CES-EX-PL Series LED Hazardous Area LED Light Fixture is designed to provide a thin fixture profile that allows the maximum use of available space. This LED fixture is U.S. and Canada approved Class 1 Division 2, Groups A, B, C and D - Class II Division 2, Groups F and G and designed for paint spray booths and locations where flammable chemical/petrochemical/Workshop are present.

 

The CES-EX-PL Series LED Explosion Proof fixture is a 2 ft* 2ft, for use in paint spray booths and hazardous locations where space for lighting fixtures is limited. The lamp housing is only 1.57 inches thick, designed for recessed mounting. The chassis of housing adopts film coating technology, and provides operators in hazardous locations with a reliable and durable, low profile lighting solution.

 

Features

  • Power:24W / 36W / 48W
  • Input voltage: 120V~277V 50/60Hz
  • PF: 0.9
  • THD: <15%
  • Fliker: <5%
  • Dimming: 0-10V
  • Dimension:2ft*2ft / 603*603*40
  • Light efficacy: 120 lm/W
  • CCT: 3500-4000-5000 (Adjustable)
  • CRI:>80 Ra
  • Beam angle: >110°
  • UGR: 22
  • Lifespan:> 50000 hours
  • Certifications: UL, CE, Rohs, UL844 Ex-proof (Pending)

Certificate & Standard

Have certified CES-EX-PL fixtures with the North American UL844 standards for hazardous location and environments.

NEC/CEC:

  • Class I, Division 2, Groups A, B, C and D
  • Class I, Division 2, Groups E, F and G
  • Class II Division 2, Groups A, B, C and D
  • Class II Division 2, Groups E, F and G
  • T-Class: T4A / T5
  • Damp and wet locations
  • Certificate NO.: Pending

Standard:

  • US: UL 844; UL 1598;
  • Canada: CSA C22.2 No. 137; CSA C22.2 No. 250.0

 

Flexible and super toughening silica gel material, waterproof connector and Voltage IC Controller, Temperature IC Controller, so strip lighting designed especially for underground mines.

 

The CES-EX-S Series hazardous location LED strip light from CESP is designed to provide a high output and ruggedly durable lighting solution for applications where Class 1 Division 2, Groups A, B, C and D compliance is required. This powerful LED strip light produces Luminous Efficacy 80 LM/ W, operates from AC 100 to 240V, or you can choose AC to DC convertors, miniature voltage convertors, it is suitable for a variety of applications. Flexible, good sealing, up to IP67 rating, providing limited ingress protection against dust, and basic protection against splashing water. This strip light is weather resistant, suitable for indoor and outdoor applications, and ideal for areas where wetness or dusty conditions are commonly encountered.

 

Installation:

Mounting for this LED strip light is provided by two adjustable end brackets that allow the operators to mount the light to flat surfaces, side or 90°cable entry size. This hazardous location strip light is ideal for areas where space is limited, this hazardous location LED strip light is completed with an optional explosion proof cord cap, very easy connection to corresponding explosion proof outlets.  it provide complete protection when used in a Class 1 Division 2 area.

 

“ Spectroscopic controlled by BRT

Ensuring customers to get the same color even from different orders by

strictly management to the LED color tolerance. “

 

Features

  • Industry-leading efficacy: up to 105 - 110lm/W
  • LED Type: 2835
  • LED Quantity: 168 LEDs
  • Power: 15W/meter, 18W/meter
  • Input voltage: AC100-240V / DC 12V / DC 24V
  • Color: Cool white / Warm white / RGB (Can be customized)
  • CCT: 2700K, 3000K, 3500K, 4000K, 5000K, 6000K
  • CRI: >80 Ra
  • Protection grade: IP65 / IP 67
  • Material: Environmentally friendly silicone materia
  • Environment: anti-explosive, anti-corrosion, flame retardant resistance, UV resistance
  • Beam angle:120°

Certificate & Standard

Have certified CES-EX-S fixtures with the North American UL844 standards for hazardous location and environments.

NEC/CEC:

  • Class I, Division 2, Groups A, B, C and D
  • Class I, Division 2, Groups E, F and G
  • Class II Division 2, Groups A, B, C and D
  • Class II Division 2, Groups E, F and G
  • T-Class: T4A / T5
  • Damp and wet locations

Standard:

  • US: UL 844; UL 1598;
  • Canada: CSA C22.2 No. 137; CSA C22.2 No. 250.0

 

This Drop Light is 360 beam angle, comes complete with 10 meters (according to your requirement can be more longer) of explosion proof cord and an inline transformer that steps down 220V AC to 24V AC or DC for powering the lamp. The hand lamp is designed to provide an effective low voltage lighting solution for operators requiring a versatile source of illumination.

10W, 20W, 30W power optional, ideal for general work task lighting in hazardous locations requiring explosion proof protection.

 

*PLEASE NOTE: THE TRANSFORMER MUST BE LOCATED OUTSIDE THE HAZARDOUS LOCATION*

Contact us ask for detail Layout Diagram will be more clear: This email address is being protected from spambots. You need JavaScript enabled to view it.

 

Features

  • Industry-leading efficacy: up to 130lm/W±5
  • -40°C to +50°CCAmbient operating temperature
  • Swivel hook for hanging and hands free operation
  • Prevent drop damage
  • 5 years warranty
  • Housing –Aluminum alloy (ADC12 )
  • Lens – tempered glass (10mm)
  • Beam angle:360°

Parameters

  • Power: 10W / 20W / 30W
  •  Input voltage AC100V-277V; Frequency: 50/60Hz;
  • Output voltage: DC24V;
  • Lumen flux: 1300LM/2600LM/3900LM
  • CCT: 6500K (Optional)
  • LEDs: 3030
  • Beam angle: 180°
  • LED Driver: High Efficiency LED Driver
  • Entry Size: M20X1.5
  • Dimension: Φ101.5 x 516.5 mm
  • Weight: 2.4KG

 

This Flameproof Hand Lamp / Drop Light is 180 beam angle, comes complete with 10 meters (according to your requirement can be more longer) of explosion proof cord and an inline transformer that steps down 220V AC to 24V AC or DC for powering the lamp. The hand lamp is designed to provide an effective low voltage lighting solution for operators requiring a versatile source of illumination.

This hazardous location hand lamp is 10W, 20W, 30W power optional, ATEX IECEx Listed Zone 1 & 21, Zone 2 & 22, is ideal for general work task lighting in hazardous locations requiring explosion proof protection.

*PLEASE NOTE: THE TRANSFORMER MUST BE LOCATED OUTSIDE THE HAZARDOUS LOCATION*

Contact us ask for detail Layout Diagram will be more clear: This email address is being protected from spambots. You need JavaScript enabled to view it.

 

Warning:

IECEx & ATEX:

  • “WARNING – DO NOT OPEN WHEN ENERGIZED”
  • “WARNING – DO NOT OPEN WHEN AN EXPLOSIVE ATMOSPHERE IS PRESENT”
  • “WARNING – POTENTIAL ELECTROSTATIC CHARGING HAZARD - SEE INSTRUCTIONS”
  • THE FLAMEPROOF JOINTS ARE NOT INTENDED TO BE REPAIRED.
  • End user shall use certified cable gland type of protection for final installation purpose.
  • Under rating condition, maximum temperature on the luminaire’s shell shall not be higher than 80℃for T6.Temperature at cable inlet shall not be higher than allowable limit of the cable applied, to ensure the cable operation normally. The branch point is60.1℃ and cable entry point is 52.℃.
  • For handle, there is “POTENTIAL ELECTROSTATIC CHARGING HAZARD”. When used in the explosive environment, please touch with an insulating object, wipe with a damp cloth.

 

Features

  • Industry-leading efficacy: up to 130lm/W±5
  • -40°C to +50°CCAmbient operating temperature
  • Swivel hook for hanging and hands free operation
  • Prevent drop damage
  • 5 years warranty
  • Housing –Aluminum alloy (ADC12 )
  • Lens – tempered glass (10mm)
  • Beam angle:360°

Parameters

  • Power: 10W / 20W / 30W
  •  Input voltage AC100V-277V; Frequency: 50/60Hz;
  • Output voltage: DC24V;
  • Lumen flux: 1300LM/2600LM/3900LM
  • CCT: 6500K (Optional)
  • LEDs: 3030
  • Beam angle: 180°
  • LED Driver: High Efficiency LED Driver
  • Entry Size: M20X1.5
  • Dimension: Φ101.5 x 516.5 mm
  • Weight: 2.4KG

Certificate & Standard

Have certified CES-EX-SC with the IECEX and ATEX standards for hazardous location and environments.

ATEX:
  • II 2G Ex db eb IIC T6 Gb
  • II 2D Ex tb IIIC T 80°C Db
  • Certify No.:SEV 20 ATEX 0369 X
IECEx:
  • Ex db eb IIC T6 Gb
  • Ex tb IIIC T 80°C Db
  • Certify No.:IECEx SEV 20.0003X

CES-EX-SC Series flameproof hand lamp with an inline transformer is a type of portable lighting device that is designed for use in hazardous or explosive environments, such as in mining, oil and gas, and chemical processing industries. The flameproof construction of the hand lamp is designed to prevent the ignition of explosive gases, vapors, or dust that may be present in the environment.

The inline transformer is a separate component that is designed to convert the high voltage electrical supply to a lower voltage suitable for powering the hand lamp (220V AC to 24V AC or DC) to provide an effective low voltage lighting solution for operators requiring a versatile source of illumination.. The transformer is typically placed in-line with the electrical cable that connects the hand lamp to the power source.

The hand lamp itself typically has a rugged construction with a protective cage or guard around the bulb to prevent damage from impacts or falls. The lamp may be powered by a variety of sources, including batteries or a direct electrical connection to a power source.

The series of hazardous location hand lamp is 10W, 20W, 30W power optional, ATEX IECEx Listed Zone 1 & 21, Zone 2 & 22, is ideal for general work task lighting in hazardous locations requiring explosion proof protection.

*PLEASE NOTE: THE TRANSFORMER MUST BE LOCATED OUTSIDE THE HAZARDOUS LOCATION*

Contact us ask for detail Layout Diagram will be more clear: This email address is being protected from spambots. You need JavaScript enabled to view it.

 

Warning:

IECEx & ATEX:

  • “WARNING – DO NOT OPEN WHEN ENERGIZED”
  • “WARNING – DO NOT OPEN WHEN AN EXPLOSIVE ATMOSPHERE IS PRESENT”
  • “WARNING – POTENTIAL ELECTROSTATIC CHARGING HAZARD - SEE INSTRUCTIONS”
  • THE FLAMEPROOF JOINTS ARE NOT INTENDED TO BE REPAIRED.
  • End user shall use certified cable gland type of protection for final installation purpose.
  • Under rating condition, maximum temperature on the luminaire’s shell shall not be higher than 80℃for T6.Temperature at cable inlet shall not be higher than allowable limit of the cable applied, to ensure the cable operation normally. The branch point is60.1℃ and cable entry point is 52.℃.
  • For handle, there is “POTENTIAL ELECTROSTATIC CHARGING HAZARD”. When used in the explosive environment, please touch with an insulating object, wipe with a damp cloth.

 

Features

  • Industry-leading efficacy: up to 130lm/W±5
  • -40°C to +50°CCAmbient operating temperature
  • Swivel hook for hanging and hands free operation
  • Prevent drop damage
  • 5 years warranty
  • Housing –Aluminum alloy (ADC12 )
  • Lens – tempered glass (10mm)
  • Beam angle:360°

Parameters

  • Power: 10W / 20W / 30W
  •  Input voltage AC100V-277V; Frequency: 50/60Hz;
  • Output voltage: DC24V;
  • Lumen flux: 1300LM/2600LM/3900LM
  • CCT: 6500K (Optional)
  • LEDs: 3030
  • LED Driver: High Efficiency LED Driver
  • Entry Size: M20X1.5
  • Dimension: Φ101.5 x 516.5 mm
  • Weight: 2.4KG

Certificate & Standard

Have certified CES-EX-SC with the IECEX and ATEX standards for hazardous location and environments.

ATEX:
  • II 2G Ex db eb IIC T6 Gb
  • II 2D Ex tb IIIC T 80°C Db
  • Certify No.:SEV 20 ATEX 0369 X
IECEx:
  • Ex db eb IIC T6 Gb
  • Ex tb IIIC T 80°C Db
  • Certify No.:IECEx SEV 20.0003X

The CES-SC explosion-proof hand lamp is designed for use in hazardous environments where the presence of flammable gases, vapors, or dust particles may pose a risk of explosion. It is made of high-quality materials to ensure durability and safety, and is suitable for use in Class 1 Division 1 hazardous areas.

The body of the hand lamp is made of ADC12 aluminum alloy, which is a lightweight and strong material that can withstand high temperatures and impacts. The lamp is also fitted with a 10mm high-strength tempered glass lens (frosted, no glare), which provides excellent visibility while also protecting the bulb from damage.

To ensure safe operation, the hand lamp is equipped with an inline transformer and 10 or 50 meters (according to your requirement can be more longer) that steps down 120V AC to 24V AC or DC for powering the lamp. The hand lamp is designed to provide an effective low voltage lighting solution for operators requiring a versatile source of illumination.

In addition to its safety features, the explosion-proof hand lamp is also easy to carry and transport. Its compact size and lightweight design make it ideal for use in a variety of settings, from industrial sites to construction sites and inspection ,ect.

Overall, the explosion-proof hand lamp is a reliable and effective lighting solution for hazardous environments. Its high-quality construction, safety features, and portability make it an essential tool for anyone working in hazardous areas.

 

CUL for Hazloc:

  • SUITABLE FOR WET LOCATIONS;
  • THIS LUMINAIRE IS ACCEPTABLE FOR OPERATION IN AMBIENT CONDITIONS NOT EXCEEDING __55__ °C (_131 °F);
  • MIN 90°C (194°F) SUPPLY CONDUCTORS;
  • NO SERVICEABLE PARTS” OR “NO USER SERVICEABLE PARTS. DO NOT OPEN FOR CLEANING.;
  • CAUTION - ″TO REDUCE THE RISK OF IGNITION OF HAZARDOUS ATMOSPHERES, DISCONNECT THE LUMINAIRE FROM THE SUPPLY CIRCUIT BEFORE OPENING. KEEP TIGHTLY CLOSED WHEN IN OPERATION.″;
  • THIS PRODUCT MUST BE INSTALLED IN ACCORDANCE WITH THE APPLICABLE INSTALLATION CODE BY A PERSON FAMILIAR WITH THE CONSTRUCTION AND OPERATION OF THE PRODUCT AND THE HAZARDS INVOLVED;
  • CAUTION – RISK OF SHOCK” and “DISCONNECT POWER BEFORE SERVICING”.

Features

  • Industry-leading efficacy: up to 130lm/W±5
  • -40°C to +50°CCAmbient operating temperature
  • Swivel hook for hanging and hands free operation
  • Prevent drop damage
  • 5 years warranty
  • Housing –Aluminum alloy (ADC12 )
  • Lens – tempered glass (10mm)
  • Beam angle:360°

Parameters

  •  Power: 10W / 20W / 30W
  •  Input voltage: 100-240Vac; Frequency: 50/60Hz;
  • Output voltage: 24Vdc
  •  Lumen flux: 1300LM/2600LM/3900LM
  •  CCT: 6500K (Optional)
  •  LEDs: 3030
  •  LED Driver: High Efficiency LED Driver
  •  Dimension: Φ101.5 x 516.5 mm
  •  Weight: 2.4KG

Certificate & Standard

Have certified CES-SC fixtures with the North American UL844 standards for hazardous location and environments.

NEC/CEC:

  • Class I, Division 2, Groups A, B, C and D
  • Class II, Division 1, Groups E, F and G
  • Class I, Division 2, Groups A, B, C and D
  • Class II, Division 2, Groups F and G
  • Class III
  • T-Class: T6 / T80°C
  • Damp and wet locations
  • Paint spray rated
  • Certificate No:E475887

 

Standard:

  • US: UL 844; UL 153;
  • Canada: CSA C22.2 No. 137; CSA C22.2 No.250.4

 

  • Adpot to LEDs green-technology, energey saving, long lifespan.
  • The housing is made of high-quality die-cast aluminum with anti-corrosion powder, which is corrosion-resistant and wear-resistant.
  • It is suitable for indoors and outdoors where flammable gases or vapors or combustible dusts exist and create a hazardous locations and so on.
  • Easy installation: Simplify the installation process, eliminate complex links, and make the installation project more convenient.
  • AC100-277V 100-277V input voltage

Features

  • Industry-leading efficacy: up to 120lm/W±5
  • -40°C to +45°C / 50°C / 55°CAmbient operating temperature
  • Wide optics for uniform illumination
  • 5 years warranty
  • Entry Size: M25Χ1.5 or NPT 3/4”-14
  • Housing –Aluminum alloy (ADC12)

Parameters

  • Power: 5 Watt
  •  Input voltage: AC100-277V, 50/60Hz
  •  Power factor: 0.97
  •  Lumen flux: 600lm
  •  CCT: 620-720K, Warm White
  • Lamp type: LED (Bridgelux 3030 )
  •  LED Driver: High efficiency driver
  • Emergency time: more than 90 min (1.5 hours)

Standard

Have certified CES-EX-BS-02 fixtures with with the North American UL844 standards for hazardous location and environments.

  • Class I, Division 1 Groups C&D
  • Class I, Division 2 Groups A,B,C,D
  • Class II, Division 1 Groups E,F,G
  • Class II, Division 2 Groups F&G
  • Class III, Divisions 1 & 2
  • Designed to UL 1598A, UL 844
  • Suitable for Marine Use
  • T6 Temperature Rating

 

Amounting

Versatile mounting options:

  • Customized

     

CES-EX-BS-02 Explosion Proof LED exit signs are designed for hazardous locations and are ideally suited for marking escape routes and exits in potentially explosive gas atmospheres or explosive dust atmospheres. This emergency LED Exit sign is available as an AC (100V - 270V) only version, but it is available with self-contained battery, no less than 90 min back up for emergency use.

Applications: In harsh and hazardous environments where illuminated exit signs are required.

 explosion proof exit signs

Features:

  • UL1598, 844, 924. IP 65, marine outside type
  • Die-cast aluminum housing with anti-corrosion powder
  • Long life (>50000 hours) for years of maintenance-free operation
  • Energy-efficient for lower cost of operation
  • Low temperature operation with no loss of illumination
  • Rugged and durable light source for the harshest of environments

Features

  • Industry-leading efficacy: up to 120lm/W±5
  • -40°C to +45°C / 50°C / 55°CAmbient operating temperature
  • Wide optics for uniform illumination
  • 5 years warranty
  • Entry Size: M25Χ1.5 or NPT 3/4”-14
  • Housing –Aluminum alloy (ADC12)

Parameters

  • Power: 5 Watt
  •  Input voltage: AC100-277V, 50/60Hz
  •  Power factor: 0.97
  •  Lumen flux: 600lm
  •  CCT: 620-720K, Warm White
  • Lamp type: LED (Bridgelux 3030 )
  •  LED Driver: High efficiency driver
  • Emergency time: more than 90 min (1.5 hours)

Standard

Have certified CES-EX-BS-02 fixtures with with the North American UL844 standards for hazardous location and environments.

  • Class I, Division 1 Groups C&D
  • Class I, Division 2 Groups A,B,C,D
  • Class II, Division 1 Groups E,F,G
  • Class II, Division 2 Groups F&G
  • Class III, Divisions 1 & 2
  • Designed to UL 1598A, UL 844
  • Suitable for Marine Use
  • T6 Temperature Rating

 

Amounting

Versatile mounting options:

  • Wall Mount

     

Description:

CES-EX-BS5 Led explosion proof emergency exit sign light is 5 Watt, has back up emergency ballast, it uses normal extermal power to iluminate 5 Watt led under normal conditions. In any situation where power is interrupted, I'll automatically switches to a battery backup model which will power for 90min or until power is restored. It rated for Class 1 Division 1&2, Class II Division 1&2, and is an ideal emergency exit marking solution for hazardous locations where fail safe reliability is a must.

Features

  • Industry-leading efficacy: up to 120lm/W±5
  • -40°C to +45°C /50°C /55°CAmbient operating temperature
  • Wide optics for uniform illumination
  • 5 years warranty
  • Entry Size: M25Χ1.5 or NPT 3/4”-14
  • Housing –Aluminum alloy (ADC12)

Parameters

  • Power: 5 Watt
  •  Input voltage: AC100-277V, 50/60Hz
  •  Power factor: 0.97
  •  Lumen flux: 600lm/W
  •  CCT: 620-720K, Warm White
  • Lamp type: LED (Bridgelux 3030 )
  •  LED Driver: High efficiency driver
  • Emergency time: more than 90 min (1.5 hours)

Standard

Have certified CES-EX-BS fixtures with with the North American UL844 standards for hazardous location and environments.

  • Class I, Division 1 Groups C&D
  • Class I, Division 2 Groups A,B,C,D
  • Class II, Division 1 Groups E,F,G
  • Class II, Division 2 Groups F&G
  • Class III, Divisions 1 & 2
  • Designed to UL 1598A, UL 844
  • Suitable for Marine Use
  • T6 Temperature Rating

 

Amounting

Versatile mounting options:

  • Wall Mount / Pendant Ceiling Mount

     

Saturday, 09 April 2022 07:40

Overview of ATEx and IECEx Certification

Equipment products certified by ATEX or IECEx are essential to be put into use in any potentially explosive or potentially explosive environments, and are an important guarantee to help create production safety. Most of us have heard of ATEX and IECEx certification, but many people sometimes still don't know the relationship between them. Let's introduce the relationship between the two certifications in detail.

IECEx explosion proof certification

International Electrotechnical Commission explosion-proof electrical product certification system (IEC Scheme for Certification to Standards for Electrical Equipment for Explosive atmospheres, hereinafter referred to as IECEx  certification system) was established in 1996, is an international explosion-proof electrical product certification organization. Member countries of IECEx certification system include Australia, Canada, China, Denmark, Finland, France, Germany, Hungary, Italy, Japan, South Korea, Netherlands, Norway, New Zealand, Singapore, Romania, Serbia and Montenegro (formerly Yugoslavia), Russia, Slovenia , South Africa, Sweden, Switzerland, the United Kingdom and the United States 24, and are still increasing.

The goal of the IECEx system is to accept a standard worldwide ---- IEC/TC31 series of standards for electrical equipment for explosive hazardous environments; a certificate ---- IECEx certification certificate (IECEx Certification of Conformity); a mark -- -- IECEx certification mark (IECEx Mark of Conformity).

However, the explosion-proof products currently exported to EU countries only recognize the ATEX certificate, not the IECEx certificate. Some of the benefits of choosing a product with IECEx certification include:

(1) Increase market competitiveness. Products that have passed IECEx certification show that they have passed a series of tests of IEC60079 related standards and have reliable safety.

(2) Expand market circulation. At present, there are more than 50 member states of the IECEx system. Products used for IECEx certification can enter the market faster in these member states and shorten the time to market.

IECEx control products and main standards

The scope of IECEx controlled products is: pure electrical products/equipment used in explosion-proof environment, non-electrical products/equipment;

IECEx main standard: According to the difference in explosion-proof design of different equipment, it needs to be judged by professional and technical personnel. You can contact Eurotest for inquiries.

 

IECEx Certificate Overview

The IECEx certification system includes IECEx 02 product certification, IECEx 03 service certification, IECEx04 logo license, and IECEx05 personnel competency certification as shown in Figure as bellow,

IECEx System

IECEx Certificate System Component

 

IECEx Certificate System Component

 

IECEx02 product certification stipulates that all explosion-proof products must meet the certification requirements. The certification process includes the applicant submitting the certification application, Ex TL conducting the explosion-proof type test, Ex CB conducting on-site inspection of the manufacturer's quality system, and Ex CB making the certification decision (issuing Ex TR and QAR), Ex CB issues the IECEx certification certificate, publishes it on the IECEx website, and Ex CB supervises the certified enterprise. Product certification is carried out in accordance with IECx OD003, IECEx OD009, IECEx OD017 and operation documents, and needs to meet the requirements of IEC 60079 series of technical standards. The quality system review of the manufacturer is carried out according to IEC OD005 operation documents. The simplified flow of certification procedures is shown in Figure

IECEx Certificate

IECEx Certificate Flow Chart

 

IECEx03 service certification includes the audit of maintenance facilities, equipment and systems, confirmation of personnel's ability, and finally the generation of IECEx service certification. In order to meet the needs of the use department of Ex products for the quality certification of explosion-proof equipment repair and overhaul, the IECEx system began to launch IECEx service certification on the basis of explosion-proof product certification in 2003, including the factory or workshop certification plan for explosion-proof equipment repair and overhaul . In this regard, manufacturers of explosion-proof products can apply for IECEx service or choose to use manufacturers with IECEx system service certification.

The advantages of an explosion-proof product manufacturer applying for IECEx service include: it can prove the manufacturer's ability to repair explosion-proof products; if an explosion or fire occurs, it can resist liability lawsuits against the manufacturer for the repaired electrical equipment; it can ensure that explosion-proof products are in use consistency; enhances end-user confidence in purchasing products from explosion-proof product manufacturers. IECEx03 service certification is based on IECEx OD014 operation document, which puts forward specific requirements for the quality system, technical documents, facilities and equipment, and personnel of explosion-proof equipment repair factories; IECEx OD 013 operation document makes specific provisions for the review of Ex service certification; IEC60079 -19 made detailed requirements for specific content.

IECEx05 personnel competency certification provides proof that the knowledge and skills of personnel engaged in explosion-proof equipment and related personnel in explosive environments meet IECEx requirements, whether they have mastered safe operating procedures in hazardous locations, and whether they can correctly install, inspect, maintain and repair explosion-proof equipment and systems. . IECEx personnel competency assessment is carried out according to IECEx OD501, IECEx OD502, IECEx OD503, IECEx OD504 operation documents. The specific competency units are shown in Table 1. Each unit has clear requirements for personnel experience, knowledge and skills. Applicants need to have certain skills. Only after technical experience and training experience can you apply for evaluation. Unit 001 is the basic unit, and the unit must be based on 001 to apply for the evaluation of other units.

Table 1 Personnel competency certification components

No.

Competency components

1

Basic guidelines for applying explosion protection

2

Zoning of hazardous locations

3

Installation of explosion-proof equipment and wiring systems

4

Maintenance of Explosive Atmosphere Equipment

5

Overhaul and repair of explosion-proof equipment

6

Testing of electrical installations related to explosive atmospheres

7

Visual and general inspection of electrical installations in explosive atmospheres

8

Detailed inspection of electrical installations in explosive atmospheres

9

Design of Electrical Installations for Explosive Atmospheres

10

Inspection of electrical installations in explosive atmospheres

 

IECEx certification conducts international certification for explosion-proof electrical products in accordance with international standards, which can reduce the manufacturer's certification costs and time to enter the market on the premise of ensuring the appropriate safety level of explosion-proof electrical products, and maintain international standards in the process of product and service evaluation. And the service evaluation is included in an international database, which increases the user's trust in the manufacturer's or personnel's service, and has received extensive support from the industry and related parties in various countries.

Three main steps to obtain IECEx-COC explosion-proof certificate

- Obtaining IECEx-TR files;

- The factory has obtained the IECEx-QA explosion-proof system certificate;

- Register and record on IECEX official website to form IECEx-COC certificate. 

 

Main classification of IECEx certificate

- Batch unit certification, that is, the IECEx certificate is only valid for this batch of products;

- COC type certification, that is, a specific type of product with a certain explosion-proof design meets the requirements of IECEx, and can be used for a long time under the condition that the IECEx system certificate is always valid;

- The IECEx explosion-proof system certificate is the QA certificate, which indicates that the certificate holder has the ability to control products that meet the requirements of the corresponding IECEx explosion-proof standards.

 

ATEX explosion-proof certification

The ATEX directive in CE certification is 2014/34/EU (the old directive 94/9/EC). ATEX is derived from the French "Atmosphere EXlposible". On March 23, 1994, the European Commission adopted "equipment and protection for potentially explosive environments. System" (94/9/EC) Directive. The Directive has been in use since 1996 and has been enforced since July 1, 2003.​​

This directive covers mine and non-mine equipment. Unlike previous directives, it includes mechanical equipment and electrical equipment, and extends the potentially explosive atmosphere to dust and flammable gases, flammable vapors and mists in the air. This directive is the "new approach" directive commonly referred to as ATEX 100A, the current ATEX explosion protection directive.​​

Manufacturers of equipment intended for use in potentially explosive atmospheres, applying the terms of the ATEX directive and affixing the CE mark, can sell their explosion-proof equipment anywhere in Europe without considering the application of additional requirements.

ATEX explosion-proof certification is a mandatory requirement for explosion-proof products to enter the EU market. Therefore, products used for explosive products entering the EU market must follow the ATEX directive, obtain ATEX certification, and affix the ATEX mark on the product.

Explosion-proof group classification

Mining Group I

Mining Group I

Non-mining Group II

Non-mining Group II

 

Classification of explosion-proof areas

Zone 0 (Gas)

Areas where explosive atmospheres persist or occur frequently

Zone 1 (Gas)

When the equipment is in normal operation, the explosive environment exists or may exist for a long time, and the frequency is occasional

Zone 2 (Gas)

When the equipment is not operating normally, the explosive environment exists or may exist for a short period of time, and the frequency under normal circumstances is less likely to occur

Zone 20 (dust)

More than 1000 hours/year or more than 10%/cycle

Zone 21 (dust)

10~1000 hours/year or 0.1~10%/cycle

Zone 22 (dust)

Less than 10 hours/year or less than 0.1%/cycle

 

Explosion-proof categories, zones and markings

 

ATEX

Standard

EN60079

 

Group

Areas

Ex-Proof Marking

Coal Mine

I

Category M1( I M 1 )

Ex ia I

Ex Ib I

Ex d I

Category M2( I M 2 )

Manufacturer's certificate

Gas-Ex

II

Zone 0 ( II 1 G )

Ex ia II C/B/A

Ex s

Zone 1 ( II 2 G )

EEx ia II C/B/A

EEx s

EEx ib II C/B/A

EEx d II C/B/A

EEx e

EEx px, py

EEx o

EEx q

EEx m

EEx s

 

Zone 2 ( II 3 G )

Suitable for all types of zones 0 and 1

EEx nA

EEx nC

EEx nL

EEx nR

EEx pz

 

Standard

EN50281

Dust-Ex

III

Zone 20 ( II 1 D )

Ex 1D

Zone 21 ( II 2 D )

Ex 2D

Zone 22 ( II 3 D )

Ex 3D

 

Explosive Hazardous Gas Classification

Group

ATEX

Typical gas

Ignition characteristics

I

I

Methane

From easy to difficult

II

II A

propane

II B

vinyl

II C

hydrogen

Acetylene

 

T-Class Classification

Temperature

Classification

safe surface temperature

Common Explosive Gases

T1

Less than or equal to 450 ℃

46 kinds of hydrogen, acrylonitrile, etc.

T2

Less than or equal to 300 ℃

47 kinds of acetylene, ethylene, etc.

T3

Less than or equal to 200 ℃

36 kinds of gasoline, crotonaldehyde, etc.

T4

Less than or equal to 135 ℃

6 kinds of acetaldehyde, tetrafluoroethylene, etc.

T5

less than or equal to 100 ℃

carbon disulfide

T6

less than or equal to 85 ℃

Ethyl nitrate and ethyl nitrite

 

Introduction of common explosion-proof methods

Explosion-proof way

EN Standard

Description of explosion-proof method

Ex d - Flameproof

EN 60079-1

When the equipment is in normal operation, the components that can generate the detonation source are put into the explosion-proof enclosure. The explosion-proof enclosure can withstand the internal explosion pressure without loss, and can effectively prevent the explosion from spreading to the outside of the enclosure.

Ex e - Increased Safety

EN 60079-7

Through the design of the product, the detonation source that can generate hot surface or arc or spark can be eliminated, so as to achieve the purpose of explosion protection.

Ex i - Intrinsically Safe

EN 60079-11

Circuit energy is limited by related techniques so that sparks or hot surfaces from electrical energy in electrical equipment are not sufficient to detonate substances in explosive atmospheres.

Ex m - Encapsulation

EN 60079-18

The equipment or its part that may ignite the substances in the explosive atmosphere is sealed in a substance, and the equipment or its part is isolated from the substances in the explosive atmosphere, so as to achieve the purpose of explosion protection.

Ex n - non-sparking

EN 60079-15

The magic seal is used to prevent the flammable substances in the explosive environment from contacting the sparks or arcs generated by the equipment, and at the same time eliminate the hot surface generated by the equipment, so as to achieve the purpose of explosion-proof.

Ex p - Pressurized Enclosure

EN 60079-2

The equipment or components that will generate the detonation source are prevented from being contained in an enclosure. The enclosure is first filled with an inert gas to remove the flammable substances in it, and at the same time, by maintaining the pressure inside the enclosure, the entry of external flammable substances is prevented, thereby preventing the entry of flammable substances. To achieve the purpose of explosion-proof.

Ex o - Oil Immersion

EN 60079-6

Submerge the entire components of electrical equipment in a protective liquid so that substances in the explosive atmosphere cannot contact the hot surfaces or sparks of the equipment.

Ex q - Powder Filling

EN 60079-5

Bury the components of electrical equipment in sand so that substances in the explosive atmosphere cannot relieve hot surfaces or sparks of the equipment.

 

ATEX Explosion-proof Markingfor reference only

ATEX certificate

 

The main difference between ATEX certification and IECEx certification

Although both ATEX certification and IECEx certification describe the necessary requirements for equipment used in potentially hazardous and hazardous locations, they differ in some respects, the main difference being that ATEX certification is driven by laws and IECEx certification is driven by standards.

Another difference is that ATEX certification is only valid in the EU, while IECEx certification is accepted worldwide. Likewise, ATEX certification is required by law for all non-electrical and electrical equipment to be used in hazardous locations. However, IECEx certification is only required for electrical equipment in hazardous locations.

In terms of standards, it is not mandatory for ATEX certification to conform to the standard, but for IECEx certification, a third-party certification body is responsible for combining all aspects of manufacturing and design for public certification. In short, IECEx certification is stricter than ATEX certification in the handling of evidence during the certification process.

Another fundamental difference is how each guide is set up. The IECEx certification system is actually one of the four conformity assessment systems operated by the IEC. The IECEx certification system consists of four independent international certification parts, including the IECEx Certified Equipment Program, the IECEx Certified Service Program, the IECEx Certified Conformity Mark Licensing System and the IECEx Certified Qualified Persons Program. However, ATEX certification refers to two separate but related directives, as described above.

 

The following list illustrates the relationship

Content

ATEX

IECEx

Scope of application

European

IECEx member countries (except North American countries)

Is it mandatory

Mandatory

Non-Mandatory

Executive standard

IEC60079

IEC60079

Explosion-proof mark

ATEX Logo 

Printed Ex logo

convert

At present, ATEX certificates cannot be converted into certificates from other countries outside the EU

IEC member countries (except North American countries) recognize the IECEx report, which can be directly converted into the explosion-proof certification of the local country, except that some countries need to do some local difference tests.