IECEx ATEX Certified Explosion proof LED Lights - Zone 1 Zone 2 Hazardous Area Lighting

CESP Zone 1 Zone 2 hazardous location LED lights are in accordance with International Protection Techniques (Equipment Protection Levels), including IEC/EN 60079-0 (General Requirement), IEC/EN 60079-1 (Flameproof Enclosure), IEC/EN 60079-7 (Increased Safety), IEC/EN 60079-11 (Intrinsic Safety), IEC/EN 60079-15 (Type of Protection), IEC/EN 60079-18, IEC/EN 60079-28, IEC/EN 60079-31. If you are not sure about the Classified of your lighting application environment, please contact our technical department for the solution.
 

For Zone 1 Zone 2, Zone 21 Zone 22 hazardous area led lighting, 20W - 200W, 130lm/W,aluminum alloy + 8mm tempered glass, multi-installation for different projects, such as light tower, canopy light, marine grade.

Flameproof enclosure, Ex db op is IIC T6 Gb, Zone 1 & Zone 21 with explosive gas atmosphere, Zone 21 and Zone22 with explosive dust atmosphere, 10mm temered glass, 7J impact resistance,up to 26000lm.

Flameproof enclosure, Ex db op is IIC T6 Gb, IP68 protection grade, tempered glass 10mm, withstand impacts up to 10J, 2 foot and 4 foot Length, 50Watt- 240Watt, 130lm/W light efficacy.

Zone 1 & Zone 21, 1ft, 2ft, 3ft, 4ft length can be selected, replace the traditional explosion-proof three-proof lamp, explosion-proof fluorescent tube, anti-corrosion, anti-glare, anti-drop, competitive price.

Flameproof LED hand lamp for Zone 1 & Zone 21 hazardous areas, 10mm tempered glass, pass the multi-angle drop test, 10W, 20W, 30W Power, can be connected to the cable, emergency power box.

The CES-EX-SF series explosion-proof ceiling lamp has a strong shell, with features such as impact resistance, vibration resistance, and corrosion resistance. It can be used in hazardous environments of Zone 1&21, Zone 2&22.

CES-EX-JX Series is your go-to solution for illuminating hazardous Zone 1 and Zone 21 areas. With ATEX approval, these Explosion-proof LED Flood Lights offer unbeatable safety standards.

Discover the pinnacle of safety and illumination with our CES-EX-GBX Series Explosion-proof LED High Bay Lights. Designed for hazardous Zone 1 and Zone 21 areas, these lights boast ATEX approval, ensuring the highest safety standards.

GB-02 explosion-proof lights are made of alloy aluminum and tempered glass, with shock resistance and anti-vibration performance. The luminaires have passed the ATEX IECEx standards test, from 30W to 80W for hazardous area lighting.

LN-02 explosion-proof lights obtained an IECEx ATEX certificate, it's safe for the Zone 1 and Zone 2 hazardous locations. The copper-free aluminum alloy body is powder-coated to increase durability and beautiful appearance, are able to withstand violent shaking and shock resistance.

an innovative line of LED hazardous area lighting products, specifically designed for use in potentially explosive atmospheres (Zone 1/21 & 2/22) within harsh industrial settings such as coal mines and oil & gas facilities.

Explosion-proof safety exit lamps are for personnel evacuation, and fire operations to provide lighting fire emergency lamps! It usually uses an external power supply, when the power automatically switches to the battery power state!

 
Super User

Super User

Big fan of opensource and ubuntu

Website URL: http://joomlabuff.com/

IECEx ATEX Certified, Zone 1, Ex db op is IIC T5/T6 Gb, Zone 21, Ex tb op is IIC T94°C/T89°C/T84°C - 120W 150W 185W 200W 240W

 

Applications:

• Wastewater treatment,oil and gas refineries, drilling rigs, petrochemical facilities, food and beverage facilities, tunnels, outdoor wall and stanchion mounted general area lighting, and where flammable vapors, gases, ignitable dusts, fibers or flyings are present.
• Applies to hazardous locations of Zone 1 and Zone2 with explosive gas atmosphere.
• Applies to hazardous locations of Zone 21 and Zone22 with explosive dust atmosphere.

ATEX: EN IEC 60079-0-2018 ; EN 60079-1-2014; EN 60079-28-2015; EN 60079-31-2014;
IECEx: IEC 60079-0-2017; IEC 60079-1-2014; IEC 60079-28-2015; IEC 60079-31-2013;

IECEx & ATEX :

  • “CAUTION-USEFASTENER WITH YIELD STRESS ≥ 640 MPa”;
  • “WARNING – DO NOT OPEN WHEN ENERGIZED”;
  • “WARNING – DO NOT OPEN WHEN AN EXPLOSIVE ATMOSPHERE IS PRESENT”;
  • “WARNING – ONLY USE CABLES SUITABLE FOR 85°C”;
  • " WARNING - DETAILED TEMPERATURE CLASS - SEE INSTRUCTIONS”;
  • “THE FLAMPROOF JOINTS ARE NOT INTENDED TO BE REPAIRED”;
  • End user shall use certified cable gland or conduit with suitable type of protection for final installation purpose;
  • External earthing wire shall be connected when used and the cross-sectional areashall be more than 4mm2 or 10AWG;
  • Under rating condition, maximum temperature on the luminaire’s shell shall not be higher than 130℃ for T4.Temperature at cable inlet shall not be higher than allowable limit of the cable applied, to ensure the cable operation normally. The branch point is 83.6℃ and cable entry point is 69.4℃

Features

  • Industry-leading efficacy: 130lm/W±5
  • -40°C to +45°C /50°C /55°CAmbient operating temperature
  • Mounting: U-bracket
  • Wide optics for uniform illumination
  • 5 years warranty
  • Entry Size: M25Χ1.5 or NPT 3/4”-14
  • Housing –Aluminum alloy (ADC12 )
  • Lens – tempered glass
  • Beam angle: 8°, 15°, 35°, 60°, 90°, 120°

Parameters

  •  Power: 120W / 150W / 185W/ 200W / 240W
  •  Input voltage: AC100-277V, 50/60Hz
  •  Power factor: 0.97
  •  Lumen flux: 14400LM / 18000LM / 21600LM / 24000LM / 28800LM
  •  CCT: 2700K - 6500K (Optional)
  •  LEDs: 3030 
  •  LED Driver: Meanwell HLG series
  •  Dimension: 1235mm x 155mm x 148mm
  •  Weight: 19.4KG

Certificate & Standard

Have certified CES-EX-LN fixtures with the IECEX and ATEX standards for hazardous location and environments.

ATEX:
  • II 2G Ex db op is IIC T5…T6 Gb
  • II 2D Ex tb op is IIIC T94°C…T89°C …T84°C Db
  • IP66
  • Certificate No:SEV 19 ATEX 0332 X
IECEx:
  • Ex db op is IIC T5…T6 Gb
  • Ex tb op is IIIC T94°C…T89°C …T84°C Db
  • IP66
  • Certificate No:IECEx SEV 19.0039

Amounting

Versatile mounting options:

  • Flush mount
  • Swivel/surface mount
  • Pole mount
  • Mounting Angle:0°to ±90°;

 

0.6m Length, Flameproof Type, IECEx ATEX Certificated, Zone 1, Ex db op is IIC T5/T6 Gb, Zone 21, Ex tb op is IIC T94°C/T89°C/T84°C

 

Applications:

• Wastewater treatment,oil and gas refineries, drilling rigs, petrochemical facilities, food and beverage facilities, tunnels, outdoor wall and stanchion mounted general area lighting, and where flammable vapors, gases, ignitable dusts, fibers or flyings are present.
• Applies to hazardous locations of Zone 1 and Zone2 with explosive gas atmosphere.
• Applies to hazardous locations of Zone 21 and Zone22 with explosive dust atmosphere.

ATEX: EN IEC 60079-0-2018 ; EN 60079-1-2014; EN 60079-28-2015; EN 60079-31-2014;
IECEx: IEC 60079-0-2017; IEC 60079-1-2014; IEC 60079-28-2015; IEC 60079-31-2013;

IECEx & ATEX :

  • “CAUTION-USEFASTENER WITH YIELD STRESS ≥ 640 MPa”;
  • “WARNING – DO NOT OPEN WHEN ENERGIZED”;
  • “WARNING – DO NOT OPEN WHEN AN EXPLOSIVE ATMOSPHERE IS PRESENT”;
  • “WARNING – ONLY USE CABLES SUITABLE FOR 85°C”;
  • " WARNING - DETAILED TEMPERATURE CLASS - SEE INSTRUCTIONS”;
  • “THE FLAMPROOF JOINTS ARE NOT INTENDED TO BE REPAIRED”;
  • End user shall use certified cable gland or conduit with suitable type of protection for final installation purpose;
  • External earthing wire shall be connected when used and the cross-sectional areashall be more than 4mm2 or 10AWG;
  • Under rating condition, maximum temperature on the luminaire’s shell shall not be higher than 130℃ for T4.Temperature at cable inlet shall not be higher than allowable limit of the cable applied, to ensure the cable operation normally. The branch point is 83.6℃ and cable entry point is 69.4℃

Features

  • Industry-leading efficacy: 130lm/W±5
  • -40°C to +45°C /50°C /55°CAmbient operating temperature
  • Mounting: U-bracket
  • Wide optics for uniform illumination
  • 5 years warranty
  • Entry Size: M25Χ1.5 or NPT 3/4”-14
  • Housing –Aluminum alloy (ADC12 )
  • Lens – tempered glass
  • Beam angle: 8°, 15°, 35°, 60°, 90°, 120°

Parameters

  •  Power: 50W / 60W / 80W/ 100W
  •  Input voltage: AC100-277V, 50/60Hz
  •  Power factor: 0.97
  •  Lumen flux: 6000LM / 7200LM / 9600LM / 12000LM
  •  CCT: 2700K - 6500K (Optional)
  •  LEDs: 3030
  •  LED Driver: Meanwell HLG series
  •  Dimension: 617mm x 155mm x 148mm
  •  Weight: 11.4KG

Certificate & Standard

Have certified CES-EX-LN fixtures with the IECEX and ATEX standards for hazardous location and environments.

ATEX:
  • II 2G Ex db op is IIC T5…T6 Gb
  • II 2D Ex tb op is IIIC T94°C…T89°C …T84°C Db
  • IP66
  • Certificate No:SEV 19 ATEX 0332 X
IECEx:
  • Ex db op is IIC T5…T6 Gb
  • Ex tb op is IIIC T94°C…T89°C …T84°C Db
  • IP66
  • Certificate No:IECEx SEV 19.0039

Amounting

Versatile mounting options:

  • Flush mount
  • Swivel/surface mount
  • Pole mount
  • Mounting Angle:0°to ±90°;

 

Hazardous Area Lighting |  "Ex d" Type | Zone 1 Zone 21 | 100W 120W 150W 180W 200W

 

This explosion proof can be used:

  • Wastewater treatment,oil and gas refineries, drilling rigs, petrochemical facilities, food and beverage facilities, tunnels, outdoor wall and stanchion mounted general area lighting, and where flammable vapors, gases, ignitable dusts, fibers or flyings are present.
  • Applies to hazardous locations of Zone 1 and Zone2 with explosive gas atmosphere
  • Applies to hazardous locations of Zone 21 and Zone22 with explosive dust atmosphere.

 

ATEX: EN IEC 60079-0-2018; EN 60079-1-2014; EN 60079-28-2015; EN 60079-31-2014;
IECEx: IEC 60079-0-2017; IEC 60079-1-2014; IEC 60079-28-2015; IEC 60079-31-2013;

 

IECEx & ATEX :

  • “CAUTION-USEFASTENER WITH YIELD STRESS ≥ 640 MPa”;
  • “WARNING – DO NOT OPEN WHEN ENERGIZED”;
  • “WARNING – DO NOT OPEN WHEN AN EXPLOSIVE ATMOSPHERE IS PRESENT”;
  • “WARNING – ONLY USE CABLES SUITABLE FOR 85°C”;
  • " WARNING - DETAILED TEMPERATURE CLASS - SEE INSTRUCTIONS”;
  • “THE FLAMPROOF JOINTS ARE NOT INTENDED TO BE REPAIRED”;
  • End user shall use certified cable gland or conduit with suitable type of protection for final installation purpose;
  • External earthing wire shall be connected when used and the cross-sectional areashall be more than 4mm2 or 10AWG;
  • Under rating condition, maximum temperature on the luminaire’s shell shall not be higher than 130℃ for T4.Temperature at cable inlet shall not be higher than allowable limit of the cable applied, to ensure the cable operation normally. The branch point is 83.6℃ and cable entry point is 69.4℃

 

Features

  • Industry-leading efficacy: up to 130lm/W±5
  • -40°C to +45°C /50°C /55°CAmbient operating temperature
  • Mounting: U-bracket
  • Wide optics for uniform illumination
  • 5 years warranty
  • Entry Size: M25Χ1.5 or NPT 3/4”-14
  • Housing –Aluminum alloy (ADC12 )
  • Lens – tempered glass (10mm)
  • Beam angle: 120°

Parameters

  •  Power: 100W / 120W / 150W/ 180W / 200W
  •  Input voltage: AC100-240/277V, 50/60Hz
  •  Power factor: 0.97
  •  Lumen flux: 13000LM / 15600LM / 19500LM / 23400LM / 26000LM
  •  CCT: 2700K - 6500K (Optional)
  •  LEDs: 3030
  •  LED Driver: Meanwell HLG series
  •  Dimension: Φ460 x 243(287)mm
  •  Weight: 14.3KG

Certificate & Standard

Have certified CES-EX-GB fixtures with the IECEX and ATEX standards for hazardous location and environments.

ATEX:
  • II 2G Ex db op is IIC T4…T5…T6 Gb
  • II 2D Ex tb op is IIIC T103°C…T98°C …T93°C Db
  • Certify No:SEV 19 ATEX 0334 X
IECEx:
  • Ex db op is IIC T4…T5…T6 Gb
  • Ex tb op is IIIC T103°C…T98°C …T93°C Db
  • Certify No:IECEx SEV 19.0040X

Explosion Proof LED Flood Light - Zone 1 Zone 21 - 120W/150W/180W 200W - U Bracket Mount

 

Applications:
• Wastewater treatment,oil and gas refineries, drilling rigs, petrochemical facilities, food and beverage facilities, tunnels, outdoor wall and stanchion mounted general area lighting, and where flammable vapors, gases, ignitable dusts, fibers or flyings are present.
• Applies to hazardous locations of Zone 1 and Zone2 with explosive gas atmosphere.
• Applies to hazardous locations of Zone 21 and Zone22 with explosive dust atmosphere.

ATEX: EN 60079-0: 2013 ; EN 60079-7: 2015 ; EN 60079-18: 2015 ; EN 60079-28: 2015 ; EN 60079-31:2014;

Warning

  • “WARNING – DO NOT OPEN WHEN ENERGIZED”
  • “WARNING – DO NOT OPEN WHEN AN EXPLOSIVE ATMOSPHERE IS PRESENT”
  • “WARNING – ONLY USE CABLES SUITABLE FOR 85°C”
  • End user shall use certified cable gland or conduit with suitable type of protection for final installation purpose.
  • External earthing wire shall be connected when used and the cross-sectional areashall be more than 4mm2 or 10AWG.
  • Under rating condition, maximum temperature on the luminaire’s shell shall not be higher than 95℃ for T4.Temperature at cable inlet shall not be higher than allowable limit of the cable applied, to ensure the cable operation normally.

 

Features

  • Industry-leading efficacy: up to 130lm/W±5
  • -20°C to +40°C Ambient operating temperature
  • Amounting: U-bracket
  • Wide optics for uniform illumination
  • 5 years warranty
  • Entry Size: M25Χ1.5 or NPT 3/4”-14
  • Housing –Aluminum alloy (ADC12 )
  • Lens – tempered glass
  • Beam angle: 90°, 108°

Parameters

  • Power:120W/150W/180W/200W
  • Input voltage: AC100-240/277V, 50/60Hz
  • Power factor: 0.97
  • Lumen flux: 14400lm/18000lm/22200lm
  • CCT: 2700K - 6500K (Optional)
  • LEDs: 3030
  • LED Driver: Meanwell HLG series
  • Dimension: 400mm x 400mm x 169(248)mm
  • Weight: 10.5KG

Certificate & Standard

Have certified CES-J fixtures with the IECEX and ATEX standards for hazardous location and environments.

ATEX:
  • EX II 2G Ex eb mb op is IIC T4 Gb
  • EX II 2D Ex op is tb IIIC T(95°C) Db
  • IP66
  • Certify No:IEP 19ATEX 0714
IECEx:
  • Ex ec IIC T4 Gc
  • IP66
  • Certify No:IECEx UL 18.0046

Special order

  • Special Orders- Requirements
    Contact us for special requirements
    Tel: +86-755-83509822
    Fax: +86-755-83509868
    Email: This email address is being protected from spambots. You need JavaScript enabled to view it.
    Email: This email address is being protected from spambots. You need JavaScript enabled to view it.

 

 Applications:

• Wastewater treatment,oil and gas refineries, drilling rigs, petrochemical facilities, food and beverage facilities, tunnels, outdoor wall and stanchion mounted general area lighting, and where flammable vapors, gases, ignitable dusts, fibers or flyings are present.
• Applies to hazardous locations of Zone 1 and Zone2 with explosive gas atmosphere.
• Applies to hazardous locations of Zone 21 and Zone22 with explosive dust atmosphere.

ATEX: EN 60079-0: 2013 ; EN 60079-7: 2015 ; EN 60079-18: 2015 ; EN 60079-28: 2015 ; EN 60079-31:2014;

Warning

  • “WARNING – DO NOT OPEN WHEN ENERGIZED”
  • “WARNING – DO NOT OPEN WHEN AN EXPLOSIVE ATMOSPHERE IS PRESENT”
  • “WARNING – ONLY USE CABLES SUITABLE FOR 85°C”
  • End user shall use certified cable gland or conduit with suitable type of protection for final installation purpose.
  • External earthing wire shall be connected when used and the cross-sectional areashall be more than 4mm2 or 10AWG.
  • Under rating condition, maximum temperature on the luminaire’s shell shall not be higher than 95℃ for T4.Temperature at cable inlet shall not be higher than allowable limit of the cable applied, to ensure the cable operation normally.

 

Features

  • Industry-leading efficacy: up to 130lm/W±5
  • -20°C to +40°C Ambient operating temperature
  • Amounting: U-bracket
  • Wide optics for uniform illumination
  • 5 years warranty
  • Entry Size: M25Χ1.5 or NPT 3/4”-14
  • Housing –Aluminum alloy (ADC12 )
  • Lens – tempered glass
  • Beam angle: 90°, 108°

Parameters

  • Power:60W/80W/100W
  • Input voltage: AC100-240/277V, 50/60Hz
  • Power factor: 0.97
  • Lumen flux: 7200lm / 9600lm / 12000lm
  • CCT: 2700K - 6500K (Optional)
  • LEDs: 3030
  • LED Driver: Meanwell HLG series
  • Dimension: 300mm x300mm x 165(251)mm
  • Weight: 7.5KG

Certificate & Standard

Have certified CES-J fixtures with the IECEX and ATEX standards for hazardous location and environments.

ATEX:
  • EX II 2G Ex eb mb op is IIC T4 Gb
  • EX II 2D Ex op is tb IIIC (T95°C) Db
  • IP66
  • Certify No:IEP 19ATEX 0714
IECEx:
  • Ex ec IIC T4 Gc
  • IP66
  • Certify No:IECEx UL 18.0046

Special order

  • Special Orders- Requirements
    Contact us for special requirements
    Tel: +86-755-83509822
    Fax: +86-755-83509868
    Email: This email address is being protected from spambots. You need JavaScript enabled to view it.
    Email: This email address is being protected from spambots. You need JavaScript enabled to view it.

Applications:

• Wastewater treatment,oil and gas refineries, drilling rigs, petrochemical facilities, food and beverage facilities, tunnels, outdoor wall and stanchion mounted general area lighting, and where flammable vapors, gases, ignitable dusts, fibers or flyings are present.
• Applies to hazardous locations of Zone 1 and Zone2 with explosive gas atmosphere.
• Applies to hazardous locations of Zone 21 and Zone22 with explosive dust atmosphere.

ATEX: EN 60079-0: 2013 ; EN 60079-7: 2015 ; EN 60079-18: 2015 ; EN 60079-28: 2015 ; EN 60079-31:2014;

 

Warning

  • “WARNING – DO NOT OPEN WHEN ENERGIZED”
  • “WARNING – DO NOT OPEN WHEN AN EXPLOSIVE ATMOSPHERE IS PRESENT”
  • “WARNING – ONLY USE CABLES SUITABLE FOR 85°C”
  • End user shall use certified cable gland or conduit with suitable type of protection for final installation purpose.
  • External earthing wire shall be connected when used and the cross-sectional areashall be more than 4mm2 or 10AWG.
  • Under rating condition, maximum temperature on the luminaire’s shell shall not be higher than 95℃ for T4.Temperature at cable inlet shall not be higher than allowable limit of the cable applied, to ensure the cable operation normally.

 

Mounting:

Fix 2 M10 screws on the wall according to the distance between the holes of the bracket. Install the bracket on the screws and then fasten it with the nut. Fix the position of the lamp Place the lamp cord into the pole; connect the wire to local power supply (AC100-277V).

explosion proof floodlight installation

explosion proof floodlight M25 entry size

Features

  • Industry-leading efficacy: up to 130lm/W±5
  • -20°C to +40°C Ambient operating temperature
  • Amounting: U-bracket
  • Wide optics for uniform illumination
  • 5 years warranty
  • Entry Size: M25Χ1.5 or NPT 3/4”-14
  • Housing –Aluminum alloy (ADC12 )
  • Lens – tempered glass
  • Beam angle: 90°, 108°

Parameters

  •  Power:20W/30W/40W
  •  Input voltage: AC100-240/277V, 50/60Hz
  •  Power factor: 0.97
  •  Lumen flux: 2400lm / 3600lm / 4800lm
  •  CCT: 2700K - 6500K (Optional)
  •  LEDs: 3030
  •  LED Driver: Meanwell HLG series
  •  Dimension: 200mm*200mm*147mm
  •  Weight: 4KG

Certificate & Standard

Have certified CES-J fixtures with the IECEX and ATEX standards for hazardous location and environments.

ATEX:
  • EX II 2G Ex eb mb op is IIC T4 Gb
  • EX II 2D Ex op is tb IIIC T(95°C) Db
  • IP66
  • Certify No.:IEP 19ATEX 0714
IECEx:
  • Ex ec IIC T4 Gc
  • IP66
  • Certify No:IECEx UL 18.0046

Special order

  • Contact us for special requirements
    Tel: +86-755-83509822
    Fax: +86-755-83509868
    Email: This email address is being protected from spambots. You need JavaScript enabled to view it.
    Email: This email address is being protected from spambots. You need JavaScript enabled to view it.

In a dark environment or in a smoky dangerous area or harsh environment, ordinary mobile lighting products have many problems, such as insufficient exposure distance, poor penetration, low explosion-proof level, etc. These problems cause great difficulties in the rescue process. , It will cause immeasurable losses invisibly.

Portable explosion-proof lighting

In this regard, CESP discovered and solved problems based on market research and communication with front-line users. According to these problems, we designed many styles of explosion-proof lighting fixtures, including explosion-proof headlights, explosion-proof flashlights, portable explosion-proof work lights, explosion-proof signal lights, etc. .

These explosion-proof lighting products can be used for firefighting, electric power, industrial and mining enterprises and other flammable and explosive places to provide mobile lighting. They are very suitable for various field operations, such as: geological exploration, tourism exploration, border patrol, coastal defense patrol, rescue and disaster relief, field operations, Tunnel operations, airport inspections, railway inspections, archaeology and fire command, criminal investigation, traffic accident handling, power emergency repairs and other lighting needs.

  • Imported high-hardness carbon fiber composite material + die-cast aluminum to ensure that the product can withstand strong collisions and impacts, high and low temperatures, dust and corrosion
  • Heavy-protection, high-energy, non-memory lithium battery, large capacity, long life, high number of recharges, low self-discharge rate, economical and environmentally friendly, and can prevent overcharge, overdischarge, short circuit, etc.
  • Intelligent control: Our mobile explosion-proof lighting products have a variety of working methods, and the lighting methods can be changed at will, such as: emergency flashing light, remote floodlight, warning light, etc., working modes: strong light, working light, stroboscopic .
  • Intrinsically safe explosion-proof design, suitable for various flammable and explosive places in Zone 1 and Zone 2
  • Professional sealed design fire-fighting equipment with the highest protection level above IP66
  • Many humanized designs of large handle, large switch, power display and direction indicator light provide more convenience for use
  • Diversity There are many different types of mobile explosion-proof products to choose from below,

 

Applications:

  • Safe and reliable: flameproof + intrinsically safe explosion-proof design, suitable for various flammable and explosive places in Zone 1 and Zone 2.
  • Excellent energy efficiency: LED light source adopts world-renowned brands, comes with two 12w imported LED light sources, and the color temperature of cold and warm light can be switched and controlled.
  • Economical and environmentally friendly: dual-protection high-energy non-memory lithium battery, large capacity, long life, high recharge times, low self-discharge rate, economical and environmentally friendly, and can prevent overcharge, overdischarge, short circuit, etc.
  • Light weight and strong durability: small size, light weight, reasonable structure and beautiful appearance. It can be held in hand, leaned against, suspended, etc. to meet various work needs.
  • Waterproof and drop-proof: The company's product shell adopts imported high-hardness carbon fiber composite material to ensure that the product can withstand strong collisions and impacts, high and low temperatures, dust and corrosion. Suitable for use in extreme environments and climatic conditions.

Mobile Lighting for Heavy Duty (Long Time)

     With the continuous improvement of emergency rescue safety requirements in the petroleum and chemical industries, mobile emergency rescue lamps not only need to be carried and transported over long distances, but also suitable for the construction, maintenance and emergency lighting of flammable and explosive places such as oil refining and chemical industries. In harsh natural environments, the height and irradiation angle must be flexibly adjusted during use. In addition, it needs to be charged to meet long hours of work.

     CESP launched the CES-FL series, which is lightweight, portable, multi-functional, high-protection, and long-lasting. This series has been used in many occasions such as flood fighting and disaster relief.

 

 

 

Feature:

  • Excellent energy efficiency: high brightness, lamp luminous flux>4000lm, 6m center illuminance (Spotlight)>1000lx, 3m average illuminance (floodlight)>200lx.
  • Lightweight and portable: small size, light weight, can be hand-carried or carried. The lamps can also be installed with track wheels to facilitate users to move on the railway monorail;
  • Multifunctional: The lamp has multiple functions and is user-friendly. It integrates functions such as concentrated light/flood light, power display, stepless dimming, and signal alarm to meet the needs of users in different environments. The standard USB charging interface can be used to charge most mobile phones and other digital products, and solve the problem that users cannot use mobile phones and other digital products when the power is exhausted when operating outdoors;
  • Continuous lighting: long running time, strong light discharge time>10h, working light discharge time>16h, meeting the long-duration requirements of night construction lighting.
  • Multiple modes: a variety of lighting output levels, with spotlight, floodlight and super light modes, as well as red and blue warning lights to meet the lighting needs of different places.
  • High explosion-proof effect: It can be safely used in various flammable and explosive places.
  • High protection: high protection, the overall protection level of the lamp is IP66, resistance to 1m drop, and can be used reliably in various rain and snow environments.
  • Flexible and convenient: flexible and convenient, the lamp head can be rotated 360 degrees horizontally and adjusted 135 degrees vertically, so that the lamp has the ability to provide lighting in any direction.