPL Ma equipment for gas and/or coal dust atmospheres
Corresponding IEC standard: none
GB/T 3836.24-2017 Explosive atmospheres Part 24: Equipment protected by special type "s"
Corresponding IEC standard: IEC 60079-33:2012 Explosive atmospheres Part 33: Equipment protected by special type "s"
GB/T 3836.25-2019 Explosive atmospheres Part 25: Requirements for process sealing between flammable process fluids and electrical systems
Corresponding IEC standard: IEC TS 60079-40: 2015 Explosive atmospheres Part 40: Process sealing requirements between flammable process fluids and electrical systems
GB/T 3836.26-2019 Explosive Atmospheres Part 26: Guidance on Electrostatic Hazards
Corresponding IEC standard: IEC TS 60079-32-1:2013 Explosive atmospheres Part 32-1: Guidance on electrostatic hazards
GB/T 3836.27-2019 Explosive atmospheres Part 27: Electrostatic hazard test
Corresponding IEC standard: IEC 60079-32-2:2015 Explosive atmospheres Part 32-2: Electrostatic hazard test
GB/T 3836.28-2021 Explosive atmospheres - Part 28: Non-electrical equipment for explosive atmospheres - Basic methods and requirements
Corresponding IEC standard: ISO 80079-36:2016 Explosive atmospheres Part 36: Basic methods and requirements for non-electrical equipment for explosive atmospheres
GB/T 3836.29-2021 Explosive atmospheres - Part 29: Non-electrical equipment for explosive atmospheres - Structural safety type "c", controlled ignition source type "b", liquid immersion type "k"
Corresponding IEC standard: ISO 80079-37:2016 Explosive atmospheres Part 37: Non-electrical equipment for explosive atmospheres Non-electrical explosion-proof type structural safety type "c", control ignition source type "b", liquid immersion type "k"
GB/T 3836.30-2021 Explosive atmospheres - Part 30: Equipment and components for explosive atmospheres in underground mines
Corresponding IEC standard: ISO/IEC 80079-38:2016 Explosive atmospheres Part 38: Equipment and components for explosive atmospheres in underground mines
GB/T 3836.31-2021 Explosive atmospheres - Part 31: Equipment protected by dust ignition-proof enclosure "t"
Corresponding IEC standard: IEC 60079-31:2013 Explosive atmospheres Part 31: Equipment protected by a dust ignition-proof enclosure "t"
GB/T 3836.32-2021 Explosive atmospheres - Part 32: Electronically controlled spark time limit intrinsically safe systems
Corresponding IEC standard: IEC TS 60079-39: 2015 Explosive atmospheres Part 39: Electronically controlled spark time limit intrinsically safe systems
GB/T 3836.33-2021 Explosive atmospheres Part 33: Equipment for severe working conditions
Corresponding IEC standard: IEC TS 60079-43:2017 Explosive atmospheres Part 43: Equipment for severe working conditions
GB/T 3836.34-2021 Explosive atmospheres - Part 34: Complete sets of equipment
Corresponding IEC standard: IEC TS 60079-46:2017 Explosive atmospheres Part 46: Complete equipment
GB/T 3836.35-2021 Explosive Atmospheres Part 35: Classification of Explosive Dust Atmospheres
Corresponding IEC standard: IEC 60079-10-2: 2015 Explosive atmospheres Part 10-2: Location classification Explosive dust atmospheres
In the maintenance of oil tank area, we need to pay attention to some matters to ensure the safety of maintenance personnel and the smooth maintenance work.
CESP SC-series explosion proof led hand lamp is suitable for the inspection working in the hazardous location. ATEX IECEX Zone 1 Zone 21 and UL844-Class 1 Division 1 approved.
The top 10 explosion-proof lighting manufacturers in China are recommended here.
Note: The name listing is given for person evaluation and is for reference only.
WAROM
Listed company, strong strength, is China's oldest explosion-proof equipment, explosion proof lights manufacturer, complete product line.
Mainly engaged in explosion-proof electrical equipment, professional lighting research and development, production and sales. On May 24, 2017, the company was successfully listed on the A-share market of Shanghai Stock Exchange (stock abbreviation: Huarong Stock, stock code: 603855).
The company's management is fully in line with the international advanced level, taking the lead in passing the certification of IS09001 quality management system, ISO14001 environmental management system, ISO10012 measurement management system and OHSAS18001 occupational health and safety management system. At the same time, the United States FM/UL, ATEX, IECEx, Russia CU TR, Brazil INMETRO certification and other international quality standard certification.
As the oldest explosion-proof brand in China, Warom entered the international market very early, with subsidiaries in different countries and enjoys popularity.
KING OCEAN
Ocean King was established in August 1995. It is a company that independently develops, produces and sells various professional lighting equipment, lighting (including explosion-proof lamps) + intelligent control systems, service products, and undertakes various lighting engineering projects. Private joint-stock high-tech enterprise, listed on the small and medium-sized board of Shenzhen Stock Exchange on November 4, 2014, the company has more than 3,000 employees, serving electric power, metallurgy, railway, oil field, petrochemical, public security, fire protection, coal, military, venues, ships, etc. Large and medium-sized state-owned enterprises and institutions. Ocean King is committed to providing customers with humanized professional lighting solutions, and strives to become the best service company for professional lighting in the world.
Explosion-proof lamps manufacturer, mainly active in China, mainly in traditional (non-LED) explosion-proof lamps. Traditional lamps are ATEX and IECEX certified.
NJZ
Founded in 2012, NJZ Lighting is a technology-leading manufacturer, driving the most innovation and durable portfolio of industrial lighting products for Hazardous location, General industry and Marine applications.
a full line of globally certified explosion proof lighting fixtures to deliver a professional and durable lighting solutions for the application where there is potential risk such as combustible gas or dust. NJZ products and manufacturing system are both approved and certified by the UL and TUV organization according UL844 and IECEX 60079.
CESP
SHENZHEN CESP CO.,LTD, Founded in 2007, Committed to providing high-quality patented products in the military and industrial fields, CESP is top explosion-proof lamp OEM and ODM manufacturer and supplier from China, and the first UL and CUL certified hazardous location LED lighting company in China.
CESP explosion-proof lighting products are all patented products of proprietary mould, and have obtained UL844 North American explosion-proof certificate, ATEX explosion-proof certificate, IECEx explosion-proof certificate, and most products have also obtained UL1598A coastal defense anti-corrosion certificate.
In addition, in December 2020, CESP launched a Class 1 Division 1 explosion-proof hand lamp, which was issued by the CSA Group.
KHJ
Shenzhen KHJ Semiconductor Lighting Co., Ltd. was established in 2009, the company is a collection of research and development, production, sales in one of the enterprises.
Products include explosion-proof lighting, explosion-proof electrical appliances, industrial lighting, commercial lighting four major divisions, respectively committed to the security field, industrial field, commercial field and special light source field of the lamp product research and development, production and sales. Since its establishment in 2009, the product variety has gradually developed from a single light source into four major divisions. The scope of the market has also expanded from a single commercial field to industrial and security fields.
SNC
Founded in 2012, SN has been committed to the research and development, production and sales of LED lighting products. It is a powerful high-tech manufacturer. It has successively passed a series of quality, environmental management system and enterprise intellectual property management system certifications such as ISO9001:2015 and ISO14001:2015.
In recent years, SNC has developed explosion-proof floodlights, explosion-proof high Bay, explosion-proof line lights, and obtained the North America explosion-proof certificate, rapidly occupying the North American market.
In addition, SNC is also developing other special lighting products, such as livestock lighting, poultrylighting, grow lighting, intelligent lighting, etc.
PAN MEI (James, Venas)
Dongguan Pan Mei electronics Co., Ltd. is a professional, comprehensive and global manufacturer of LED lighting, explosion-proof lighting and explosion-proof electrical appliances.
Product roadmap are LED commercial lighting, led industrial lighting, UV lamp, plant lamp, industrial explosion-proof lamp, industrial explosion-proof electrical appliances and other fields.
Pan Mei focuses on providing industrial lighting and commercial lighting. After long-term efforts, PanMei electronics has obtained UL, CQC, IECEx, ul844, ATEX, ABS, EAC, NOM certification for different types of industrial lighting products.
Pan Mei is become a lighting brand in North America and Europe and have a local customer service team in North America and Europe to provide 24-hour delivery service.
OUHUI
Jiangsu Ouhui Lighting Co., Ltd. is a high-tech enterprise engaged in explosion-proof lamps, electrical appliances, professional lighting products, emergency lighting lamps research and development, production and manufacturing, sales and service in one, with a professional R & D team, advanced testing and production equipment, excellent and reliable sales and after-sales service personnel. The company has strong technical force, in the optical, electronic, electrical and other professional fields, with process engineers, structural engineers, quality engineers, R & D engineers and other high, intermediate technical personnel.
Ouhui has risen rapidly in recent years, mainly with ATEX type explosion-proof lamps.
CARY
Shenzhen CARY is located in the forefront of LED technology in China - Shenzhen. Is a 15 years engaged in industrial and outdoor lighting research and development, integrated lighting design, marketing, service high-tech enterprises.
The products are widely used in power generation, substation, high-speed railway construction, oil exploitation, refining, mining, shipyard, automobile factory and other fields.
CARY's products have passed CE, ROHS, ATEX, UL844, ETL, DLC and other certifications. With experienced R & D team, exquisite technology, scientific management system, excellent quality and efficient service, Cary has market share in China, North America, Europe, Russia, the Middle East and North Africa.
TORMIN
Zhejiang Tormin is a national high-tech enterprise specializing in the research and development, production and sales of industrial lighting fixtures. Products are widely used in petroleum, chemical, electric power, mining, metallurgy and other industrial enterprises lighting, China's national high-tech enterprises ", "National Torch program", the company has passed the ISO9001 quality, ISO14001 environment, OHSAS18001 occupational health and safety management system certification, The products have passed the national coal mine safety certification, the National Lamps and Lanterns Quality Supervision and Inspection Center and the National explosion-proof electrical Products Quality Supervision and inspection Center and other domestic authority certification, in China, Tongming explosion-proof lamps and explosion-proof electrical appliances are used in many projects.
For the international market, Tormin explosion-proof lamp is mainly European ATEX explosion-proof certification, IECEx international explosion-proof certification.
Explosion-proof sealing connector are also called explosion-proof cable glands, which are used for tightening and sealing of cables of explosion-proof equipment.
Thread specifications are divided into the following four types:
Metric M thread, German PG thread, American NPT taper thread, Imperial G(PF) pipe thread
The most common demand is M thread. Among the specifications, M12, M20, M25, M32, M63, M72, M75, etc., the common pitch is 1.5 and 2.
There are also some threads that are not conventional and need to be customized, such as reducing-diameter explosion-proof cable glands. The specifications at both ends are customized according to the interface specifications of the introduction device of the explosion-proof equipment on site.
For unconfirmed specifications and sizes that need to be purchased, you should confirm with the seller, because generally non-standard customized specifications of explosion-proof cable glands cannot be returned after sale, so if the purchase quantity is large, it is best to order samples to confirm that they are correct, and then place bulk orders.
The product is generally made of S304 stainless steel, with unique explosion-proof function, special design of clamping melon and clamping ring, large clamping cable range, strong tensile strength, waterproof, dustproof, salt resistance, weak acid resistance, Alcohol, oil, fat and general solvents.
The following is the size comparison table of inch thread (G), metric thread (M), American thread (NPT) and German thread (PG)
CESP provides customized explosion proof cable glands of 316 stainless steel, high temperature resistant, flame retardant, etc. Protection level: within the specified bayonet range, and use the sealing ring to tighten the tightening head to reach IP68-5 Bar.
Welcome to contact us!
Restricted breathing lamps are a kind of "n" type explosion-proof products. They are used in enviroment with potentially explosive gas atmospheres in Zone 2. They are the same as increased safety lamps in terms of use, but their light source types are higher than that of increased safety lamps. The weight is lighter than that of flameproof lamps, but the scope of use is not as wide as that of flameproof lamps. It has the characteristics of light weight and various types of applicable light sources. It is undoubtedly an economical and easy-to-use product for use in places where good lighting is required in zone 2.
According to IEC/EN 60079-15 Type of Protection “ n ”
Electrical installations designed so that ignition is unlikely to occur in normal or abnormal operation. The gas explodes. The main protection methods are classified as follows.
This new type of product has many novelties in explosion-proof mechanism, characteristics, inspection difficulties and design. Only when designers and users understand these can they be well designed and used.
To understand the explosion-proof mechanism of the restrictive breathing lamp, we must first understand where it is used, and understand where to start with this product to consider the explosion-proof structure treatment.
Restricted breathing lamps have certain restrictions on the use of this kind of lamp, which is only allowed to be used in places with potential explosion hazard gas environment 2, that is to say, the place where this lamp is used is relatively less dangerous. In normal operation, there are no explosive hazardous substances in the environment, including gases, vapors and mist, and dangerous explosive gases, vapors or mist will appear only when they fail, and the chance of such failure is very small, and even if there is a failure, the time of failure is very short. It is precisely because of the particularity of the use environment that this kind of lamp only needs to prevent the danger of dangerous substances in rare cases and the duration of dangerous substances is extremely short. Therefore, the shell of this kind of lamp is to limit the amount of gas, vapor and mist entering, rather than preventing gas, vapor and mist from entering.
When the lamp is working normally, the calorific value of the internal light source is relatively high, which will cause the internal gas to expand and form a positive pressure in the light source cavity of the lamp. Due to the formation of positive pressure, the internal gas leaks out. When the lamp is out of use, the inside of the lamp will gradually cool down. At this time, due to the temperature drop in the lamp, the gas volume is reduced. At this time, the air volume in the lamp is smaller than that in the initial state of the lamp, which causes the inside of the lamp. of negative pressure. If the lamp does not take protective measures, and an accident happens at this time, there is a leakage of dangerous substances, then the dangerous substances may enter the lamp. When the lamp is used again, the high temperature inside the lamp may ignite the explosive gas, vapor or mist existing in the lamp, resulting in a dangerous accident. Restricted breathing lamps are based on this characteristic of lamps, and the light source and its related electrical components are put into restricted breathing enclosures. A restricted breathing enclosure is a type of enclosure that restricts the entry of gases, vapors and mists. That is to say, a restricted-breathing luminaire is a luminaire product with a special housing. This product increases the ability of the housing to restrict the ingress of gases, vapors and mists, so hazardous substances do not enter the luminaire for a short period of time. Of course, if the accident lasts for a long time, there will be danger. Therefore, for this kind of lamps, corresponding measures have been taken to further increase the safety. First of all, its use place is limited, and it is only allowed to be used in Zone 2, so that due to the short maintenance time of the accident, the number of accidents is less, and the chance of danger is reduced. At the same time, strict performance inspections have been carried out for the dangerous components in the casing, such as ballasts, lamp sockets, starters, etc., to ensure the safety and reliability of the components. In this way, this explosion-proof lamp is safe.
Before the emergence of restricted breathing lamps, there were two commonly used lamps in the explosion-proof lamps family: explosion-proof lamps and increased safety lamps. Explosion-proof lamps can be used in areas with potentially explosive gas atmospheres in Zone 1. This kind of lamp mainly uses the high strength and explosion-proof property of the product shell to achieve the purpose of explosion-proof, allowing accidents in the surrounding environment and dangerous substances in the lamp. It uses the strength of the lamp shell to prevent the pressure generated by the internal explosion of the lamp from damaging the lamp body and ignites the surrounding environment, and at the same time uses the extremely small gap between the metal joints of the shell to prevent the flame in the lamp from igniting the surrounding flammable substances; Lamps are also a kind of explosion-proof lamps that are widely used. This kind of lamps is designed by adding a series of safety measures, such as increasing the electrical clearance and creepage distance, increasing the protection level of the shell, and using explosion-proof lamps where sparks may occur in the lamps. Measures to deal with, limit the temperature level of lamps, etc. to achieve safety purposes. In my country, most of this type of explosion-proof lamps are used in Zone 2, and only increased safety single-plug fluorescent lamps are allowed to be used in Zone 1.
Through the above description, it is not difficult to find that the restricted-breathing lamps achieve the purpose of explosion-proof by restricting the entry of explosive gas, vapor or mist into the interior of the lamp body through the good sealing of the shell; And high-strength shell to achieve the purpose of explosion-proof; increased safety lamps and lanterns by increasing the safety of the lamp itself to achieve the purpose of explosion-proof lamps. Therefore, these three lamps each have different characteristics.
Through the description of the explosion-proof principle of restricted-breathing lamps, it is not difficult to find that restricted-breathing lamps mainly improve the reliability of internal components, at the same time increase the protection capability of the shell, and limit their use places. This also determines its different characteristics from other explosion-proof lamps.
First of all, due to the requirements for limiting the protection capability of the internal components and shells of the breathing lamps, the restricted breathing lamps have higher requirements on the selection of internal components: they must be components with reliable performance and firm connections. After the components are selected, the main hazards of this kind of lamps are the limited breathing ability of the shell and the heating problem of the product surface. Therefore, the measurement of the surface temperature in the inspection is to select the surface of the lamp body, which is the same as the explosion-proof product, which also forms a great advantage compared with the increased safety lamps.
The increased safety lamp is to increase the safety of all parts of the lamp, including the temperature limit. Therefore, the temperature measurement of the increased safety lamp is to detect the high surface temperature of each component inside the lamp, so that when the increased safety lamp determines its temperature group The temperature is determined by measuring the high temperature points on the surface of the light source. Therefore, the heat generation of the increased-safety lamps is very high, and their applicable range is narrow. Those flammable gas environments with low ignition temperature are not suitable for the use of increased-safety lamps. It is precisely because the safety-enhancing lamps and lanterns are considering the safety of the internal components of the lamps and lanterns, which have certain restrictions on the use of light sources. In the national standard currently used in my country, only cold-start fluorescent lamps, incandescent lamps and self-ballasted fluorescent lamps are allowed. Light bulbs that ignite for a short time after being broken (verified that the short-term high temperature of the bulb does not cause danger). From the restrictions on the increased safety lamps, it is not difficult to find that the restricted breathing lamps and lanterns use the restricted breathing type casing, so when measuring the surface temperature of the lamp, the temperature of the outer surface of the lamp is measured. In this way, under the condition of good lighting design and good heat dissipation, it is easy to reduce the surface temperature of the lighting and broaden the use range of the lighting. While reducing the surface temperature of the lamps, the types of light sources used by the lamps are also increased. Since the housing is of a restricted breathing type, the interior of the luminaire is relatively safe, so most of the light sources can be used except for those light sources that are dangerous to the luminaire itself. Restricted breathing lamps can use incandescent, mercury, sodium and metal halide lamps as well as fluorescent lamps. In this way, the illuminance of the restricted breathing lamps is greatly increased. Some lamps that need high illumination and high heat generation hanging at the height of the workshop can completely use the restricted breathing lamps, because it is easy to form a zone 2 dangerous place at the height of the workshop.
Secondly, since the restricted breathing type luminaire only needs to have the restricted breathing capacity of the outer casing, it does not need to make the outer casing as thick as the flameproof type lamp, making the lamp very heavy. In this way, in some places that require high illuminance and low degree of danger, restricted breathing lamps can completely replace explosion-proof lamps, because they are lighter than explosion-proof lamps, but they can use the same light source and have the same temperature group. do not. Of course, it cannot be used in Zone 1 hazardous locations, and the scope of use is small, which is incomparable with explosion-proof lamps.
To sum up, the restricted breathing lamp has the characteristics of low external heat generation, wide applicable temperature range, relatively many types of light sources, and relatively light shell.
From the explosion-proof principle and characteristics of restricted breathing lamps, it is not difficult to find the main problems in their inspection.
First of all, the restricted-breathing lamps have high requirements on the performance of the internal components, so the inspection of the internal components of the lamps in the inspection is quite cumbersome. Mainly focus on the inspection of ballasts, lamp sockets and starters. It is mainly the inspection of the ballast and the starter, including the high-voltage pulse test of the ballast and the performance inspection of the starter seat, which not only costs high test costs, but also takes a long time to test.
Secondly, it is a difficult point in the inspection that the enclosure of the restricted breathing luminaire restricts the breathing ability. For longer joints in luminaires, it is difficult to pass the test of the restricted breathing enclosure. Because during the test, it is required to evacuate the shell to -3
kPa, and then rely on the sealing performance of the shell itself so that it does not drop to 1.5kPa within 3min. This test has very strict requirements on sealing and requires very good elasticity of the gasket. In the large number of experiments we have conducted, not a single unit has passed the test at one time, and all of them are continuously improved in the experiment, so as to finalize the final product design.
Through the above analysis, several suggestions are put forward for the design of restricted breathing lamps.
First, because of the reduction in the joint surface that restricts the breathing shell. The more surfaces a restricted breathing enclosure has, the more leak points it will have. Conversely, the fewer surfaces a restricted breathing enclosure has, the fewer leak points it will have, so that the chance of passing the restricted breathing enclosure test is better. bigger. Even if there is a leak, it is easy to identify the leak and remedy it.
Second, reduce the length of the joint surface. Due to the high degree of sealing required by the restricted breathing type housing, the longer the distance of a joint surface, the more leakage points. To seal, the sealing distance must be reduced, so that the number of fasteners will increase, which will be difficult to install and disassemble. Add trouble.
Finally, avoid the difficulty in testing. During the inspection, the inspection of some internal components is quite time-consuming; it will also cost a lot of inspection funds, and we can also try to avoid it in the design.
We all know that paint is a flammable chemical. When the paint reaches a certain concentration in the air, it will burn and explode when it encounters a high temperature open flame. The spray booth is a place where paint does not exist all the time.
The fire hazard of the spray booth is related to the type of paint used, the spray booth method and usage, and the conditions of the spray booth. When flammable paints and organic solvents are used, the danger of explosion and fire is high. Explosion and fire accidents will cause serious loss of life and property, and seriously affect the normal production.
Explosion-proof lamps refer to fixture that take various specific measures to prevent the ignition of surrounding explosive mixtures such as explosive gas environments, explosive dust environments, and gas gases. That is to say, the led explosion-proof lamp is in contact with the explosive gas, there is no possibility of combustion and explosion, and it can play an explosion-proof effect.
Appropriate illuminance is a very important indicator for the spray booth. Its importance is reflected in: for some workpieces with relatively flat painted surfaces and relatively simple structures, it is acceptable to have a slight lack of illuminance, but for some workpieces with complex structures, if the illuminance of the light source is insufficient, it will be very difficult. It may cause a series of painting problems such as excessively thick, too thin, missing, and flowing paint in some local areas.
Matters needing attention for light source lighting in the spray booth:
First, let’s take a look at the requirements of the spray booth for natural light sources. The light source does not only refer to artificial light sources. If there are natural light sources, natural light sources should be the main ones, but sunlight cannot be directly irradiated on the paint surface. The effect has a greater impact. We can use the baffle to avoid direct sunlight and make the light softer, but it cannot affect the overall lighting, and pay attention to the direction of the light, so that it cannot be easily irradiated to the eyes of the sprayer. Sometimes it is difficult to ensure sufficient light source for natural light. Generally speaking, the area of the window used for lighting should not be less than 20% of the illuminated area.
Second, even if the lighting window is of the right size, it is difficult to ensure sufficient illuminance, because natural light sources are not stable, and in this case, the provision of artificial light sources is essential. When configuring artificial light sources, we must first consider saving, not only to ensure sufficient illuminance, but not to pursue too high illuminance. In order to save the energy consumption of artificial light sources, it is also necessary to control the reflectance inside the spray booth. Generally speaking The reflectivity of the ceiling is generally required to reach more than 85%, and the reflectivity of the wall is generally required to be 60%-70%. Therefore, the ceiling and walls of the spray booth we see are generally white and smooth, and the ground generally requires a reflectivity of 20%. %-30%, this is because the ground has less influence on the illuminance than the ceiling and walls. Generally, the ground of the spray booth is made of non-slip light-colored terrazzo. In addition, for other equipment used for painting, light-colored paint should be used as far as possible on the main color, which is also to maximize the reflectivity.
Third, the requirements for the lighting effect of artificial light sources. The artificial light source should be as uniform as possible, and the illuminance should not be less than 500 LUX. If necessary, local artificial lighting can be added separately.
Explosion-proof lights are widely used in painting room decoration lighting projects, including equipment painting, aluminum alloy doors and windows painting, furniture painting, automobile painting, etc., explosion-proof lights will be used. Therefore, it is very important to choose the right explosion-proof lamps and the right quantity for different spray booths.
What do we need to consider when selecting explosion-proof lamps? The following points are listed below for reference:
one old customer who has a furniture painting project. The room is roughly 5.8 meters length, 4.2 meters width and 2.8 meters height. The total area of each room is about 20 square meters. How many lights are needed in a room? This customer has purchased several LED explosion-proof lamps from our factory before, most of which are used to replace traditional explosion-proof metal halide lamps and explosion-proof fluorescent lights. Their factory mainly provides lighting fixtures for some oil refineries, boiler flue gas desulfurization projects, and waste-to-energy plants. For the lighting project of furniture painting, we recommended CES-EX-LN-02P series LED explosion-proof floodlights to him. This fixture meets the gas explosion-proof requirements of the painting room, and also meets its lighting brightness requirements.
In addition, a customer in the UK made a request for their car paint booth project:
No matter what kind of spray booth, we will provide a design that meets the lighting requirements according to the customer's application scenario.
If you have any needs, please feel free to contact us. We are happy to offer you a dialux design solution free of charge.
The explosion-proof lamps of flameproof type is mainly in the product structure, with a certain explosion-proof joint surface or explosion-proof thread, through an integral explosion-proof shell, to withstand the explosion pressure of the explosive mixture that may be generated inside the lamp, And prevent the explosion to the surrounding explosive mixture to achieve explosion-proof purposes.
Flameproof Type Explosion Proof LED Light CES-EX-LN Series
“10mm-thick tempered glass + ADC12and 6063 aluminum housing for CES-EX-LN explosion proof led linear light is shock-resistant, anti-vibration, can withstand 7J impact, and is equipped with micro-light elements to reduce direct visual contact with the light source, prevent glare, and replace the old and prone to failure Fluorescent light fixtures.”
Part. 1 The explosion-proof principle of flameproof lamps
Flameproof explosion-proof lamps, which can be used with a power supply not exceeding 1000V include incandescent lamps, tungsten halogen lamps, fluorescent lamp (including compact fluorescent lamps), high-pressure mercury lamps, high-pressure sodium lamps, self-ballasted high-pressure mercury lamps and metal halide lamps, etc. . Its structural characteristics are first of all that it must have a device that can withstand the requirements of IEC 60079-1 "protected by a flameproof enclosure "d". This integral flameproof enclosure, including the lamp body parts and Equipped with this, there are two parts of transparent parts such as a solid lampshade. According to the shape of the light source and the distribution of the illuminants, common flameproof lamps can be generally classified into vertical lamps equipped with gas discharge light sources such as incandescent lamps and high-pressure mercury lamps, and horizontal lamps equipped with straight fluorescent bulbs. There are two basic types of lamps. Its common components are lamp body, transparent parts, sealing parts, lamp sockets, inner reflectors and outer lamp umbrellas. The judgment of a good flameproof lamp mainly depends on the reasonable structure of the lamp body and the matching flameproof joint surface, the transparent part that can withstand the impact test and the thermal shock test, and the rubber seal with strong anti-aging ability. The lamp body is fixed with the transparent part, and then equipped with a lamp holder with reliable electrical performance. Through the reasonably designed inner reflector and outer lamp umbrella, the luminous flux of the light source inside the lamp can be irradiated to the outside of the lamp through the transparent part to the maximum extent, and the danger of explosion is caused. Ideal lighting effect for places. How to organically combine these components and make a reasonable layout is the key to the design and development of flameproof and explosion-proof lamps at present and in the future.
Part.2 Basic requirements for flameproof enclosures of lamps
For flameproof lamps, the flameproof enclosure is the key component of this type of flameproof explosion-proof electrical equipment, so the flameproof enclosure must meet the general requirements and special requirements for flameproof performance.
The national explosion-proof standard of flameproof enclosure requires that it can withstand the explosion pressure of the internal explosive gas mixture and prevent the internal explosion flame from spreading to the explosive mixture around the enclosure; to meet this performance, the following special requirements must be specifically considered:
Flameproof Proof LED Hand Lamp CES-EX-SC Series (ATEX / IECEx Zone 1)
“Durable, corrosion-resistant, and has undergone extreme hydraulic and heavy pressure tests and can withstand 7J impact. It has the characteristics of small size, light weight, portable etc. No hot when operate at the highest temperature, internal locking can prevent the cable from pulling out. can be used in hazardous areas Zone 1&21, Zone 2&22.”
Part.3 Design, manufacture and installation of transparent parts of flameproof lamps
As a flame-proof type explosion-proof lamp, there must be a certain light-transmitting part. At present, our country is basically made of glass material and is fixedly installed on the cavity of the explosion-proof lamp. Therefore, these glass transparent parts of flameproof lamps must not only meet the impact test and thermal shock test requirements of the transparent parts in the general requirements of IEC 60079-0, but more importantly, they must withstand the requirements specified in IEC 60079-1. Dynamic Strength Test. This requires that these transparent glass parts need to have sufficient strength, that is, they must have sufficient thickness and a certain geometric distribution, and undergo processing such as tempering. When designing transparent glass parts, we must pay attention to the reasonable selection of glass thickness and the determination of shape. Everything is premised on avoiding uneven stress in the finished product of the transparent parts, and at the same time, it is necessary to ensure that there is no sudden change in thickness. The main advantages of glass are that it can maintain its physical and light transmission properties under high temperature, ultraviolet radiation and long-term humid conditions, the surface is resistant to scratches by hard particles, and it is allowed to be immersed in aqueous or organic solvents without causing stress. cracks or corrosion. The main disadvantage of glass is its brittleness and low tensile strength. In order to make up for these shortcomings, when designing the assembly structure of the glass transparent part and the lamp body, a gasket is usually inserted between the glass transparent part and the metal parts of the lamp housing to prevent point contact with the metal parts of the housing and damage the glass transparent part. In order to prevent the impact of solid foreign objects from breaking the glass transparent parts, the commonly used method is to add a grille to protect it. If no grille grille is installed, the glass transparent parts must pass the high energy impact test specified in IEC 60079-0.
Generally, when the transparent parts of flameproof lamps adopt a sealed structure, the thickness of the gasket shall not be less than 2.0mm, and the width of the embedded part of the gasket between the metal shell and the glass transparent part shall not be less than 10.0mm. At the same time, glass transparent parts should generally be installed in the inner cavity, because when there is pressure inside, the elastic gasket tends to be compressed, which will strengthen the sealing performance. The material of the elastic gasket is generally made of nitrile rubber; when the power of the lamp is large, asbestos rubber sheet or silicone rubber, fluorine rubber and other materials that are self-extinguishing from fire can be used. It must also be noted that when installing the glass transparent parts, measures should be taken to ensure that the perimeter of the lampshade, glass tube and transparent plate should be compressed structurally, and the force should be uniform to avoid causing dangerous mechanical stress inside the transparent parts. For the glass transparent parts of explosion-proof lamps, it can also be sealed and fixed by direct glue sealing with the shell lamp body. This structure has higher requirements on the sealing material, and silicone rubber is suitable. The fixing of the transparent part of the luminaire and the housing part must be ensured in structure that when the light source is replaced, the transparent part and the sealing part shall not fall off the housing part.
Part.4 Selection of the introduction method of explosion-proof lamps
The introduction method of flameproof lamps is clearly stipulated in IEC 60079-1, that is, indirect introduction methods are required for lamps, but direct introduction methods can be adopted for Class I fluorescent lamps with flameproof lamp sockets and cold-start fluorescent lamps. This regulation of the introduction method is mainly due to the fact that it is impossible to completely avoid the generation of sparks, arcs or dangerous temperatures inside the explosion-proof lamps during normal operation. The indirect introduction method is to electrically connect the lamp with cables or wires through the junction box or plug, and the lamp is divided into two independent cavities in structure, the main cavity of the lamp and the wiring cavity, that is, the two-chamber explosion-proof cavity. Structure, so that the reliability of explosion-proof safety is fully guaranteed.
Part.5 Maintenance of explosion-proof lamps
Explosion-proof lamps are allowed to be repaired in principle, and the specific requirements are:
Detachable parts of lamps and lanterns are allowed to be replaced with accessories. The accessories must be the same as the original and must meet the relevant regulations of IEC 60079-1, IEC 60079-2 and IEC 60079-7 respectively.
The replacement here is to replace the maintenance activities with accessories. Generally, non-professionals are required not to open or disassemble the flameproof lamps. The usual maintenance is mainly to replace the consumable electrical components such as the light source and the starter of the fluorescent lamp and the trigger of the gas discharge lamp. , After the installation and disassembly of the lamp, pay attention to whether the gasket between the transparent part of the lamp and the lamp body is restored to the original compressed state. If the sealing gasket is damaged, it must be replaced in time to ensure the reliability of explosion-proof performance.
The lamp holder can be replaced as a whole. The explosion-proof lamp holder used for replacement must have a certificate or document approved by the explosion-proof inspection unit. The lamp holder accessories must be in good contact and have the heat resistance of the original.
The lamp holder is allowed to be replaced as a whole, mainly because the lamp holder is a complete part. The assembly of the lamp holder has many mutually restricting effects. If the parts are replaced, it will often affect the overall electrical performance of the lamp holder. The electrical conductivity and heat resistance of the socket accessories are very important. Random replacement will definitely reduce the overall performance of the lamp socket. Therefore, the requirements for the lamp socket accessories are relatively high, which is completely to avoid sparks inside the lamp. , The arc angle is considered.
The ballast of explosion-proof lamps can be replaced with accessories of the same model and capacity. When changing the ballast mode, it must be approved by the explosion-proof inspection unit.
The technical performance of different types of ballasts is not exactly the same. When replacing different types of ballasts, it may cause changes in the temperature rise, insulation performance, and working performance of explosion-proof lamps. In explosion-proof lamps, this change It will definitely affect the explosion-proof level, so it is stipulated that only accessories of the same model and capacity are allowed to be replaced. When changing the ballast method, the temperature rise of the entire ballast component will change more, so the temperature rise and other tests must be re-tested. Determine the new explosion-proof level, and this kind of test identification can only be recognized after passing the test of the explosion-proof inspection unit.
If
According to the Standardization Law of the People's Republic of China, all explosion-proof standards are mandatory standards and must be enforced. Explosion-proof products (including imports) used in China must be certified by the state-designated explosion-proof inspection agency. Explosion-proof inspection and certification agencies, in accordance with the Chinese national standard GB3836 series, review and test the explosion-proof performance of explosion-proof motors, explosion-proof electrics, explosion-proof lights, explosion-proof instruments, explosion-proof communication equipment, explosion-proof transportation vehicles and explosion-proof mechanical equipment, and issue explosion-proof certificates. In addition to the GB3836 standard, China's coal safety certification also adopts China's unique industry standards for mining products.
China's explosion-proof standards are basically formulated according to the IEC standards of the International Electrotechnical Commission.
The relevant parameters of the same version of the national standard and the European standard are basically the same, but due to the time lag, the relevant parameters of the national standard are different from the European standard. In the 2004 and 2007 editions of the IEC standard, IIA and IIB have implemented the same parameter requirements.
However, the requirements of China's explosion-proof standards are basically the same as those of IEC. Some of China's GB3836 standards (gas) and GB12476 standards (dust) directly adopt IECEx explosion-proof standards.
China Explosion Proof Certification Standards for Explosive Gas Atmospheres:
China's explosion-proof certification standards for combustible dust environments:
International IEC explosion-proof certification standards:
If you are looking for the IECEx or ATEX Certifed Zone 1 Zone 21, Zone 2 Zone 22 Explosion Proof LED Light, please contact us by email: This email address is being protected from spambots. You need JavaScript enabled to view it. / This email address is being protected from spambots. You need JavaScript enabled to view it.
Tab: explosion proof electrical equipment, anti-corrosive lighting, marine lighting, corrosion resistant Lighting, influence of corrosive environment
The manufacture of any electrical equipment is inseparable from the materials and the use of any electrical equipment is also inseparable from the environment. Under the action of the surrounding environment, the performance of materials will decline, the state will change, and it will be damaged and deteriorated. This is corrosion. The corrosion behavior of materials is closely related to environmental conditions. Where there is a considerable concentration of chemically corrosive gases or vapors, especially when condensation occurs due to moisture, various forms of corrosion are provided for the occurrence and development of environmental conditions to accelerate materials (especially Corrosion of metal materials) leads to performance degradation or early failure of electrical equipment or components.
In terms of corrosion, according to the corrosive environment, it can be divided into atmospheric corrosion, water corrosion, soil corrosion and chemical medium corrosion.
In general, atmospheric corrosion can also be classified into three categories: atmospheric industrial atmosphere, marine atmosphere, and rural atmosphere; the main influencing factors are humidity, industrial pollution, and salt content.
Water corrosion is mostly water that exists in nature, such as seawater, river water, rainwater, groundwater, etc. Most of these waters are near-neutral media, and the depolarizers in the corrosion process are mainly dissolved oxygen, some polluted water. There may be hydrogen depolarization.
Soil corrosion is generally electrochemical corrosion, and its main influencing factors are moisture, pH value, salt content, oxygen content, water permeability and air permeability, etc., as well as stray current and bacterial activity. Generally, soil corrosion resistivity is commonly used. As an indicator of corrosiveness, the smaller the resistivity, the greater the corrosiveness.
Chemical medium corrosion includes acid, alkali, salt, oxidant, non-electrolyte and melt and other corrosive media. Due to the wide variety and complex conditions, this type of corrosion has become the most complex and difficult to control corrosion problem.
Here, it is mainly aimed at different types (mainly related to flameproof type, increased safety type), different flameproof structures (plane type, stop type, cylindrical type, threaded type), different materials (stainless steel, carbon steel, aluminum, copper And plastic, rubber, coating, etc.) explosion-proof electrical products in the marine salt spray and sulfur dioxide corrosion environment artificial simulation accelerated test to obtain the material corrosion resistance and corrosion environment on the characteristics of explosion-proof structure damage and the impact on electrical explosion-proof safety performance .
In order to ensure the reliable and long-term operation of explosion-proof electrical equipment, it is very important to closely combine the work of reasonable material selection, correct design, careful manufacture and good maintenance. Reasonable selection of materials is the first and foremost part, and environmental factors must be considered when selecting materials. We know that no material is omnipotent, and their applications are conditional. The so-called corrosion resistance is also relative, so we must look at the performance of each material in two. Material selection should be based on specific analysis of the corrosive environment. In order to facilitate the analysis, we selected the most representative (marine atmosphere) salt spray environment and (industrial atmosphere) sulfur dioxide corrosion environment as the simulated environmental conditions for material corrosion characteristics analysis, and analyzed its corrosion characteristics through material corrosion tests. Influence of explosion-proof performance of equipment.
The materials used in explosion-proof electrical equipment usually involve two categories, namely metal materials and non-metal materials. Commonly used metal materials include carbon steel and cast iron, stainless steel, aluminum and aluminum alloys, copper and copper alloys, etc.; non-metallic materials (only organic materials are considered here) There are plastic, rubber, glass fiber reinforced plastic, coating, etc. The corrosion mechanisms of metallic materials and non-metallic materials are different, and the corrosion characterization is also different. The corrosion of metal materials is generally electrochemical corrosion and is easily eroded by chemically corrosive media such as acids, alkalis, and salts; the corrosion of non-metallic materials is purely chemical or physical. ) and radiation to cause material swelling, degradation, deterioration, aging and other damage. The common corrosion forms of metallic materials are mostly manifested by surface features such as uniform corrosion, galvanic corrosion, crevice corrosion and pitting corrosion; non-metallic materials are corroded by changes in physical and mechanical properties (such as strength reduction, softening or hardening, etc.) or appearance. Damage (such as surface blistering, roughening or discoloration, etc.). Understanding the corrosion characteristics and corrosion resistance of materials under different environmental conditions can truly make the best use of materials.
Three grades of stainless steel, 321, 302 and 316L, were selected for the corrosion test. Although their corrosion in the humid SO2 and salt spray environment is electrochemical corrosion, the corrosion form in the humid SO2 environment is mainly uniform corrosion, while The form of corrosion in the salt spray environment is mainly localized corrosion. For example, the explosion-proof junction box made of 321 stainless steel has uniform corrosion on the surface of the sample after the SO2 corrosion test, but basically no corrosion on the surface of the sample after the salt spray test. Corrosion patterns in corrosive media are different.
Influence of SO2 corrosive environment on stainless steel
Different grades of stainless steel have different corrosion resistance in the same environment. Comparing 316L, 321 and 302 grades of stainless steel from the surface corrosion of the samples, exposed to SO2 gas corrosion environment, the corrosion resistance of 316L is obviously better than that of 321 and 302, while the surfaces of 321 and 302 samples show obvious corrosion. This means that they are not resistant to moisture SO2 corrosion.
The same grade of stainless steel has different corrosion resistance due to different protective conditions. For example, the shell of the explosion-proof anti-corrosion lamp with the grade of 321 has different corrosion conditions on the inner and outer surfaces due to the direct exposure and the protection conditions of the rubber sealing ring. After the corrosion test, the inner surface of the lamp shell is bright as new, indicating that The rubber sealing ring between the lamp body and the lampshade effectively blocks the immersion of SO2 corrosive gas, while the directly exposed outer surface of the lamp has rust in pieces.
Under the same environmental conditions, the same grade of stainless steel has different corrosion resistance due to different surface conditions. 316L is a stainless steel material with excellent corrosion resistance, but for example, the explosion-proof control button with the same grade of 316L and the F027 sample have large corrosion differences due to different surface conditions. The surface of the explosion-proof control button sample has a silver-white coating. The coating is thin and the surface state of the sample is not uniform due to the existence of local peeling defects, thereby promoting the occurrence and development of corrosion. Stainless steel generally has good corrosion resistance, and its surface is not suitable for coating when used as a structural material.
Influence of salt spray corrosion environment on stainless steel
Stainless steel is originally a material with good corrosion resistance, but in the salt spray environment, the passivation film on the surface of the stainless steel tends to be destroyed due to the presence of a large amount of Cl-, and the destroyed passivation film in the salt spray environment The ability to repair is reduced, which is the root cause of localized corrosion of stainless steel in the salt spray environment. The common local corrosion forms of stainless steel in salt spray environment include galvanic corrosion, crevice corrosion and pitting corrosion.
In the salt spray corrosion environment, the surface of the stainless steel sample basically did not undergo large-scale uniform corrosion, but the corrosion rust formed along the bolts was clearly visible, and the corrosion of all fastening bolts, washers and external grounding was relatively serious. Differences between the material of the bolts, washers, and external grounding and the material of the sample. In a corrosive environment, the contact of dissimilar metals with different potentials will generate a potential difference to form a galvanic couple, thereby accelerating the corrosion of the negative potential metal (anode), that is, galvanic corrosion. Therefore, the fasteners and grounding of the stainless steel shell should be made of the same material to avoid the occurrence of galvanic corrosion. In the design of explosion-proof electrical structure, the contact of dissimilar metals should be avoided as much as possible to cause galvanic corrosion. If it must be used, insulating pads (such as rubber and plastic) should be used to separate dissimilar metals. In addition, for explosion-proof electrical equipment made of stainless steel, the gap between the nameplate and the surface of the shell and the gap between the plane explosion-proof joints create conditions for crevice corrosion. Generally, crevice corrosion is most likely to occur in environments containing Cl-. The oxygen-deficient area is in an occluded state. With the occurrence and development of corrosion, the Cl- concentration in the crack increases, the pH value decreases, and the corrosion is accelerated. Although the crevice is the main design defect that causes corrosion, the crevice between the flameproof joint surfaces is unavoidable in the design, and grease with corrosion inhibitor can be applied to prevent crevice corrosion.
Both carbon steel and cast iron are iron-carbon alloys, which are inexpensive and have good mechanical and technological properties, especially carbon steel, which is widely used in structural materials for explosion-proof electrical products. In terms of corrosion resistance, its chemical stability is low. In practical applications, corrosion-resistant metal coatings or anti-corrosion measures such as paint protection are used to improve its corrosion resistance. The corrosion test is made of Q235A carbon steel.
Q235A is ordinary carbon steel, and its surface should be coated with a protective coating when used in a corrosive environment. After the SO2 corrosion test and the salt spray corrosion test, the surface coating of the sample is basically intact, but the surface corrosion of the nameplate, fastening bolts and washers is not well-coated or not protected. The plane or port-type flameproof joint of flameproof explosion-proof electrical equipment is bounded by the "O-type" rubber sealing ring. The outer part is corroded, and the inner part is not corroded. In addition, the flameproof joint after salt spray corrosion The surface corrosion is relatively light, while the corrosion of the flameproof joint surface after SO2 corrosion is more serious, which shows that the Q235A carbon steel has better resistance to salt spray corrosion than SO2 corrosion resistance.
The industrial application of aluminum alloy is second only to steel materials, and it is one of the most commonly used structural materials for the manufacture of explosion-proof electrical equipment. This is not only because of its light weight and low price, but also because of its surface The alumina protective film becomes a good protective barrier layer. The standard potential of aluminum is very negative, and it is a thermodynamically active metal. If it is used in a chemically corrosive environment, it is definitely not corrosion-resistant. Therefore, when using aluminum explosion-proof electrical equipment in a chemically corrosive environment, the surface must be designed with an anti-corrosion layer. For the corrosion test, aluminum materials with grades ZL102 and YL104 were selected.
The corrosion resistance of aluminum depends to a large extent on the surrounding environment and the stability of the surface oxide film in the medium. Moist SO2 can accelerate the corrosion of aluminum, but compared with Fe and Cu under the same conditions, aluminum is still corrosion resistant. The corrosion resistance of aluminum electrical equipment in SO2 corrosive environment mainly depends on the properties of its surface protective coating. After the SO2 gas corrosion test, the surface coating of the sample did not corrode significantly, and the underlying metal aluminum did not corrode, indicating that the coating Played the due protective effect.
In the marine salt spray environment, aluminum is not resistant to corrosion in the salt spray environment containing Cl- because Cl- can destroy its passivation film and is prone to pitting corrosion. The radius of Cl- is small, and its ability to penetrate and diffuse into the interior through the micropores of the coating is relatively strong. At the same time, Cl- is extremely corrosive to metal aluminum. Therefore, after corroding the surface coating, it continues to corrode the base metal. The product is loose and expands in volume, which further promotes cracking, peeling and peeling of the surface coating. After salt spray test, almost all aluminum explosion-proof electrical equipment not only has quality defects such as serious bubbling, warping, peeling, and falling off on the outer surface coating/plating, but also the bottom metal aluminum is also severely corroded. The damage starts from the corners, which fully illustrates the corner effect of the coating, that is, the corners are the weakest and most prone to quality defects of the coating.
Metal aluminum is very sensitive to chloride ions. After corrosion, a layer of white powdery corrosion products is formed on the surface, which has a great impact on the threaded structure. The threads of the aluminum alloys cannot be opened due to severe corrosion, and the fasteners (such as bolts, nuts) and threaded parts of all aluminum samples in the salt spray environment are blocked by corrosion products, which brings great inconvenience to the disassembly of all threaded structures. Due to the presence of a large amount of Cl- in the salt spray environment, Al is severely corroded, so aluminum explosion-proof electrical equipment is not suitable for use in the salt spray environment.
Under atmospheric conditions, copper is relatively stable; in humid SO2, the corrosion of copper is intensified. At this time, a film of CuSO4 3Cu(OH)2 alkaline copper sulfate is formed on the surface of copper. This film has no Protective effect; in the marine atmosphere, in addition to the formation of alkaline copper sulfate CuSO4 3Cu(OH)2 on the surface of copper, there is also alkaline copper chloride CuCl2 3Cu(OH)2. Widely used in practice are copper alloys—brass, bronze, and especially bronze, often used as corrosion-resistant structural materials. For the corrosion test, ordinary brass H59 was selected, and the test showed that it is not resistant to corrosion by salt spray and humid SO2 medium. The material of the explosion-proof junction box is H59. After the corrosion test, the surface coating of the junction box does not change significantly, but the surface of the copper nameplate is also corroded even after the coating treatment. In the salt spray environment, it corrodes and turns white; the junction box flameproof joint surface shows obvious corrosion whether in the SO2 environment or in the salt spray environment, and the corrosion occurs outside the "O-type" rubber sealing ring. The plane part, while the cylindrical part inside the "O-type" rubber sealing ring has no corrosion, which means that the "O-type" rubber sealing ring blocks the channel for the inward diffusion of corrosive gas and plays a protective role. In addition, the surface of the copper sealing stuffing box of the explosion-proof junction box has not been subjected to any protective treatment, and is directly exposed to the corrosive environment. In the SO2 environment, the corrosion is black, while in the salt spray environment, patina corrosion products appear. From the above analysis, it is not difficult to see that copper and copper alloys should not be directly exposed to corrosive environments, that is to say, copper explosion-proof electrical appliances should be surface protected when used in corrosive environments, and their corrosion resistance depends on the properties of the surface coating and paint quality.
Plastic is a type of polymer material that is mainly composed of resin, and can be plasticized and formed during processing with appropriate additives. Therefore, it can also be said that plastic is a polymer product dominated by resin. Plastic materials are widely used in the manufacture of explosion-proof electrical equipment due to their excellent processing properties, corrosion resistance and electrical insulation properties. For electrical insulating materials, their dielectric properties, heat resistance and flame retardancy must exceed the specified index by an appropriate range to increase their safety factor to prevent local heating or breakdown caused by excessive voltage and current, resulting in fire, explosion accident. On the other hand, plastics have good electrical insulation properties and are prone to electrostatic accumulation. Measures should be taken to ensure their safety when used in flammable and explosive environments.
The test selected several plastic materials commonly used in explosion-proof electrical equipment, such as polyhexamethylene adipamide (polyamide-66), polyvinyl chloride plastic (PVC), acrylonitrile-butadiene-styrene copolymer (ABS engineering Plastics), polycarbonate plastics (PC), unsaturated polyester sheet molding compounds (SMC), unsaturated polyester bulk molding compounds (DMC), etc., which show better performance in SO2 and salt spray corrosion environments Therefore, under the premise of meeting the technical requirements of explosion-proof, plastic materials can be used as structural materials for explosion-proof electrical equipment in corrosive environments.
After the corrosion test, the plastic shell of the sample is basically free of corrosion, but all the metal parts (fasteners, nameplates, etc.) in the sample show obvious corrosion; Corrosion of metal parts) indicates that corrosive media has entered the interior, so the corrosion of internal components depends on the protection performance of the sample. In addition, some samples of unsaturated polyester molding compounds (SMC, DMC) have discoloration and roughening on the surface after SO2 corrosion test, but there is no change after salt spray corrosion test, which shows that SMC and DMC materials are resistant to salt spray. The performance is better than that of SO2 corrosion resistance.
Although plastic materials have many advantages and good comprehensive performance, they often cannot or should not be used under certain conditions. Plastics cannot be used when the material strength is particularly high. The use temperature range of plastic materials is narrow, and plastics should not be used when the use temperature is too high or too low. This is because plastic is a viscoelastic material that is extremely sensitive to temperature changes. Generally, the mechanical properties, electrical properties and corrosion resistance of plastic materials decrease with the increase of temperature, and when the temperature is too low, the plastic material will become hard, brittle, easy to crack, and even lose its performance. In addition to ambient temperature, humidity and medium conditions, the selection of plastic materials should also consider environmental factors such as light, oxygen, and radiation. Under the environment of light, oxygen and radiation, plastic products will cause plastic degradation reaction (ie aging), resulting in the decline of the performance of plastic products, thus greatly shortening their service life. Therefore, explosion-proof electrical equipment made of plastic materials should not be exposed to outdoor use for a long time.
The coating generally refers to the non-metallic coating (including organic coatings and inorganic coatings) covering the metal surface; and the coating refers to the metal covering such as electroplating, hot dip plating, and electroless plating on the metal surface. That is, the metal/alloy or coating with strong corrosion resistance is used to cover the metal with weak corrosion resistance to achieve the purpose of anti-corrosion. Coating and plating combine the excellent properties of both the protective layer and the protected layer, such as the corrosion resistance, wear resistance and oxidation resistance of the protective layer, and the strength and stiffness of the protected layer. Compared with the non-metallic protective layer, the metal protective layer has the advantages of high strength and good heat resistance, and the non-metallic protective layer has the advantages of convenient construction and good corrosion resistance. The coatings and coatings on the metal surface are generally porous films. Although they cannot completely isolate the metal from the corrosive medium, the existence of the coating and the coating can increase the diffusion resistance and solution resistance of the corrosive medium through the pores, so that the corrosion current can be reduced. down thereby slowing the corrosion of the underlying metal.
The coating and plating on the surface of explosion-proof electrical products is an important protection method used to isolate the base material and the surrounding environment. In the design of coating and coating, materials with good corrosion resistance should be selected according to environmental conditions. At the same time, the coating quality of coating and coating is also directly related to its corrosion resistance and service life. Only those well-coated and coated surfaces can play a role. Due to the protective effect, coatings and coatings with defects such as cracks, mechanical scratches, and local shedding not only have no protective effect, but also accelerate corrosion. In addition, the service life of the coating and plating layer is related to the strong and weak corrosiveness of the environmental medium in the installation site of explosion-proof electrical products. During the service life of explosion-proof electrical equipment, recoating protection can be planned according to the surrounding environmental medium conditions to prolong the explosion-proof electrical equipment. service life.
Rubber is a highly elastic material that can be deformed under the action of external force and can be restored after the external force is removed. Therefore, it is a main sealing structure material. The essence of the rubber seal is to seal the gap between the two contact surfaces by plugging the rubber, that is, the contact surface seal. Rubber is usually used as a seal in explosion-proof electrical equipment. If the seal is permanently deformed under the action of external force, the sealing effect is not good or the sealing performance is lost. Therefore, the permanent deformation of the seal material should be small, the elasticity should be high, the resilience should be strong, and it should have appropriate hardness; the rubber material has certain When the temperature is higher than the limit temperature, the elasticity will be lost due to aging; when the temperature is lower than the limit temperature, the high elastic deformation will be suppressed and the rigidity will be enhanced. Therefore, if the temperature exceeds the operating temperature range, the rubber seal will lose its sealing performance; in addition, it should be noted that Under the action of pressure, temperature and medium, the vulcanized rubber itself will age after a certain period of time, resulting in irreversible deformation and damage to the sealing performance. When it is lost, it should be replaced in time.
Natural rubber is easy to age under the action of oxygen, so natural rubber is rarely used as a seal, and synthetic rubber is usually used as a seal, such as nitrile rubber, neoprene, ethylene propylene rubber, butyl rubber, butadiene rubber, Silicone rubber and fluorine rubber, etc. Different types of rubber seals have different sealing properties. When selecting materials, various properties such as tensile strength, permanent deformation, hardness, temperature resistance, medium resistance, and permeability should be considered, and selected according to actual working conditions. , in order to improve the sealing effect. Nitrile rubber is a copolymer of butadiene and acrylonitrile. It has excellent oil resistance. It also has the mechanical strength and wear resistance required as a sealing material. It is widely used in various seals; neoprene is a kind of The polarity is second only to the self-reinforcing elastomer of nitrile rubber. It is the best kind of general-purpose rubber, and it is a flame-retardant rubber. Ethylene-propylene rubber is a copolymer of ethylene and propylene. Halo performance is very outstanding, and the price is cheap; Butyl rubber is made of isobutylene and isoprene copolymerization, the most prominent feature is low air permeability, is the best air tightness rubber, can be used for vacuum sealing; Rubber is a general-purpose synthetic rubber polymerized from butadiene as raw material. The glass transition temperature of high cis-butadiene rubber is as low as -105 °C, so it has good low temperature resistance and is an excellent material for making sealing products in low-cold areas. Good flexibility, especially suitable for sealing needs to withstand multiple deformations; silicone rubber has a wide operating temperature range (-100 ° C ~ +350 ° C), good air permeability, but its shortcomings are low strength and high price; fluorine rubber The biggest feature is high corrosion resistance, its high temperature resistance is comparable to that of silicone rubber, and it has excellent high vacuum resistance.
The corrosion test uses nitrile rubber. After the corrosion test of the sample, the surface of the sample has no corrosion characteristics such as delamination, brittle cracking, deformation and stickiness. The hardness change rate of the rubber sample before and after the test in the SO2 environment is 4.4%. The hardness change rate of the rubber samples before and after the test in the environment is 4.1%, which meets the requirements of relevant standards, indicating that the nitrile rubber has excellent corrosion resistance in SO2 and salt spray environments. Material corrosion test results show that non-metallic materials have better corrosion resistance than metal materials in chemically corrosive environments. As far as metal materials are concerned, Fe corrodes more seriously than Al in SO2 environment, while Al corrodes more seriously than Fe in salt spray environment; stainless steel corrodes more seriously in SO2 environment than in salt spray environment; copper and copper alloys corrode more in SO2 environment. Corrosion was evident in both the copper and the salt spray environment, the copper surface corroded and turned black in the SO2 environment, and patina appeared in the salt spray environment. The surface of ordinary metal materials (such as carbon steel, aluminum, copper, etc.) used in corrosive environments should be designed with protective coatings, and attention should also be paid to strengthening the sealing protection of the casing structure to avoid the intrusion of corrosive media.
The effect of corrosion on flameproof jointsof explosion proof electrical equipment
The standard GB3836.2-2010 stipulates that "the average surface roughness Ra of the joint surface shall not exceed 6.3μm". After the corrosion test, the flameproof joint surface of some flameproof explosion-proof electrical equipment is corroded, and the average surface roughness far exceeds the standard value and cannot meet the explosion-proof requirements.
Tests show that among several different types of flameproof joints, the corrosion of the flat flameproof joint is the most serious, while the corrosion of the cylindrical, spigot and threaded flameproof joints is relatively light. The corrosion of explosion-proof joints is related to the ease with which corrosive gases come into contact with explosion-proof joints. From the structural point of view of the flameproof joint surface, the path for corrosive gas to enter the flameproof cavity through the plane and cylindrical joint surfaces is linear; the path through the port type is "L" shape; the path through the threaded type For the zigzag line, it is obvious that the corrosive medium is the easiest to pass through the flat and cylindrical joint surfaces, followed by the spigot type, and the threaded type is the most difficult. In addition, whether it is a plane type or a spigot type flameproof joint, the plane part outside the "O-type" rubber seal is severely corroded, while the part inside the "O-type" rubber seal has no corrosion. The test results show that, If an "O" ring is set on the flameproof joint surface, it can block the passage of the corrosive medium from diffusing into the flameproof cavity. Corrosive medium entering the cavity affects the performance and life of the internal electrical components.
The explosion-proof joint surface of explosion-proof explosion-proof electrical equipment is not allowed to be painted, only grease is allowed. Grease will lose its anti-corrosion effect when used in a corrosive environment for a long time. Therefore, explosion-proof electrical equipment should be regularly cleaned during its service life. The flameproof joint surface shall be oiled and maintained.
Influence of Corrosion on Strength of Explosion-Proof Electrical Enclosures
After the salt spray corrosion test, the surface coating of aluminum explosion-proof electrical equipment is severely peeled and peeled off. After the coating is peeled off, the salt spray further corrodes the underlying metal, which will lead to changes in the strength and mechanical properties of the shell over time. For example, after some aluminum electrical equipment is subjected to the salt spray test, and then the impact test specified in GB3836.1-2010 and the explosion test specified in GB3836.2-2010, the sample ruptures and does not meet the requirements of explosion-proof performance.
Effects of Corrosion on Explosion-Proof Electrical Fasteners
The strength of fasteners is particularly important for the explosion-proof performance of flameproof electrical equipment. Clause 11 of the standard GB3836.2-2010 (equivalent to IEC60079-1:2007) specifies that the minimum yield stress of fasteners is 240N/mm2. After the corrosion test, most fasteners are corroded to varying degrees, and the yield stress of the corroded fasteners must change, which is likely to fail to meet this requirement. Therefore, the material of the fasteners of explosion-proof electrical equipment used in corrosive environments must also be resistant to corrosion.
Influence on the internal wiring terminals of explosion-proof electrical equipment
GB3836.3-2010 stipulates that the temperature of electrical equipment components does not exceed the maximum surface temperature specified in GB3836.1-2010. Corrosion of the terminals will inevitably cause the contact resistance to increase, resulting in an increase in temperature, so that the terminals that originally meet the temperature group exceed the specified maximum surface temperature and fail to achieve the original explosion-proof performance. An effective way to prevent corrosion of internal terminals is to enhance the sealing performance of the protective structure of the housing to achieve IP54 or IP55 protection level.
The effect of corrosion on explosion-proof electrical nameplates
GB3836.3-2010 stipulates that the temperature of electrical equipment components does not exceed the maximum surface temperature specified in GB3836.1-2010. Corrosion of the terminals will inevitably cause the contact resistance to increase, resulting in an increase in temperature, so that the terminals that originally meet the temperature group exceed the specified maximum surface temperature and fail to achieve the original explosion-proof performance. An effective way to prevent corrosion of internal terminals is to enhance the sealing performance of the protective structure of the housing to achieve IP54 or IP55 protection level.
Corrosive environmental conditions and their test standards
GB4796 is the classification of environmental parameters of electrical and electronic products and the grading standard of severity. GB4797 and GB4798 series of standards are the environmental conditions and application environmental conditions of electrical and electronic products respectively. Most of these standards are equivalent or modified to adopt the IEC60721 series of the International Electrotechnical Commission Standard; GB2423 series standards are environmental test series standards for electrical and electronic products in my country. Most of this series of standards are equivalent or modified to adopt IEC60068 series standards of the International Electrotechnical Commission. method; in addition, there are a series of JB standards that can be used with reference.
Test methods for different anti-corrosion grades
Explosion-proof electrical equipment is used under different environmental conditions such as chemical corrosion and will be affected by environmental corrosion. Therefore, on the basis of reasonable selection of materials, correct design, and careful manufacture, explosion-proof electrical products should pass relevant explosion-proof type tests and corresponding environmental tests according to the expected environmental conditions to verify their reliability scientifically, and based on the corrosion results obtained by artificial simulated environmental tests Trends and approximate results, scientifically guide the development, manufacture, selection and use of explosion-proof electrical products. The environmental tests involved in different anti-corrosion levels usually include damp heat test, chemical gas corrosion test and comprehensive test of different combinations of environmental factors.
The reliability of explosion-proof and light-corrosion-proof electrical products that are fixed in places without climate protection can usually be verified by damp heat test. Generally speaking, the corrosion rate increases as the relative humidity increases. The test method of the damp heat test can be carried out according to the provisions of GB/T2423.4. The severity level of the damp heat test is determined by the combination of high temperature (55°C or 40°C) and different test cycles, which can be appropriately selected according to the product use environment. Before the test, during the test and after the test, the samples should be visually inspected and performance tested according to the relevant requirements, so as to determine the environmental adaptability, electrical and mechanical properties of the explosion-proof and light-corrosion-proof electrical products that are used in non-climate protected places. changes.
Explosion-proof and medium-corrosion-proof electrical products that are used in non-climate protection places and places with climate protection should at least pass 2 cycles of sulfur dioxide gas corrosion test to verify their reliability; Strongly corrosive electrical products should at least pass a 10-cycle sulfur dioxide gas corrosion test to verify their reliability. The test method of the corrosion test can be carried out according to the provisions of GB2423.33. Before the test, during the test and after the test, the appearance inspection and performance test of the sample should be carried out according to the relevant requirements. If the appearance or function of the sample has been damaged due to corrosion during the test process , the test can be terminated, and it can be determined that the test sample is not suitable for chemical corrosion environment.
The reliability of explosion-proof electrical products used in the marine salt spray environment shall be verified through the corresponding salt spray test. The test method of the salt spray test can be carried out according to the provisions of GB/T2423.17 (Test Ka) or GB/T2423.18 (Test Kb). The test Ka is used to divide the severity level by the duration of continuous salt spray. This test method is suitable for assessing the ability of materials, protective layers and products to resist salt spray corrosion, but it should not be used as a general corrosion test method; test Kb is composed of two Or two or more different environmental stages are combined to form different severity levels, which can more effectively simulate the effect of natural salt spray environment. In addition to showing the corrosion effect of salt spray, it can also show the degree of deterioration of some non-metallic materials due to absorption of salt. , and can also be used as a general corrosion test method.
After the artificial simulated accelerated corrosion test, relevant tests on electrical performance should be carried out according to the technical requirements of the product. For example, in the electrical insulation performance test, it is required that the insulation resistance value between the outer casing of the electrical appliance and the conductive parts and between the conductive parts that are insulated from each other is not less than 2MΩ, and the dielectric properties meet the relevant regulations of the technical standard; After the test, the action and operation performance of the electrical appliance should be flexible and reliable, and the conductive/magnetic conductive elements, metal structural parts and fasteners on the outer casing should not show obvious corrosion (such as patina and rust); the paint layer on the surface of the casing should not appear loose, Obvious bubbling, peeling, peeling and bottom metal corrosion, etc.; plastic casings and plastic parts on the casing shall not be blistered, deformed or brittle; rubber parts shall not be corroded, delaminated, brittle, deformed and sticky, sealing rings and seals The hardness change value of the gasket shall not be greater than 20% of that before the test; the nameplate shall not corrode, lift or fall off, and the writing on the nameplate shall be clear; the flameproof surface of the flameproof electrical appliance shall not be corroded; the conductive parts and fasteners in the junction box shall not be corroded. There must be no visible corrosion.
Other Corrosion environment test
In addition to the above-mentioned different anti-corrosion grade judgment tests, there are many other environmental tests, such as temperature test (including low temperature test, high temperature test and temperature change test), low pressure test radiation test (mainly solar radiation and thermal radiation), mold test , Vibration test, tilt and swing test, impact test, noise test, electromagnetic compatibility test, etc., can be appropriately selected according to different places of use. It is important to point out that non-metallic materials are very sensitive to temperature and sunlight. Especially when the working environment is close to the limit temperature of the material, or when the product generates heat during use, or when there is a temperature change, the temperature test cannot be ignored. when it is used under sunlight (ultraviolet) irradiation conditions, the light test cannot be ignored.
CESP anti-corrosion led lights and electronics equipment are made of Material _1: Stainless steel, Material_3: Aluminum and aluminum alloys and Material_6: "Coating, plating" used for anti-corrosion, then the the products throught electrophoresis technology, are coated with a non-metallic paint-like coating on the surface of the housing, which makes the appearance of the lamp flat, smooth, corrosion-resistant and impact-resistant. Then, apply multiple coats of marine anti-corrosion paint to enhance corrosion resistance. That can protect the lamps and equipment from long-term harsh salt water and atmospheric corrosion in the marine environment.
These items can applied to the marine environment, such as the Offshore Engineering, Offshore Facilities, Offshore Oil Platforms and seagoing vessel. In additional, it suitable for some chemical plants, sewage treatment plants are relatively harsh and corrosive environments.
Corrosion starts from the deterioration of material properties, which in turn affects the explosion-proof performance of electrical equipment. Environmental testing is an important means to ensure the quality of explosion-proof electrical products. It can discover potential quality hazards of explosion-proof electrical products and improve the safety and reliability of explosion-proof electrical products.