Explosion Proof LED Linear Light - ATEX IECEx Zone 1 Zone 2 - 480W 600W

 

Applications

Wastewater treatment,oil and gas refineries, drilling rigs, petrochemical facilities, food and beverage facilities, tunnels, outdoor wall and stanchion mounted general area lighting, and where flammable vapors, gases, ignitable dusts, fibers or flyings are present.

Standard :
ATEX: EN IEC 60079-0-2018; EN 60079-7-2015; EN 60079-31-2014;
IECEx: IEC 60079-0-2017; IEC 60079-7-2015; IEC 60079-31-2013;

Warning

IECEx& ATEX :

  • “WARNING – DO NOT OPEN WHEN ENERGIZED”;
  • “WARNING – DO NOT OPEN WHEN AN EXPLOSIVE ATMOSPHERE IS PRESENT”;
  • “WARNING – Potential Electrostatic Charging Hazard –Please wipe with a damp cloth when cleaning”;
  • End user shall use certified cable gland suitable type of protection for final installation purpose;
  • External earthing wire shall be connected when used and the cross-sectional area shall be more than 4mm²or 10AWG;
  • Under rating condition, maximum temperature on the luminaire’s shell shall not be higher than 165℃ for T3. Temperature at cable inlet shall not be higher than allowable limit of the cable applied, to ensure the cable operation normally. For CES-EX-LN-02-80、CES-EX-LN-02-100、CES-EX-LN-02-120、CES-EX-LN-02-150, the branch point is 78.4℃ and cable entry point is 66.8℃

Features

  • Luminous flux: 62400LM / 78000LM
  • -40°C to + 50°C Ambient operating temperature
  • 5 years warranty
  • Entry Size: M25 X 1.5
  • Housing – Aluminum alloy (ADC12 and 6063)
  • Lens – Tempered glass
  • LED Driver: Meanwell HLG series

Parameters

  • Power: 480W / 600W
  • Input voltage: AC100-240/277V, 50/60Hz
  • Power factor: 0.97
  • Light efficacy: 120 - 140lm/W
  • CCT: 3000K/4000K/5000K/5700K/6500K
  • LEDs: 3030
  • Bean angle: 90° or 110°
  • Dimension: 564*202*112mm (Single Fixture)
  • Weight: 10.6KG (Single Fixture)

Certificate & Standard

IECEx Certificate No. :  IECEx UL 22.0091X

  •  Ex ec IIC T *Gc
  •  Ex tb IIIC T *°C Db
  •  IP66

IECEx Certificate No. : ATEX Certificate No.: UL 22 ATEX 2543X, UL 22 ATEX 2544X

  •  II 3G Ex ec IIC T*Gc
  •  II 2D Ex tb IIIC T*Db
  •  IP66

Mounting

Versatile mounting options:

  • Ceiling mount
  • Drop mount
  • Wall Mount
  • Mounting Angle:0°to ±90°

Explosion Proof LED Linear Light - ATEX IECEx Zone 1 Zone 2 - 360W 400W

 

Applications

Wastewater treatment,oil and gas refineries, drilling rigs, petrochemical facilities, food and beverage facilities, tunnels, outdoor wall and stanchion mounted general area lighting, and where flammable vapors, gases, ignitable dusts, fibers or flyings are present.

Standard :
ATEX: EN IEC 60079-0-2018; EN 60079-7-2015; EN 60079-31-2014;
IECEx: IEC 60079-0-2017; IEC 60079-7-2015; IEC 60079-31-2013;

Warning

IECEx& ATEX :

  • “WARNING – DO NOT OPEN WHEN ENERGIZED”;
  • “WARNING – DO NOT OPEN WHEN AN EXPLOSIVE ATMOSPHERE IS PRESENT”;
  • “WARNING – Potential Electrostatic Charging Hazard –Please wipe with a damp cloth when cleaning”;
  • End user shall use certified cable gland suitable type of protection for final installation purpose;
  • External earthing wire shall be connected when used and the cross-sectional area shall be more than 4mm²or 10AWG;
  • Under rating condition, maximum temperature on the luminaire’s shell shall not be higher than 165℃ for T3. Temperature at cable inlet shall not be higher than allowable limit of the cable applied, to ensure the cable operation normally. For CES-EX-LN-02-80、CES-EX-LN-02-100、CES-EX-LN-02-120、CES-EX-LN-02-150, the branch point is 78.4℃ and cable entry point is 66.8℃

Features

  • Luminous flux: 46800LM / 52000LM
  • -40°C to + 50°C Ambient operating temperature
  • 5 years warranty
  • Entry Size: M25 X 1.5
  • Housing – Aluminum alloy (ADC12 and 6063)
  • Lens – Tempered glass
  • LED Driver: Meanwell HLG series

Parameters

  • Power: 360W / 400W
  • Input voltage: AC100-240/277V, 50/60Hz
  • Power factor: 0.97
  • Light efficacy: 120 - 140lm/W
  • CCT: 3000K/4000K/5000K/5700K/6500K
  • LEDs: 3030
  • Bean angle: 90° or 110°
  • Dimension: 564*202*112mm (Single Fixture)
  • Weight: 10.6KG (Single Fixture),Total 31.8KG

Certificate & Standard

IECEx Certificate No. :  IECEx UL 22.0091X

  •  Ex ec IIC T *Gc
  •  Ex tb IIIC T *°C Db
  •  IP66

IECEx Certificate No. : ATEX Certificate No.: UL 22 ATEX 2543X, UL 22 ATEX 2544X

  •  II 3G Ex ec IIC T*Gc
  •  II 2D Ex tb IIIC T*Db
  •  IP66

Mounting

Versatile mounting options:

  • Ceiling mount
  • Drop mount
  • Wall Mount
  • Mounting Angle:0°to ±90°

Explosion Proof LED Linear Light - ATEX IECEx Zone 1 Zone 2 - 200W 240W 300W

 

Applications

Wastewater treatment,oil and gas refineries, drilling rigs, petrochemical facilities, food and beverage facilities, tunnels, outdoor wall and stanchion mounted general area lighting, and where flammable vapors, gases, ignitable dusts, fibers or flyings are present.

Standard :
ATEX: EN IEC 60079-0-2018; EN 60079-7-2015; EN 60079-31-2014;
IECEx: IEC 60079-0-2017; IEC 60079-7-2015; IEC 60079-31-2013;

Warning

IECEx& ATEX :

  • “WARNING – DO NOT OPEN WHEN ENERGIZED”;
  • “WARNING – DO NOT OPEN WHEN AN EXPLOSIVE ATMOSPHERE IS PRESENT”;
  • “WARNING – Potential Electrostatic Charging Hazard –Please wipe with a damp cloth when cleaning”;
  • End user shall use certified cable gland suitable type of protection for final installation purpose;
  • External earthing wire shall be connected when used and the cross-sectional area shall be more than 4mm²or 10AWG;
  • Under rating condition, maximum temperature on the luminaire’s shell shall not be higher than 165℃ for T3. Temperature at cable inlet shall not be higher than allowable limit of the cable applied, to ensure the cable operation normally. For CES-EX-LN-02-80、CES-EX-LN-02-100、CES-EX-LN-02-120、CES-EX-LN-02-150, the branch point is 78.4℃ and cable entry point is 66.8℃

Features

  • Luminous flux: 26000LM / 31200LM / 39000LM
  • -40°C to + 50°C Ambient operating temperature
  • 5 years warranty
  • Entry Size: M25 X 1.5
  • Housing – Aluminum alloy (ADC12 and 6063)
  • Lens – Tempered glass
  • LED Driver: Meanwell HLG series

Parameters

  • Power: 200W / 240W / 300W
  • Input voltage: AC100-240/277V, 50/60Hz
  • Power factor: 0.97
  • Light efficacy: 120 - 140lm/W
  • CCT: 3000K/4000K/5000K/5700K/6500K
  • LEDs: 3030
  • Bean angle: 90° or 110°
  • Dimension: 564*202*112mm (Single Fixture)
  • Weight: 10.6KG

Certificate & Standard

IECEx Certificate No. :  IECEx UL 22.0091X

  •  Ex ec IIC T *Gc
  •  Ex tb IIIC T *°C Db
  •  IP66

IECEx Certificate No. : ATEX Certificate No.: UL 22 ATEX 2543X, UL 22 ATEX 2544X

  •  II 3G Ex ec IIC T*Gc
  •  II 2D Ex tb IIIC T*Db
  •  IP66

Mounting

Versatile mounting options:

  • Ceiling mount
  • Drop mount
  • Wall Mount
  • Mounting Angle:0°to ±90°

Explosion Proof LED Linear Light - ATEX IECEx Zone 1 Zone 2 - 80W 100W 120W 150W

 

Applications

Wastewater treatment,oil and gas refineries, drilling rigs, petrochemical facilities, food and beverage facilities, tunnels, outdoor wall and stanchion mounted general area lighting, and where flammable vapors, gases, ignitable dusts, fibers or flyings are present.

Standard :
ATEX: EN IEC 60079-0-2018; EN 60079-7-2015; EN 60079-31-2014;
IECEx: IEC 60079-0-2017; IEC 60079-7-2015; IEC 60079-31-2013;

Warning

IECEx& ATEX :

  • “WARNING – DO NOT OPEN WHEN ENERGIZED”;
  • “WARNING – DO NOT OPEN WHEN AN EXPLOSIVE ATMOSPHERE IS PRESENT”;
  • “WARNING – Potential Electrostatic Charging Hazard –Please wipe with a damp cloth when cleaning”;
  • End user shall use certified cable gland suitable type of protection for final installation purpose;
  • External earthing wire shall be connected when used and the cross-sectional area shall be more than 4mm²or 10AWG;
  • Under rating condition, maximum temperature on the luminaire’s shell shall not be higher than 165℃ for T3. Temperature at cable inlet shall not be higher than allowable limit of the cable applied, to ensure the cable operation normally. For CES-EX-LN-02-80、CES-EX-LN-02-100、CES-EX-LN-02-120、CES-EX-LN-02-150, the branch point is 78.4℃ and cable entry point is 66.8℃

Features

  • Luminous flux: 10400LM / 13000LM / 15600LM / 19500LM
  • -40°C to +50°C Ambient operating temperature
  • 5 years warranty
  • Entry Size: M25 X 1.5
  • Housing – Aluminum alloy (ADC12 and 6063)
  • Lens – tempered glass
  • LED Driver: Meanwell HLG series

Parameters

  • Power:80W/100W/120W / 150W
  • Input voltage: AC100-240/277V, 50/60Hz
  • Power factor: 0.97
  • Light efficacy: 120 - 140lm/W
  • CCT: 3000K/4000K/5000K/5700K/6500K
  • LEDs: 3030
  • Bean angle: 90° or 110°
  • Dimension: 564*202*112mm
  • Weight: 10.6KG

Certificate & Standard

IECEx Certificate No. :  IECEx UL 22.0091X

  •  Ex ec IIC T *Gc
  •  Ex tb IIIC T *°C Db
  •  IP66

IECEx Certificate No. : ATEX Certificate No. : UL 22 ATEX 2543X, UL 22 ATEX 2544X

  •  II 3G Ex ec IIC T*Gc
  •  II 2D Ex tb IIIC T*Db
  •  IP66

Mounting

Versatile mounting options:

  • Ceiling mount
  • Drop mount
  • Wall Mount
  • Mounting Angle:0°to ±90°

Explosion Proof LED Linear Light - ATEX IECEx Zone 1 Zone 2 - 40W 50W 60W

 

Applications

Wastewater treatment,oil and gas refineries, drilling rigs, petrochemical facilities, food and beverage facilities, tunnels, outdoor wall and stanchion mounted general area lighting, and where flammable vapors, gases, ignitable dusts, fibers or flyings are present.

Standard :
ATEX: EN IEC 60079-0-2018; EN 60079-7-2015; EN 60079-31-2014;
IECEx: IEC 60079-0-2017; IEC 60079-7-2015; IEC 60079-31-2013;

Warning

IECEx& ATEX :

  • “WARNING – DO NOT OPEN WHEN ENERGIZED”;
  • “WARNING – DO NOT OPEN WHEN AN EXPLOSIVE ATMOSPHERE IS PRESENT”;
  • “WARNING – Potential Electrostatic Charging Hazard –Please wipe with a damp cloth when cleaning”;
  • End user shall use certified cable gland suitable type of protection for final installation purpose;
  • External earthing wire shall be connected when used and the cross-sectional area shall be more than 4mm²or 10AWG;
  • Under rating condition, maximum temperature on the luminaire’s shell shall not be higher than 165℃ for T3. Temperature at cable inlet shall not be higher than allowable limit of the cable applied, to ensure the cable operation normally. For CES-EX-LN-02-40、CES-EX-LN-02-50、CES-EX-LN-02-60, the branch point is 61.8℃ and cable entry point is 57.5℃.
 

Features

  • Luminous flux: 5200LM / 6500LM / 7800LM
  • -40°C to +50°C Ambient operating temperature
  • 5 years warranty
  • Entry Size: M25 X 1.5
  • Housing –Aluminum alloy (ADC12 and 6063)
  • Lens –tempered glass
  • LED Driver: Meanwell HLG series

Parameters

  • Power:40W/50W/60W
  • Input voltage: AC100-240/277V, 50/60Hz
  • Power factor: 0.97
  • Light efficacy: 120 - 140lm/W
  • CCT: 3000K/4000K/5000K/5700K/6500K
  • LEDs: 3030
  • Bean angle: 90° or 110°
  • Dimension: 596*126*114mm
  • Weight: 7.5KG

Certificate & Standard

IECEx Certificate No. :  IECEx UL 22.0091X

  •  Ex ec IIC T *Gc
  •  Ex tb IIIC T *°C Db
  •  IP66

IECEx Certificate No. : ATEX Certificate No. : UL 22 ATEX 2543X, UL 22 ATEX 2544X

  •  II 3G Ex ec IIC T*Gc
  •  II 2D Ex tb IIIC T*Db
  •  IP66

Mounting

Versatile mounting options:

  • Ceiling mount
  • Drop mount
  • Wall Mount
  • Mounting Angle:0°to ±90°

Zone 21 Explosion Proof LED Light  - ATEX IECEx - 30W 40W

 

Applications

Wastewater treatment,oil and gas refineries, drilling rigs, petrochemical facilities, food and beverage facilities, tunnels, outdoor wall, and stanchion mounted general area lighting, and where flammable vapors, gases, ignitable dusts, fibers or flyings are present.

Standard :
ATEX: EN IEC 60079-0-2018; EN 60079-7-2015; EN 60079-31-2014;
IECEx: IEC 60079-0-2017; IEC 60079-7-2015; IEC 60079-31-2013;

Warning

IECEx& ATEX :

  • “WARNING – DO NOT OPEN WHEN ENERGIZED”;
  • “WARNING – DO NOT OPEN WHEN AN EXPLOSIVE ATMOSPHERE IS PRESENT”;
  • “WARNING – Potential Electrostatic Charging Hazard –Please wipe with a damp cloth when cleaning”;
  • End user shall use a certified cable gland suitable type of protection for final installation purpose;
  • External earthing wire shall be connected when used and the cross-sectional area shall be more than 4mm² or 10AWG;
  • Under rating conditions, the maximum temperature on the luminaire’s shell shall not be higher than 130℃ for T4. Temperature at cable inlet shall not be higher than allowable limit of the cable applied, to ensure the cable operation normally. For CES-EX-GB-02-30、CES-EX-GB-02-40,The branch point is 57.3℃ and the cable entry point is 52.3℃.

Features

  • Luminous flux: 3900lm / 5200lm
  • -40°C to +50°C ambient operating temperature
  • Wide optics for uniform illumination
  • 5 years warranty
  • Entry Size: M25*1.5
  • Housing – Aluminum alloy (ADC12)
  • Lens – tempered glass
  • Dimension: 200*157mm
  • Weight: 3KG

Parameters

  • Power: 30W / 40W
  • Input voltage: AC100-240/277V, 50/60Hz
  • Power factor: 0.97
  • Light efficacy: 120 - 140lm/W
  • CCT: 3000K/4000K/5000K/5700K/6500K
  • LEDs: 3030
  • LED Driver: Meanwell HBG series

Certificate & Standard

Certifications and compliances for hazardous location.

  • IECEx Certificate No. :  IECEx UL 22.0091X
    • Ex ec IIC T *Gc
    • Ex tb IIIC T *°C Db;
    • IP66;

  • ATEX Certificate No. :  UL 22 ATEX 2543X, UL 22 ATEX 2544X
    • II 3G Ex ec IIC T*Gc;
    • II 2D Ex tb IIIC T*Db;
    • IP66;

Mounting

Versatile mounting options:

  • Ceiling mount
  • Pole mount
 

Zone 21 Explosion Proof LED Light  - ATEX IECEx - 60W 80W

 

Applications

Wastewater treatment,oil and gas refineries, drilling rigs, petrochemical facilities, food and beverage facilities, tunnels, outdoor wall, and stanchion mounted general area lighting, and where flammable vapors, gases, ignitable dusts, fibers or flyings are present.

Standard :
ATEX: EN IEC 60079-0-2018; EN 60079-7-2015; EN 60079-31-2014;
IECEx: IEC 60079-0-2017; IEC 60079-7-2015; IEC 60079-31-2013;

Warning

IECEx& ATEX :

  • “WARNING – DO NOT OPEN WHEN ENERGIZED”;
  • “WARNING – DO NOT OPEN WHEN AN EXPLOSIVE ATMOSPHERE IS PRESENT”;
  • “WARNING – Potential Electrostatic Charging Hazard –Please wipe with a damp cloth when cleaning”;
  • End user shall use certified cable gland suitable type of protection for final installation purpose;
  • External earthing wire shall be connected when used and the cross-sectional area shall be more than 4mm² or 10AWG;
  • Under rating condition, maximum temperature on the luminaire’s shell shall not be higher than 130℃ for T4. Temperature at cable inlet shall not be higher than allowable limit of the cable applied, to ensure the cable operation normally. For CES-EX-GB-02-60、CES-EX-GB-02-80,The branch point is 58.2℃ and cable entry point is 52.6℃;

Features

  • Luminous flux: 7800lm / 10400lm
  • -40°C to +50°C ambient operating temperature
  • Wide optics for uniform illumination
  • 5 years warranty
  • Entry Size: M25 * 1.5
  • Housing – Aluminum alloy (ADC12)
  • Lens – tempered glass
  • Dimension: 300*204mm
  • Weight: 7KG

Parameters

  • Power: 60W / 80W
  • Input voltage: AC100-240/277V, 50/60Hz
  • Power factor: 0.97
  • Light efficacy: 120 - 140lm/W
  • CCT: 3000K/4000K/5000K/5700K/6500K
  • LEDs: 3030
  • LED Driver: Meanwell HBG series

Certificate & Standard

Certifications and compliances for hazardous location.

  • IECEx Certificate No. :  IECEx UL 22.0091X
    • Ex ec IIC T *Gc
    • Ex tb IIIC T *°C Db;
    • IP66;

  • ATEX Certificate No. :  UL 22 ATEX 2543X, UL 22 ATEX 2544X
    • II 3G Ex ec IIC T*Gc;
    • II 2D Ex tb IIIC T*Db;
    • IP66;

Mounting

Versatile mounting options:

  • Ceiling mount
  • Pole mount

CES-EX-LN-02P-E series 2ft length explosion proof class 1 division 2 exit sign with an backup Li-ion battery that provides 180 mins (3 hours) operation, output 1440 lumen flux.

This explosion proof led exit sign, can used for the hazard location of Class 1 Div 2 Groups A, B, C and D. For design and structure, it made of the die-cast aluminum and the PC cover. Good heat, and 6J impact resistance.

Remark: if you need IECEx and ATEx certified, please visit to 1ft / 2ft emergency epxlosion proof exit sign of Zone 1.

ATEX: EN IEC 60079-0-2018; EN 60079-7-2015; EN 60079-18-2015; EN 60079-31-2014;
IECEx: IEC 60079-0-2017; IEC 60079-7-2015; IEC 60079-18-2014; IEC 60079-31-2013;

  • CUL for Hazloc:

    • SUITABLE FOR WET LOCATIONS;
    • THIS LUMINAIRE IS ACCEPTABLE FOR OPERATION IN AMBIENT CONDITIONS NOT EXCEEDING __55__ °C (_131 °F);
    • MIN 90°C (194°F) SUPPLY CONDUCTORS;
    • NO SERVICEABLE PARTS” OR “NO USER SERVICEABLE PARTS. DO NOT OPEN FOR CLEANING.;
    • CAUTION - ″TO REDUCE THE RISK OF IGNITION OF HAZARDOUS ATMOSPHERES, DISCONNECT THE LUMINAIRE FROM THE SUPPLY CIRCUIT BEFORE OPENING. KEEP TIGHTLY CLOSED WHEN IN OPERATION.″;
    • THIS PRODUCT MUST BE INSTALLED IN ACCORDANCE WITH THE APPLICABLE INSTALLATION CODE BY A PERSON FAMILIAR WITH THE CONSTRUCTION AND OPERATION OF THE PRODUCT AND THE HAZARDS INVOLVED;
    • CAUTION – RISK OF SHOCK” and “DISCONNECT POWER BEFORE SERVICING”.

 

Features

  • Industry-leading efficacy: up to 120lm/W±5
  • -40°C to +45°C /50°C /55°CAmbient operating temperature
  • 5 years warranty
  • Entry Size: NPT 3/4”-14
  • Material : Aluminum alloy (ADC12 ) + PC

Parameters

  • Power (Normal lighting): 12W
  • Voltage: AC100-277V or DC24V
  • Power factor: 0.97
  • Lumen flux: 11440LM
  • CCT: 5500K (Optional)
  • LEDs: 3030 (6V)
  • LED Driver: High efficiency driver
  • Dimension: 629 mm x 125mm x 88.7 mm
  • Weight: 3.0KG
  • Emergency time: >= 3.0 hours (180 mins)

Certificate & Standard

Have certified CES-EX-LN-02P fixtures with the UL844 standards for hazardous location and environments.

NEC/CEC:

  • Class I, Division 2, Groups A, B, C and D
  • T-Class: T4A / T5
  • Damp and wet locations
  • Certify No:E475887

Standard:

  • US: UL 844; UL 1598;
  • Canada: CSA C22.2 No. 137; CSA C22.2 No. 250.0

 

Amounting

Versatile mounting options:

  • Wall Ceiling mounting

 

This 0.6 meters Explosion Proof emergency lighting is designed as the exit sign, it is available as an AC (100V - 277V) or DC 24V version, but it is available with a self-contained battery, no less than 90 min or 180 min backup for emergency use.

Features

  • Industry-leading efficacy: up to 120lm/W±5
  • -40°C to +45°C /50°C /55°CAmbient operating temperature
  • Wide optics for uniform illumination
  • 5 years warranty
  • Entry Size: M25Χ1.5 or NPT 3/4”-14
  • Material : Aluminum alloy (ADC12 ) + PC

Parameters

  • Power (Normal lighting): 20W / 30W / 40W/ 50W
  • Voltage: AC100-277V, 50/60Hz
  • Power factor: 0.97
  • Lumen flux: 2400LM / 3600LM / 4800LM / 6000LM
  • CCT: 2700K - 6500K (Optional)
  • LEDs: 3030 (6V)
  • LED Driver: High efficiency driver
  • Dimension: 629 mm x 125mm x 88.7 mm
  • Weight: 3.2KG (2 Foot)
  • Emegency function: Yes
  • Input voltage: DC24V
  • Emergency: >= 3.0 hours (180 mins)
  • Emergency power: 12W
  • Emergency lumen flux: 1440LM

Amounting

Versatile mounting options:

  • Wall Ceiling mounting

 

This Explosion Proof emergency lighting is designed as the exit sign, it is available as an AC (100V - 277V) or DC 24V version, but it is available with a self-contained battery, no less than 90 min or 180 min back up for emergency use.

Applications: In harsh and hazardous environments where illuminated exit signs are required.

 

Features

  • Industry-leading efficacy: up to 120lm/W±5
  • -40°C to +45°C /50°C /55°CAmbient operating temperature
  • Wide optics for uniform illumination
  • 5 years warranty
  • Entry Size: M25Χ1.5 or NPT 3/4”-14
  • Material : Aluminum alloy (ADC12 ) + PC

Parameters

  • Power: 5W
  • Voltage: AC100-277V, 50/60Hz
  •  Power factor: 0.97
  •  Lumen flux: 600LM
  •  CCT: 2700K - 6500K (Optional)
  •  LEDs: 3030 (6V)
  •  LED Driver: High efficiency driver
  •  Dimension: 329 mm x 125mm x 88.7 mm
  •  Weight: 2.5KG (1 Foot)
  • Emegency function: Yes
  • Input voltage: DC24V
  • Emergency: > 3.0 hours (180 mins)

 

Amounting

Versatile mounting options:

  • Wall Ceiling mounting